Страница 1: ...OWNERS MANUAL Installation Operation Specifications Features Maintenance Warranty ...

Страница 2: ......

Страница 3: ...e this unit without the rear lint screen AND back cover installed CAUTION Disconnect power cord before servicing Location for Protective Earth Line 100 110 volt models use 1 6 Amp slow blow fuse 220 240 volt models use 1 0 Amp slow blow fuse CONTENTS Specifications 4 Introduction 4 Your New Fresh Air by EcoQuest 5 Inspection Installation 5 Unit Features 6 Operation 7 Settings and Adjustments 8 Pla...

Страница 4: ...ecord the serial number of your Fresh Air by EcoQuest Serial ______________________________________________ Electrical 100 volt 50 60hz 110 volt 60 hz 220 240 volt 50 60 hz depending on model 90 watts power consumption 24 to 30 KV 20 30 Khz ion generation pulsator Fixed 6 KV DC needle ion generator Mechanical 70 100 CFM fan output Actual CFM will vary depending on condition of rear lint screen Siz...

Страница 5: ...y should look similar to below INSPECTION INSTALLATION YOUR NEW FRESH AIR BY ECOQUEST Eliminates smoke odors and tobacco smoke Includes Certified Space Technology Radiant Catalytic Ionization RCI which incorporates the same process NASA uses to scrub the air inside spacecraft Germicidal broad spectrum high intensity UVX lamp 100 300 nm helps kill airborne germs as they pass through the unit Remove...

Страница 6: ...Display Main Power Switch Fuse Power Cord Receptacle Controls Removable Grill UNIT FEATURES Away Mode Function w adjustable digital timer IntelliAir Maintenance Reminders IntelliAir Service Alerts Remote Control or Manual Operation Computer style cord Uses Standard household current Washable Purification Plate Washable Rear Lint Screen Replaceable RCI cell Removable Front Grill ...

Страница 7: ... button until the desired time is reached 2 4 6 or 8 hours The unit will display AWAY MODE and the remaining time To interrupt the AWAY MODE press the Normal High button Please note unoccupied areas includes pets Some pets like humans may experience adverse reactions from exposure to increased levels of ozone and should not be present during AWAY MODEoperation Sanitize Mode Fan Speed Max AWAY MODE...

Страница 8: ... Mode ON SET OFF Battery compartment 2 AAA Normal High Purifier DOWN Purifier UP Fan UP Fan DOWN Power ON OFF Fan UP Away Mode ON SET OFF Purifier UP Purifier DOWN Fan DOWN Normal High Reminder Reset If you are operating your central heating and air conditioning fan or other ventilation system continuously set the coverage up to the total ventilated indoor area otherwise set the coverage up to the...

Страница 9: ...r the indoor area The level is indicated by both a horizontal bar graph and square footage U S models or square meters international models The unit will switch to Normal Mode if the PURIFIER DOWN button is pressed when the square footage is set to 250 ft2 23 m2 AWAY MODE Turns on and adjusts the timer for the AWAY MODE function Each press of the Away Mode button will increase the time by two hour...

Страница 10: ...n of ions To prevent injury be sure the power cord is not accessible to small children LCD SCREEN The LCD Screen is used to display all current settings see page 5 as well as any maintenance reminders and service messages LCD DISPLAY LCD SCREEN BACKLIGHT As adjustments are being made the LCD screen backlight will brighten and the settings on the screen will change After 3 seconds without change th...

Страница 11: ... the Reminder Reset button and the screen will momentarily display CLEARED to let you know the reminder has been cleared All the other service reminders will clear automatically once the unit has been turned off and back on and the problem has been corrected PERFORM CLEANING approx every 30 days Clean the rear lint screen see page 12 Vacuum the RCI cell Clean purifier plate see page 12 Vacuum fron...

