Specifications

Living Water II

Flow Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1/2 gallon/minute (2 Liters/minute)
Min. Operating Pressure. . . . . . . . . . . . . . . . . . . .  15 psi  (105kPa)
Max. Operating Pressure  . . . . . . . . . . . . . . . . . . .  100 psi (609kPa)
Water Temp.  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  40 – 100 F (5 – 38 C)
Electrical Requirements . . . . . . . . . . . . . . . . . . . .  20 watts, 50 – 60 Hz, 110 or 230 volts

Filter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Activated Carbon Block with lead  
 

Adsorbent media

Particulate Reduction  . . . . . . . . . . . . . . . . . . . . . .  0.5 micron nominal
Filter Life  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1 year or 1000 gallons (4,000 Liters)
Chemical Additives  . . . . . . . . . . . . . . . . . . . . . . . .  None
UV Lamp Life  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10,000+ on/off cycles (approx. 2 years)
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7.5 x 13 x 4 in. (19 x 33 x 10 cm)

Dry Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6 lbs. (2.75 kg)

Living Water III

Same as above except
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11 x 13 x 4 in. (28 x 33 x 10 cm)
Dry Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8 lbs. (3.65 kg)

This Class B system conforms to NSF/ANSI 55 for the supplemental bactericidal 
treatment of disinfected public drinking water or other drinking water which has 
been tested and deemed acceptable for human consumption by the state or local 
health agency having jurisdiction.  The system is only designed to reduce normally 
occurring non-pathogenic microorganisms.  Class B systems are not intended for 
disinfection of contaminated water.

System conforms to NSF/ANSI 42 for the specific performance claims as verified and 
substantiated by test data.

Changing the UV Lamp

It is recommended that you contact your authorized Living Water distributor to replace 
the UV lamp when it is no longer working, or every two years.

WARNING: To prevent electrical shock, unplug the power supply from the electrical 
outlet. DO NOT PROCEED BEFORE MAKING SURE THERE IS NO ELECTRICITY  
GOING TO THE SYSTEM.

1. Disconnect the tubing from the top and bottom of the system. Remove the unit from 

the wall mounts if applicable. Lay the system down horizontally.

2. Using a Phillips head screwdriver, remove the four (LWII) or six (LWIII) screws located 

on the bottom of the unit.

3. Slide the bottom cup off the unit.

4. Remove the screw (A) and the retainer wire (B)

5. Disconnect the two wire connectors (C) and (D) coming 

from the lamp and gently slide the lamp out of the system.

6. Carefully slide the replacement UV lamp into the system 

holding it by the ceramic base only. Reconnect the two wire connectors (C) and (D).

NOTE: Touching the glass portion of the bulb will leave an oil deposit and may cause 
the bulb to fail prematurely. If you should inadvertently touch the glass, clean the 
entire bulb surface using denatured alcohol before installing.

7. Reinstall the retainer wire (B) back into its original position and tighten screw (A).

8. Replace the bottom cup and secure with screws. 

9. Remount the system, reconnect the tubing and plug in the power adapter.

If the lamp does not illuminate, contact your authorized EcoQuest Business Owner. 
Do not use the system until the lamp is functioning properly. If you do not have an 
EcoQuest Business Owner, contact EcoQuest directly at 800.989.2299.

A

B

C

D

5

6

Содержание Living Water IIs CT

Страница 1: ...ion Operation Maintenance Changing the Filters Changing the UV Lamp Specifications Warranty 65 00137 004 LW_OM_ENG_01007 Rev 0107 EcoQuest International 310 T Elmer Cox Drive Greeneville TN 37743 800 989 2299 ADVANCED WATER TREATMENT SYSTEMS Living Water IIs CT Countertop Living Water IIIs CT Countertop ...

Страница 2: ...nfection before or after the system System and installation must comply with local state regulations Installation of Countertop Models CT Living Water IIsCT and IIIsCT all come ready to install to most faucets Installation takes just a few minutes and requires a pair of pliers NOTE The unit must be installed vertically not horizontal WARNING Remove protective packaging from inside the UV lamp hous...

Страница 3: ...and return the treated water out of the small spigot Once the filter chambers are filled the UV lamp will activate automatically and water will flow from the bottom to the top of the system in a swirling action CAUTION If the water flows from the top of the system to the bottom the hose connections are reversed See page 2 for correct hose installation instructions IMPORTANT If the diverter pin doe...

Страница 4: ... UV lamp when it is no longer working or every two years WARNING To prevent electrical shock unplug the power supply from the electrical outlet DO NOT PROCEED BEFORE MAKING SURE THERE IS NO ELECTRICITY GOING TO THE SYSTEM 1 Disconnect the tubing from the top and bottom of the system Remove the unit from the wall mounts if applicable Lay the system down horizontally 2 Using a Phillips head screwdri...