EBV105 Z-Wave Plus Commands:
Z-Wave Network inclusion
Power button 3 or more time rapidly (within 1.5 seconds). It is
recommended to keep the EBV105 within 1M/3ft of the controller. (Set
controller to inclusion mode first)
Z-Wave Network exclusion
Power button 3 or more time rapidly (within 1.5 seconds). It is
recommended to keep the EBV105 within 1M/3ft of the controller. (Set
controller to inclusion mode first)
Device Reset
Press and hold the Power button for 10 seconds. The device will send
the reset notification to the list node in the group-1 and erases the
device memory. The led light flashes acknowledging successful reset.
Note: This should only be used in the event your networks primary
controller is missing or otherwise inoperable
Association capabilities
Setting the association: this device supports the “Switch_Binary_report”
to the node. Group 1-Lifeline setting supports up to 5 Nodes. (Group
2~5 is not supported)
Z-Wave Command Class
COMMAND_CLASS_BASIC
COMMAND_CLASS_VERSION
COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_MANUFACTURE_SPECIFIC
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_ASSOCIATION_GROUPINFO
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_SWITCH_ALL
If you have any questions or if you are experiencing any issues with the EBV105,
please contact EcoNet Controls Support via email at [email protected] or by phone at 905-332-8856.
For more details, please visit www.EcoNetControls.com.