Ecopower Heating VANTAGE NEHV06 Скачать руководство пользователя страница 16

16

TABLE OF TECHNICAL FAULTS

PROBLEM

STATE OF THE 

RADIATOR

PROBABLE CAUSE

SOLUTION

Radiator is not working 

properly

“ALL” is displayed

The temperature 

sensor is faulty

Contact a Service 

Centre

The radiator does not 

heat up

The display does not 

show any notice

No power supply

Check the presence of 

mains voltage

Any

Malfunction of resistor 

or adjustment board

Contact a Service 

Centre

The radiator does not 

ensure to reach the 

desired temperature in 

the room

Properly working

The radiator power is 

insufficient to meet the 

need of the room

Replace the radiator 

with a more powerful 

one or add another 

radiator.

Properly working

The radiator position 

affects excessively the 

temperature detected 

in the room

Relocate the radiator

The symbol 

 is not 

displayed and the 

radiator is cold or 

lukewarm.

The temperature 

set is lower than the 

temperature of the 

room.

Increase the 

temperature set.

The symbol 

 is 

displayed

"Child protection" 

function is selected, 

the radiator output is 

lower than nominal 

one.

Deactivate "Child 

protection" function 

as shown in the proper 

section of the manual.

Expansion noises in 

switching on and/or off 

phase

Any

Radiator supporting 

brackets are not 

centred and scrape on 

the radiator.

Position brackets 

properly.

The radiator leaks oil

Any

Defect of the heating 

body or lack of sealing 

in connectors.

Contact a Service 

Centre.

Window opening 

detection does not 

work properly

The symbol 

 is not 

displayed

"Window opening" 

function is not enabled.

Enable the function 

as per the specific 

paragraph of this 

instruction manual

The symbol 

 is 

displayed

Lowering of 

temperature in 

the rooms has not 

exceeded 5°C in the 

time provided or 

the position of the 

radiator does not allow 

the probe to detect the 

temperature correctly.

Relocate the radiator.

Содержание VANTAGE NEHV06

Страница 1: ...IST 03 F 079 01 Electric Heating Expert Gateway House Kings Parade Kings Road Fleet Hampshire GU51 3AB Phone number 01252 560770 Website www electricheatingexpert co uk ...

Страница 2: ...manual TABLE OF CONTENTS 1 WARNINGS Page 3 2 ELECTRICAL CONNECTIONS Page 4 2 1 DETAILS ON INSTALLATION IN THE BATHROOM Page 4 3 INSTALLATION OF THE APPLIANCE Page 5 3 1 RADIATOR WALL MOUNTING Page 6 4 ADJUSTMENT AND PROGRAMMING Page 9 4 1 CONTROL PANEL Page 9 4 2 USER FUNCTIONS Page 10 4 2 1 DESCRIPTION OF FUNCTIONS Page 11 4 3 USE OF THE RADIATOR Page 14 4 3 1 SETTING OF CURRENT DAY AND TIME Page...

Страница 3: ...er the age of 3 must be kept away from the appliance unless they are supervised Children aged between 3 and 8 can only turn the radiator on or off provided that it is positioned properly and that children have been taught the safe use of the appliance and have understood the possible correlated risks Children aged between 3 and 8 cannot connect the appliance to the power outlet cannot adjust or cl...

Страница 4: ... the appliance is protected by a high sensitivity differential protection device Do not introduce and do not try to penetrate with metal objects into the side of the radiator containing the adjustment electrical system right side If the power cable is damaged it must be replaced only by a qualified electrician 2 1 DETAILS ON INSTALLATION IN THE BATHROOM Installation must be compliant with the stan...

Страница 5: ...radiator if possible under a window or near areas with high heat loss of the room to heat The radiator must not be installed in a niche or under a power outlet Curtains furniture or other objects that may obstruct the correct heat distribution must be placed at a minimum distance of 50 cm from the front of the radiator Respect a distance of at least 120 mm from the lower edge of the radiator and t...

Страница 6: ...fastened to a wall through the suitable mounting brackets provided with the product The fastening system is composed of Using adhesive tape stick the template supplied in the desired position and mark the position of the holes then remove the template ...

Страница 7: ...500 W 12 1800 W DIMENSION A 239 mm 319 mm 558 mm 558 mm 797 mm 1 1 Drill as indicated by the holes marked and then insert the blocks in the wall 2 Insert the 4 screws without tightening them put the two A brackets in place and then tighten the screws Electric Heating Expert Gateway House Kings Parade Kings Road Fleet Hampshire GU51 3AB Phone number 01252 560770 Website www electricheatingexpert co...

