EcoQuest MI-1500B Скачать руководство пользователя страница 5

ADJUST/SETTING CONTROLS

Ionizer Control --

The adjustment and setting of the ionizer control for the MI-1500B 

ranges from full positive to full negative and is determined by ap-

plication. The more particulate or pollutant in the air, the higher the 

settings need to be. The MI-1500B is capable of creating a static 

charge on objects. Locate a setting where the pollutants or par-

ticulates are eliminated and still have a non-static situation.

Fan Control --

The fan speed is adjustable for the MI-1500B

Static Control --

Static is created by an electrical imbalance between positive and 

negative ions and can be biased positively or negatively. Estab-

lishment of the stronger polarity can be determined by a trails 

an error method; however, the majority of all static problems are 

positive in nature. This means that the best starting point for the 

ionizer setting is at the one oʼclock position, which is a  slightly 

negative position. If the static problem becomes worse, turn the 

control to the left in small increments until the problem has been 

resolved. If the static problems has been reduced, but not elimi-

nated, turn the control to the right in small increments until the 

problem is resolved.

Warning --

The MI-1500B can create a high level of static electricity in an 

unpolluted environment which may cause problems with static 

sensitive equipment, such as computers.

Smoke, Dust, and Particulate Remove --

Airborne contaminates are best removed with the ionizer control 

set to the extreme right (full negative). Depending upon the nature 

and degree of the pollution, it may not be necessary to have the 

control at full power.

Содержание MI-1500B

Страница 1: ...eneville TN 37743 423 638 7246 OWNERS MANUAL EcoQuest Electronic Air Purification Systems MODEL MI 1500B Pre Installation Operation Maintenance Replacement Parts Warranty Caution Read manual carefully for proper procedures and operation ...

Страница 2: ...G FEATURES 2 MODEL SPECIFICATION 2 INSTALLATION 2 PRINCIPLES OF OPERATION 3 PLACING THE UNIT 3 ADJUST SETTING THE UNIT CONTROLS 4 APPLICATIONS 5 MAINTENANCE AND TROUBLESHOOTING 5 REPLACEMENT PARTS 5 WARRANTY INFORMATION 5 ...

Страница 3: ...120 volt 60 hz AC line operation or 220 volt 50 60 hz AC line operation Less than 150 watts power consumption 26 kv DC ion generator Mechanical 3000 CFM adjustable free air delivery fan Dimensions Weight 28 height x 26 width x 18 depth 55 lbs INSTALLATION AND INSPECTION Remove unit from shipping carton Remove all protective materials Check for shipping damage or loose broken parts Plug the unit in...

Страница 4: ...charged precipitated together and then adhere to a grounded surface or are made heavy enough to be influenced by gravity PLACING THE UNIT Elevate the unit as high as possible to insure complete purifica tion Some pollutants such as smoke rise and the unit when elevated can more effectively eliminate the pollutant The EcoQuest MI 1500B is most effective when placed in a posi tion that allows the ions...

Страница 5: ...ls an error method however the majority of all static problems are positive in nature This means that the best starting point for the ionizer setting is at the one oʼclock position which is a slightly negative position If the static problem becomes worse turn the control to the left in small increments until the problem has been resolved If the static problems has been reduced but not elimi nated ...

Страница 6: ...where it may be necessary to give it a gentle push the first time it is used If the fan squeaks a few drops of light weight oil may be needed on the fan shaft TROUBLESHOOTING 1 Is the unit plugged in 2 Are you sure the outlet is active 3 Is the unit off on switch activated 4 Check the fuse See Warranty Card Please record the serial number of your EcoQuest MI 1500B Serial ___________________________...

Страница 7: ...APPLICATIONS Smoke Agricultural Dust Airborne Bacteria Plastic Operations Saw Dust Dust Bars Bingo Animal Dander Feather Dust Printing Areas Paper Handling Many Others ...

Страница 8: ......