The battery must be charged through original external charger (AC-DC converter)
for maximum longevity and to preserve warranty.
NEVER PLUG THE BATTERY DIRECTLY TO THE GRID (AC).
●
Turn the circuit breaker disconnected while charging the battery connected to the
controller.
●
The charger connects to a conventional Schuko plug.
●
Estimated charge time is 5h from 0 to 80%. Over 80% charge gets slower for battery
longevity. Full charge may take about 8h.
●
To maintain battery in optimum conservation, it is not recommended to discharge
them under 30% if not necessary. We strongly recommend charging the battery before
every use.
●
The battery chemistry is NMC configured as 72V25Ah nominal (1.8kWh). 84V max.
●
NMC batteries has no memory effect, therefore you don’t need to full discharge it
to achieve a good performance.
●
The battery can be charged no matter the state of charge (SoC). Charging it
frequently will increase battery lifespan.
●
The temperature range for charging your battery is 0ºC to +35º. Do not charge the
battery under 0ºC or over 35ºC. Riding range is -15ºC to +40ºC.
16
BATTERY RECHARGE
Remember to keep the battery about 60% (76V) and cut off the circuit breaker when
long periods of inactivity, and keep checking battery voltage every month if possible.
GRID
Charge
plug
BATTERY
Discharge
plug
AC-DC
220VAC
84VDC