Ecoplus ZR9W Series Скачать руководство пользователя страница 7

air from 
outside

Low Temp.

fins heat

exchanger

3).Working principle

Hot water 

Compressor

Capillary

Compressor

         Water tank

the inner of hot water units) 

Water heat
exchanger

Cold water

5

2.SPECIFICATION

Hot water outlet
                

Cold 

Water supply

Mixture control valve

Φ150

 Fan drift

Φ150

 Fan drift

Cold water inlet

Single way valve

Draining outlet

 

Safety valve

Internal coil

Air inlet

Air outlet

High pressure switch

Low pressure switch

Compressor

Temp. Sensor 
for outlet water

4).

Heat pump sketch map

1   Water tank, heat exchanger specifications.
    a. Water tank volume: 200L/250L/300L/400L
    b. Hot water side Heat exchanger type: coil heat exchanger
    c. Hot water side Heat exchanger material: aluminium
    d. Air source side heat exchanger: pipes with Finned , 3 lines
    e. Air source side heat exchanger: copper, aluminium
2  Brief description of the heat pump ON/OFF, for example,
    Users can use the controller to adjust the parameter " 1.1" in 
    order to set the target outlet water temperature. When it 
    sensors the actual water temp is lower than the target by 5  C, 
    the machine start to run. The heat pump transfers the heat of 
    air into the water tank, makes the water temp raised. When 
    the sensor sensors the actual water temp is higher(or equal) to 
    the target, the machine stops. The heating has been finished. 
    There is 200L/250L/300L /400Lhot water to be used.   
3  There should have installed a 0.7Mpa single pressure release 
    valve when install the heat pump. See Fig.
4  Lowest inlet water temp for normal working(initial water 
    temp): 7  C. 
5. Please install a air duct pipe of 2-3 meter to air outlet on top 
    of the heat pump .

REMARK:

Содержание ZR9W Series

Страница 1: ...DOMESTIC HOT WATER UNIT STATUS Heating Outlet water temp 31 Target temp 57 24 06 2011 09 28...

Страница 2: ...tion 3 4 5 2 Appearance and Features 3 Working principle 3 6 5 Dimensions 7 7 7 3 Controller Introduction 7 Appendix 16 17 6 Maintenance 16 4 Installation Instruction 5 Trial Running 14 15 1 Functions...

Страница 3: ...ater range 12 60 the pressure of water 0 1MPa 0 7MPa 5 If the power cord is damaged please replace a new one offered from factory by professional technicians 6 Power plug s rated current shall be in a...

Страница 4: ...al transport For the manual transport the wooden pallet can be used for bottom part Using ropes or carrying straps a second or third handling configuration is possible With this type of handling care...

Страница 5: ...tlet water temperature Max outlet water temperature Air volume Air pressure Duct diameter Noise Water inlet size outlet size Net dimensions Package dimensions Net weight Gross weight Compressor type 2...

Страница 6: ...e g a solar heating system or a boiler Dehumidification in the recirculating air mode Dehumidified air in the laundry room supports laundry drying and prevents moisture induced damage Cooling in the...

Страница 7: ...ce side heat exchanger pipes with Finned 3 lines e Air source side heat exchanger copper aluminium 2 Brief description of the heat pump ON OFF for example Users can use the controller to adjust the pa...

Страница 8: ...er inlet Circulation water outlet Draining outlet 6 2 SPECIFICATION M N 35mm TYPE SIZE B A C D F E G T M V N P H 1650 1185 1025 450 250 32 5 450 925 1025 1135 925 40 560 ZR9W 200V 1535 1070 910 640 45...

Страница 9: ...rget temp 55 24 06 2011 09 28 STATUS Heating Outlet water temp 31 Target temp 55 24 06 2011 09 28 Power Menu Escape Operation Instruction All parameter settings can only be adjusted setted under stand...

Страница 10: ...ect Unit status Aux heating Off Fan mode On Press button to access the Main Menu see Fig 4 Press to enter FIG 5 interface for changing the setting of Aux Heating and Fan Mode function You may change s...

Страница 11: ...8 Press or to change the parameter value then press ESC to confirm Press ESC again to return to last interface Out water temp adjustable range 10 60 T1 heating adjustable range 2 15 Fig 6 Fig 7 Fig 8...

Страница 12: ...lue then press ESC to confirm changes press ESC to return to last interface Press or to move the cursor to ave then press to confirm and enter interface of FIG 11 Press or to choose parameter value th...

Страница 13: ...n press ESC to confirm changes press ESC to return to last interface 2 4 2 TIMER ON OFF SETTING You may set both Timer 1 and Timer 2 2 period time at the same time 2 4 2 1 TIMER 1 ON OFF SETTING Move...

Страница 14: ...the water loop 4 use new expansion valve The electronic heating temp protect 1 discharge the redundant gas 2 clean the air side heat exchanger The temp sensor is open or short circuit Check and replac...

Страница 15: ...ff Tank top temperature Tank bottom temperature Pipe temperature Evaporator temperature Ambient temperature Swell valve 10 60 C 2 15 C 30 90 C 0 90 5min 30 90 minute 30 0 C 2 30 C 1 12 Minute 0 NO 1 Y...

Страница 16: ...all power should be disconnected when servicing 8 The magnesium stick should be replaced 1 or 1 5 year according to the water quality 9 Please provide serial No on the nameplate when asking for after...

Страница 17: ...water and open the water outlet tap till water flows out 3 Make sure the water pressure is normal 0 1Mpa 0 7 Mpa 4 Check the power supply is normal or not voltage range 220v 10 5 Check if all the equ...

Страница 18: ...on reliability 4 Check whether pumps and water valves are normal working or not whether water tubing and water pipes connector are leakage or not 5 The unit and around should remain clean well ventila...

Страница 19: ...WER 1PH 220V 50Hz HIGH PRESSURE PROTECT LOW PRESSURE PROTECT FM FAN MOTOR 4 WAY VALVE FU E HEATER 3 CONTACTOR Temp sw Temp sw FU 80 Thermostat 95 Fuse protector WIRING DIAGRAM 1 COMPRESSOR LOW PRESSUR...

Страница 20: ......