air from
outside
Low Temp.
fins heat
exchanger
3).Working principle
Hot water
Compressor
Capillary
Compressor
Water tank
(
the inner of hot water units)
Water heat
exchanger
Cold water
5
2.SPECIFICATION
Hot water outlet
Cold
Water supply
Mixture control valve
Φ150
Fan drift
Φ150
Fan drift
Cold water inlet
Single way valve
Draining outlet
Safety valve
Internal coil
Air inlet
Air outlet
High pressure switch
Low pressure switch
Compressor
Temp. Sensor
for outlet water
4).
Heat pump sketch map
1 Water tank, heat exchanger specifications.
a. Water tank volume: 200L/250L/300L/400L
b. Hot water side Heat exchanger type: coil heat exchanger
c. Hot water side Heat exchanger material: aluminium
d. Air source side heat exchanger: pipes with Finned , 3 lines
e. Air source side heat exchanger: copper, aluminium
2 Brief description of the heat pump ON/OFF, for example,
Users can use the controller to adjust the parameter " 1.1" in
order to set the target outlet water temperature. When it
sensors the actual water temp is lower than the target by 5 C,
the machine start to run. The heat pump transfers the heat of
air into the water tank, makes the water temp raised. When
the sensor sensors the actual water temp is higher(or equal) to
the target, the machine stops. The heating has been finished.
There is 200L/250L/300L /400Lhot water to be used.
3 There should have installed a 0.7Mpa single pressure release
valve when install the heat pump. See Fig.
4 Lowest inlet water temp for normal working(initial water
temp): 7 C.
5. Please install a air duct pipe of 2-3 meter to air outlet on top
of the heat pump .
REMARK: