EcoNet EBV105 Скачать руководство пользователя страница 1

 

  EBV105 Quick Start Guide 

Specifications 

 

 

The EBV105 Z-Wave Valve Controller requires 12V DC input at 1Amp (AC to DC Adapter included). The EBV105 can be paired with, and 
controlled using any Z-Wave compatible controller. The EBV105 also acts as signal repeater for the Z-Wave network, extending the Z-Wave 
transmission as part of the “mesh network”.  The EBV105 is designed to work with a pre-installed standard levered ball type water shut off 
valve.   If your water shut off valve is not a levered type, consult a plumber to have your shut off valve changed to a levered type.   
 

 

The EBV105 is designed to be installed onto an existing levered type ball valve as detailed below. Caution: If you do not have experience 
installing and configuring EBV105 type of devices, please consult a professional installer. 

 

 

 

 

Model: EBV105 (U.S.) 

 

Rated Voltage: 12V DC/1A 

 

Z-Wave Plus, 908MHz  

 

Wireless Range: 30M (line of sight) 

 

Valve Pressure:1.6Mpa 

 

Valve Size: ½” , ¾”, 1” (optional 1.25”) 

 

Close Time: 5 ~ 10 seconds 

 

Open Time:  5 ~ 10 seconds 

 

Torque: 30~60 kg.cm 

 

Accessories: 12V/1A power adaptor 

 

 

Pairing the EBV105 Z-Wave Automatic Valve with a Z-Wave Controller 

 

Including or Pairing the EBV105 to a Z-Wave Controller:  Place the Z-Wave controller in pairing (learning) mode. Press the SET/Power button 3 
or more times rapidly (within 0.5 seconds). Once the controller has acknowledged the inclusion, the EBV105 has been included in the Z-Wave 
network with the controller. Exit the pairing mode and you should see the EBV105 Automatic Valve under your list of devices.  Some devices 
(like the Vera controller) require that you reload or refresh the controller so it polls, identifies, and configures the new device. Once the 
configuration is complete, you can control the powered valve through your Z-Wave controller’s user interface.  The valve supports Open or On 
command and Closed or Off command through a standard Z-Wave controller.  The valve can also be open or closed with a single push of the 
power button on the unit, toggling from open to closed or closed to open.  The valve can also be open/closed manually by hand by pulling the 
clutch pin. 
 
Excluding or Un-Pairing the EBV105 to a Z-Wave Controller: Place your Z-Wave controller in exclusion (un-learning) mode. Once the 
controller is in exclusion mode, bring the EBV105 close to the Z-Wave controller (several feet) and press the Power button 3 or more time 
rapidly (within 0.5 seconds). Once the controller has acknowledged the exclusion, the EBV105 has been cleared of any previous 
inclusions/pairings. (It is recommended to keep the EBV105 within 1M/3ft of the controller when paring or un-pairing) 
 
There can be a number of reasons that the EBV105 does not work with your controller.  If the inclusion process does not work the first time, 
repeat the process but try “excluding” first and then complete the “inclusion” process.   
 

 

 