-9-
Figure 2 above: PV module installed with Screw fitting method*
2.3.2 Independent installation of Z-type clamp single module
The module clamps should not come into contact with the front glass and must not deform
the frame. Be sure to avoid shadowing effects from the module clamps.
The installation adopts Z-type clamp to ensure that each single module installation frame
can bear the mechanical load test includes wind load 2400Pa and snow load 5400Pa
independently.
The 2400Pa takes the inside mounting hole position as benchmark, and fix clamp
transverse bar
The 5400Pa takes the inside installation hole position as benchmark, and fix clamp
transverse bar.
8 9*14mm mounting holes
lght
The inner mounting holes
lght
The outside mounting holes
Содержание EN125M-72 Series