eControls Comfort365 C365C32 Скачать руководство пользователя страница 1

Inside

Tu

Day

Upstairs

Downstairs

Airflow %

HEAT

Schedule

AUTO

FAN

MENU

MODE

Heat

Set To

SYSTEM

AM

365

Comfort

UP/DOWN

 Keys.

SYSTEM MODE

 Key

OFF, HEAT, COOL, AUTO or
EHeat

Displays the downstairs 
(Inside) or upstairs (Inside2)
temperature.

Displays the Thermostat Mode
HOLD, SCHEDULE or VACANT

Displays the time, day and schedule 
MORNING, DAYTIME, EVENING
or NIGHT

MENU 

Key Displays 

the User options.

MODE

 Key Selects

Thermostat Mode
HOLD, SCHEDULE or VACANT

Displays the upstairs airflow

Displays the heating or 
cooling temperature

FAN MODE

 Key

AUTO or ON

Description

System Modes

Airflow Limits

Nighttime Operation

Power

Warranty

Thermostat Modes

Programs per Day

Program Format

Temperature Override

Airflow Override

Airflow Control

Fan Modes

The C365 thermostat controls the heating and cooling system 
the same as most programmable thermostats. It also controls 
the airflow to the upstairs and downstairs using an upstairs and 
a downstairs modulating damper.  A temperature sensor located 
upstairs monitors the upstairs temperature and the temperature 
sensor in the C365 monitors the downstairs temperature.  

The C365 adjusts the upstairs and downstairs airflow during 
heating and cooling calls to maintain uniform upstairs and 
downstairs temperatures.  

Off, Heating only, Cooling only, Automatic Heating or Cooling.
And Emergency Heat (EHeat) when used with heat pumps.

Maximum upstairs and downstairs, heating and cooling airflow 
limits are set during installation.

Option used when bedrooms are located upstairs.  C365 uses 
the upstairs temperature sensor to control heating and cooling 
calls and directs more airflow upstairs.

Operates on 24VAC from the HVAC equipment to the Wiring 
Hub R and C terminals.

Hold, Schedule or Vacant mode.

Morning, Daytime, Evening and Night.

Weekdays and weekend– 5/2.

Up/down keys adjust the setpoint temperature.  Temperature 
setting is held for 4 hours when adjusted in Schedule mode.

Up/down keys adjust the upstairs/downstairs airflow.  Airflow 
setting is held for 4 hours when adjusted in Automatic mode.

Airflow control can be turned off using Option 18. Dampers 
fully open and airflow is no longer displayed on the thermostat.

Continuous or Automatic fan operation.

This thermostat is warranted to be free of defects due to 
workmanship or materials under normal use and service for a 
period of 5 years from date of installation and not longer than 
6 years from manufacturing date code.

Installer Manual

Model C365C32

365

Comfort

eControls, Inc. 26072 Merit Circle #110 / Laguna Hills, CA 92653

949-916-0945 Fax 949-458-8502 www.eControlsUSA.com

eControls

eControls

Ver 2.0 Jun 2017

Displays the downstairs airflow

NEXT 

Key 

Used to advance through
options

ENTER 

Key 

Used to save options and 
return to thermostat operation

Compatible Wiring Hub /HVAC Equipment

Compatible with wiring hub WH11 for gas/electric equipment 
with 1-stage heating and 1-stage cooling. Or, wiring hub WH32 
for gas/electric equipment, conventional or dual fuel heat 
pumps with 3-stage heating and 2-stage cooling. 

Upstairs Temperature Sensor

Modulating Dampers

One Model TS510W or two Model TS520W upstairs 
temperature sensors can be used and are wired to Wiring Hub. 
Or, use one or two Model TS5WL wireless temperature 
sensors. Wireless sensors require the ER1 radio module 
installed in the Wiring Hub.

Round or rectangular dampers using Model A80MJ plug and 
play, modulating actuators, plug into to the Wiring Hub.

Содержание Comfort365 C365C32

Страница 1: ...airflow upstairs Operates on 24VAC from the HVAC equipment to the Wiring Hub R and C terminals Hold Schedule or Vacant mode Morning Daytime Evening and Night Weekdays and weekend 5 2 Up down keys adjust the setpoint temperature Temperature setting is held for 4 hours when adjusted in Schedule mode Up down keys adjust the upstairs downstairs airflow Airflow setting is held for 4 hours when adjusted...

Страница 2: ...quired to define the upstairs or downstairs zones the second damper may be plugged into the connector marked OUT on the first damper LEDS on the damper actuator indicate when the damper is fully open green or fully closed red INSTALL UPSTAIRS DOWNSTAIRS DAMPERS Ensure that damper installation does not cause obstruction to the damper blade 2 5V GND SA WIRING HUB SB C365C32 Green LED Red LED Refer t...

Страница 3: ...ge persists turn the power off to the Wiring Hub When power is restored the Wiring Hub automatically detects which sensors are being used and clears the error messages When an nS error is detected the thermostat fully opens the Upstairs and Downstairs dampers and turns airflow control off as long as the nS error persists It still maintains control of heating and cooling calls When an Err 01 error ...

Страница 4: ... Calibrate Downstairs Sensor C A L 5 NA 05 Fan Operation FAn GA Up or EL Down GA Only displayed if GE selected 04 Heating Stages HtG 0 1 or 2 1 Only displayed if HP selected 14 15 16 17 18 19 21 20 22 23 Night Level LCD Backlight Airflow Control On or Off Up Stage Time Maximum Upstairs Airflow in Heating Maximum Downstairs Airflow in Heating Maximum Upstairs Airflow in Cooling Maximum Downstairs A...

Страница 5: ...ge the minimum off time minutes before restarting the compressor Touch NEXT or ENTER Option Option Touch the UP DOWN keys to change the minimum run time minutes before turning a system off Touch NEXT or ENTER Option Touch the UP DOWN keys to change the minimum off time minutes before restarting a gas furnace or electric strip heater Touch NEXT or ENTER 07 Compressor Minimum Off Time Factory Defaul...

Страница 6: ...ENTER Inside2 Option Touch the keys to set the time in minutes to update the upstairs and downstairs airflow Touch or UP DOWN NEXT ENTER Option This is the frequency in minutes that the damper position is updated 15 Calibrate Upstairs Temperature Sensor Factory Default None o Range 5 16 Airflow Update Time Factory Default 2 Minutes Range 1 to 20 Minutes Option Night Touch the key to turn the low l...

Страница 7: ...estore factory settings touch then touch the key NEXT ENTER BACK ENTER UP Option Maximum allowable temperature difference between the upstairs and downstairs temperatures When the temperature difference is equal to or greater than the allowed differential the airflow is adjusted When 2 or more Comfort365 sytems with wireless sensors are installed within 300 feet of one another the installations ha...

Страница 8: ... is too great and causes noise or annoyance Increase the airflow using the key until it is acceptable This is the maximum allowable downstairs airflow in heating Record the airflow value DOWN UP Maximum Allowable Downstairs Airflow in Heating 05 06 Testing Cooling Airflow Limits In Option 5 the system is Off Touch to go to Option 6 to activate cooling Verify the equipment is operating To determine...