5. Control programs
After switching on of the instrument the following pre-programmed control pro-
grams are available:
Natural gas:
-Stress test acc. to TRGI 2018
-Tightness check acc. to TRGI 2018
-Usability check acc. to TRGI 2018
Liquid gas:
-Tightness check
-Pressure test
Drinking water:
-Drinking water plant (wet) acc. to DIN EN 806-4:
-Function test
-Pressure test
-Extended test
-Drinking water plant (dry) acc. to DIN EN 806-4:
-Tightness test
-Stress test
Heating:
-Heating installation acc. to DIN 18380
Sewage:
-Sewage installation acc. to DIN 1610
More measurements:
-Pressure check (arbitrary pressure)
In menu
„Adjustments“ / „Setup checks“
the parameters for the control pro-
grams can be adjusted:
5.1. Setup control programs
Scroll with the cursor keys
<up/down>
to the menu
„Adjustments“
. Activate the menu with
<Enter>
.
Scroll with the cursor keys
<up/down>
to the menu
point
„Setup checks“
and activate with
<Enter>
.
The following parameters can be adjusted:
Pressure check (arbitrary pressure):
-Stabilisation time (0 - 10 min, default: 0 min)
-Measurement time (0 - 6000 min, default: 0 min)
Respect the „Technical Rules for Gas installations“!
Natural gas
Liquid gas
Drinking water
Heating
Sewage
More measurement
Adjustments
Data storage
Fr 20.01.12 09:50:33
Setup checks
Set clock
Paper feeding
Print contrast
Displ. contrast
Key beep
Language: English
Pitot factor
Scan data logger
Printout
Select:
Adjustments
Содержание DP3