© 2016 Ecolink Intelligent Technology Inc.
PN SC-ZWAVE5-ECO R1.01
The device supports the Basic Command Class by mapping it to a Binary Switch Command Class. A 0xFF hex is
ON while a 0x00 is an OFF. The chime sound is very short and turns off by itself which might be a bit of an issue for
gateways that poll for the latest state with a get after a set.
ASSOCIATION
This device has a single association group which is group #1, and it can have 1 node in the group. It is intended for
receiving unsolicited reports as a part of the test button on the Siren+Chime.
TESTING THE Z-WAVE PLUS
T M
NETWORK
The Siren+Chime has a test button on the side of the device which will send a frame to the node as association
group 1. If the frame is successful in reaching node 1, the Siren+Chime will make a chime sound. If the reception is
poor the led will stay on while it retries and will make a low pitched single beep on failing to reach the destination
node.
Device Information
Device Classes
Generic Device Class
GENERIC_TYPE_SWITCH_BINARY
Specific Device Class
SPECIFIC_TYPE_SIREN
Command Classes
COMMAND_CLASS_ZWAVEPLUS_INFO
v2
COMMAND_CLASS_VERSION
v2
COMMAND_CLASS_MANUFACTURER_SPECIFIC
v2
COMMAND_CLASS_DEVICE_RESET_LOCALLY
v1
COMMAND_CLASS_POWERLEVEL
v1
COMMAND_CLASS_ASSOCIATION
v2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
v1
COMMAND_CLASS_FIRMWARE_UPDATE_MD
v2
COMMAND_CLASS_SWITCH_BINARY
v2
COMMAND_CLASS_MULTI_CHANNEL
V4
Manufacturer ID
MFG_ID_ECOLINK ( 0x014A )
Product Type
0x0A
Product ID
0x05