Страница 12: ...ills periodically to remove any lint buildup CLEANING THE RCI CELL Remove the RCI cell and carefully vacuum accumulated lint Do not wash the RCI cell damage from water may result REAR LINT SCREEN CLEANING You have two options to clean the rear lint screen 1 When visibly dirty simply remove the rear lint screen from the unit see pages 14 17 and with a hand held vacuum remove the heavy particulate T...

Страница 13: ...the plate to soak for no more than 10 minutes CAUTION Damage may result from soaking the purifier plate longer than 10 minutes Remove plate and scrub with a soft bristle brush Rinse thoroughly Let air dry for 24 hours or use a blow dryer to dry thoroughly The unit will display a REPLACE PLATE message if the purification plate needs to be replaced 100 110 volt models use 1 6 Amp slow blow fuse 220 ...

Страница 14: ...3 Remove back cover 4 Remove two 2 screws securing the top of the lint screen WARNING DO NOT OPERATE Fresh Air by EcoQuest without the rear lint screen and back cover properly installed 5 Remove the lint screen by pulling back the top then lifting up and out To remove the purification plate continue to step 6 To remove the RCI cell skip to step 7 For installation of the lint screen go to page 16 ...

Страница 15: ...ge 8 for complete cleaning instructions 6 6 To remove the purification plate grasp edge of plate in the center and gently pull out NOTE If the plate is difficult to remove gently press down on the lower metal contact tab DISPOSAL OF A USED RCI CELL Please do not throw a used RCI cell into the garbage The special germicidal UVX bulb used in the RCI cell contains a very small amount of mercury You m...

Страница 16: ...slotted protrusions at the rear of the plate cage and that the angle brackets and studs are correctly aligned 3 3 Insert the RCI cell connector into the plug on the plate cage Press the connector firmly until the two tabs lock into place INSTALLING THE RCI CELL PURIFIER PLATE 4 4 Gently insert the purifier plate between the guides inside the cage until it stops To Install Rear Lint Screen follow s...

Страница 17: ...ear lint screen inserting the bottom of the lint screen first Note The bottom of the rear lint screen is held into place by two alignment guides see inset 10 10 Replace two 2 back cover screws 9 9 Replace the back cover WARNING DO NOT OPERATE Fresh Air by EcoQuest without the rear lint screen and back cover properly installed For disassembly instructions see pages 14 15 ...

Страница 18: ...ing power to the unit Make sure the rear lint screen and back cover are properly installed The tab on the back cover must depress the safety switch inside the unit see inset Check to see if the proper fuse is installed and that it is operational Rear safety switch location If you are operating your central heating and air conditioning fan or other ventilation system continuously set the coverage u...

Страница 19: ...from your EcoQuest Dealer The electrical stainless steel contacts are not contacting the screen portion of the purifier plate Unplug and inspect the unit for any loose connections Do not attempt to disassemble the unit this will void the warranty of the product 3 The Purifier Plate is making a noise has a burning smell and or appears to arc or spark What is the problem The purifier plate is most l...

Страница 20: ...smoke and or particulate remain within the environment Problem Lack of ionization and or air movement 6 Air flow is restricted or reduced Is the unit properly placed away from objects that may obstruct air flow Are the rear lint screen back cover and front grill clean Is the RCI cell clean 7 How can I tell if the RCI cell is functioning The RCI cell will produce a glow that is visible through the ...

Страница 21: ...ocated on the front of the manual or visit www EcoQuest com for additional support This product is of solid state construction and is warrantied by EcoQuest International 310 T Elmer Cox Drive Greeneville TN 37743 to the original purchaser depending on model to be free from defect in materials and workmanship for a limited time Length of warranty will vary depending on model See warranty card for ...

Страница 22: ... equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television which can be determined by turning the equipment ...

Страница 23: ......

Страница 24: ... EcoQuest International EcoQuest International Healthy Living Technologies and Fresh Air by EcoQuest Logo are Registered by EcoQuest International Did you forget to register your Fresh Air by EcoQuest By registering you ll activate your warranty and your privacy is guaranteed Just fill out your warranty card and drop it in the mail 65 00162 001 REV 03_05 FA 2 0 OM ...