Страница 8: ... the bracket 4 Fit the two c lower clamps and rotate them until you hear a first click Electric Heating Expert Gateway House Kings Parade Kings Road Fleet Hampshire GU51 3AB Phone number 01252 560770 Website www electricheatingexpert co uk ...

Страница 9: ...The operation is over only when locking hooks are blocked and the radiator is fixed on the wall without any possibility of movement In any case the minimum distance of the radiator from the floor must be 120 mm 4 ADJUSTMENT AND PROGRAMMING 4 1 CONTROL PANEL The appliance is equipped with five keys as shown in the figure decrement key increment key Function key selection of operating modes Standby ...

Страница 10: ...rotection Holiday Programming Boost Eco Standby It is possible to switch from an operating mode to another by pressing the Function key Special functions are the following Window opening detection Heating on Programming Standby Freeze protection Night Comfort Holiday Pilot wire Temperature and time Days of the week Energy consumption indication Key lock Check of surface temperature Start up adapti...

Страница 11: ...splayed 2 Select the night temperature using and keys The maximum value that can be set is equal to the comfort temperature minus 0 5 C The minimum value is 7 C Freeze protection mode By selecting this mode the ambient temperature is set to 7 C Press the Function key until the relevant key is displayed Holiday mode By selecting this function the radiator enters in freeze protection mode for a peri...

Страница 12: ...on key as many times as necessary until the relevant icon is displayed Window opening function The radiator is able to identify whether a window has been opened through detection of a quick ambient temperature reduction 5 C at least in a maximum of 30 minutes If this happens the radiator switches off for 30 minutes and then it restarts working in the previously set mode if it detects a subsequent ...

Страница 13: ...ept Child protection function This function when selected reduces the radiator power and reduces the radiator surface temperature accordingly then it can be useful in the presence of children Moreover this function allows to use the same radiator also in rooms smaller than those to which it was initially intended without too frequent ambient temperature variations comfort improvement When this fun...

Страница 14: ...gment bar indicates the set temperature level The higher the set temperature more segments are on This is an immediate visualisation of consumption required since the higher the temperature set the higher of course the energy consumption Please note that a correct room temperature is between 20 and 21 C Temperature ranges associated with segments are Number of segments on Temperature range in C 1 ...

Страница 15: ... the display or the night temperature level short bar in the lower part of the display of day 1 Monday 6 Press Function key to confirm the programming selection of the first day day 1 Monday 7 Repeat the same procedure for programming the remaining days from 2 to 7 Now the weekly programming is set and remains stored as P3 parameter and can be changed by repeating the operation described above Not...

Страница 16: ...s cold or lukewarm The temperature set is lower than the temperature of the room Increase the temperature set The symbol is displayed Child protection function is selected the radiator output is lower than nominal one Deactivate Child protection function as shown in the proper section of the manual Expansion noises in switching on and or off phase Any Radiator supporting brackets are not centred a...

Страница 17: ...he Fondital radiators are produced with an identification label that ensures traceability Such label certifies compliance with EEC directives and with electrical regulations Colour of the radiator RAL 9010 8 ENVIRONMENT The symbol applied to the appliance and shown here indicates that the product must be disposed of in separate collection for electrical equipment At the end of the life of the appl...

Страница 18: ...n class IP24 Working temperature 0 50 C Consumption in standby mode 0 5 W Storage temperature 20 70 C Working relative humidity 0 85 non condensing Type of setting Integral proportion Temperature range 7 C 32 C Electric Heating Expert Gateway House Kings Parade Kings Road Fleet Hampshire GU51 3AB Phone number 01252 560770 Website www electricheatingexpert co uk ...

Страница 19: ...ettiva 2002 96 EC WEEE Direttiva 2009 125 EC Eco design Regolamento Europeo 1275 2008 and in accordance with rules EN 60335 1 2012 EN 60335 2 30 2011 EN 60335 2 30 2011 A11 EN 55014 1 2008 EN 55014 2 1998 EN 61000 3 2 2004 EN 61000 3 3 2004 EN 61000 4 2 2009 EN 61000 4 4 2005 EN 61000 4 5 2006 EN 61000 4 6 2009 EN 61000 4 11 2004 EN 62233 2008 30 06 2015 10 DECLARATION OF CONFORMITY Electric Heati...

Страница 20: ...The manufacturer reserves the right to modify the products as it deems necessary and useful without affecting their basic features IST 03 F 079 01 Luglio 2015 07 2015 0ZLIBIST87 ...

Отзывы: