The following measurement procedures are available in the Pressure tests menu:
- Pressure Test
- Loading Test
- Tightness Test
- Usage property
In the menu Pressure Tests / Setup adjustments can be made for each measurement
procedure.
6.5.1 Pressure Test
The “Pressure Test” up to 100 hPa is deposited as a measurement routine in the ecom-EN3.
Proceed as follows:
1.
Close the conduit with a suitable adapter (test stopple, high-pressure
stopple or one-pipe counter cap).
2.
Connect the components as described before.
3. Scroll with cursor keys <Up/Down> to the menu “Pressure Test”. Activate with
<Enter>.
4. Create the pre-adjusted test pressure (max. 100 hPa) with the air pump.
5. Interrupt the connection to the air pump (switch-off the ball valve) and start “Pressure
Test” with <Enter>.
6. Wait for stabilization time (the measurement will start automatically).
7. Once the measurement time is over, the result is displayed and can be printed by
pressing <Print>.
8. If the menu “Pressure Test” is selected again, so the result can be called
up with <F4> (as long as the ecom-EN3 is on) or a new measurement
can be started with <F1>.
The following adjustments can be made in the menu Pressure Tests / Setup for the procedure
"Pressure Test":
Parameter
Meaning
Adjustment
Factory setting
Stabilization time
1 … 120 min
1 min
Measurement time
1 … 120 min
5 min