11
Replacement Part Installation Instructions
A
B
C
Страница 1: ...S 250 GPH 350 GPH 500 GPH 700 GPH 900 GPH Before operating this appliance please read this instruction manual carefully and keep it stored in safe place for future reference IMPORTANT Please read all...
Страница 2: ...tted to use this unit DO NOT let children play with this appliance Electrical Precautions and Hazards The combination of water and electricity can lead to death or severe injury from electrocution if...
Страница 3: ...operate the pump without water This will severely damage the pump 5 Do not use pump with water temperature that is higher than 100 F as it will shorten the expected life of the pump 6 Unplug power to...
Страница 4: ...Power GPH Height Max Current 120V 60 24W 250 6 0 ft 44A Accessory Specifications Accessory Specifications Part Description Thread Diameter Application 1 Screen Foam Sediment Pre Filter 3 4 inner Subme...
Страница 5: ...sible 3 3 8 Diameter Barbed Outflow Fitting 1 2 inner Submersible External Inline 4 1 2 Diameter Barbed Outflow Fitting 1 2 inner Submersible External Inline 5 3 4 Diameter Barbed Outflow Fitting 1 2...
Страница 6: ...r 1 2 inner External Inline EcoPlus Mag Drive Utility Pump 700GPH Fixed Flow Rate Part number 748465 Pump Specifications Volts Hz Power GPH Height Max Current 120V 60 63W 700 12 ft 1 18A Accessory Spe...
Страница 7: ...flow Fitting 1 inner External Inline 7 1 Diameter Barbed Inflow Fitting 1 inner External Inline 8 3 4 Diameter Garden Hose Thread Connector 3 4 inner External Inline Operating Use Submersible Applicat...
Страница 8: ...ersible Application Image 1 Using pump with the sediment and pre filter with barbed outflow fitting Submersible Application Image 2 Using pump with the bottom draw inflow fitting and barbed outflow fi...
Страница 9: ...pond or reservoir keep in mind the pump must be lower than your pond or reservoir 2 Connect desired tubing size to the connection point on your pond or reservoir to the inflow barb fitting attached t...
Страница 10: ...age The water inflow or outflow pipe is clogged with foreign matters Remove foreign matters from pipes The pump runs normally at the beginning but the water flows out slowly or there is no water Impel...
Страница 11: ...11 Replacement Part Installation Instructions A B C...
Страница 12: ...12 Exclusively distributed by www sunlightsupply com www EcoPlusUSA com 20150120 Sunlight Supply Inc 2015...