PN PIRZB1-ECO R1.00 Rev date 6/26/2017 

Problem

 

Solution

 

Attempt to pair the sensor is unsuccessful.

 

Reset the detector to default mode and then set to 
pairing  mode (see section 3.5).

 

The sensor and the Touchscreen (control panel)

 

do not communicate.

 

Perform the signal strength testing procedure 
described in the control panel installation manual. 
Make sure that the signal is sufficient. If necessary, 
replace the sensor

’s battery.

 

The sensor sends a Low Battery indication.

 

To ensure continuous proper operation, replace the 
battery within two weeks of the first Low Battery 
indication.

 

Panel does not arm because of an unrecognized 
sensor malfunction.

 

Consult with your installer or system provider before 
you disable  a zone. Disable the sensor  zone (see

 

the control  panel user manual). Note that disabling 
a sensor zone lowers the overall security level of 
your system.

 

4. TROUBLESHOOTING

If you encounter one of the  following problems with  the  PIRZB1-ECO, use the following solutions to 
resolve the problem:

 

PIRZB1-ECO

 

Wireless Digital  Pet Resistant  PIR Detector 

3

rd

 Party Certifications: FCC, IC, ETL, ZigBee HA, iControl

 

 Installation Instructions

1. INTRODUCTION

The PIRZB1-ECO pet resistant detector is a 
microprocessor-controlled wireless  digital  PIR 
detector  supported  by ZigBee Home Automation

 

1.2. The detector

’s  features are as follows:

 

A. Red LED

 

B. Green  LED

 

C. Tamper  Switch   

5. SPECIAL COMMENTS

Even the most  sophisticated  detectors  can sometimes  be defeated  or may fail to warn  due to: DC power failure

 

/ improper connection, malicious masking of the lens, tampering with the optical system, decreased sensitivity in 
ambient  temperatures  close to that of the human body and unexpected failure  of a component part. The above list 
includes the most common reasons for failure to detect intrusion, but is by no means comprehensive. It is therefore 
recommended  that the detector and the entire alarm system be checked weekly, to ensure proper performance. An 
alarm system should not be regarded as a substitute for insurance. Home and property owners or renters should be 
prudent  enough to continue insuring  their lives and property, even though they are protected by an alarm system.

 

6. COMPLIANCE WITH STANDARDS

FCC Statement:  This equipment has  been  tested  and  found  to comply  with  the  limits for  a Class B digital device,  pursuant to Part 15  of the 
FCC Rules. These limits are designed  to provide  reasonable protection against harmful  interference in a residential installation. This equipment 
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful 
interference  to radio communications.  However, there is no guarantee that interference  will not occur in a particular installation. If this 
equipment  does cause harmful  interference to radio or television reception, which can be determined by turning the equipment off and on, 
the user is encouraged to try to correct the interference by one of the following measures:

 

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician  for help.

Warning: Changes  or modifications not expressly  approved  by the Ecolink Intelligent Technology Inc. could void the user’s authority to operate 
the equipment. 

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the 
following two conditions: (1) this device may not cause interference, and (2) this device must accept any 
interference, including interference that may cause undesired operation of the device. 
Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est 
soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil 
doit accepter toute interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil. 
In accordance with FCC requirements of human exposure to radiofrequency fields, the radiating element shall be 
installed such that a minimum separation distance of 20 cm is maintained from the general population. 
Conformément aux exigences d'Industrie Canada en matière d'exposition humaine aux champs de 
radiofréquences, l'élément rayonnant doit être installé de telle sorte qu'une distance minimale de 20 cm soit 
maintenue par rapport à la population générale. 

FCC ID: XQC-PIRZB1ECO 
IC

 

ID: 9863B-PIRZB1ECO 

Installation shall be done in accordance with the Standard for Installation and Classification  of Burglar and Holdup Alarm Systems, UL 681.

 

2. SPECIFICATIONS

Detector Type:  

  Two - Dual element low-noise  pyroelectric sensor

 

Optical Data: 

 18 parabolic mirrors for long range

 

18 parabolic mirrors for close range

 

Max.  Coverage: 

 15 x 15 m, (49.2 x 49.2  ft) / 90°

 

Pet Immunity: 

  Selectable: (1.No immunity 2. Up to 40 lb 3. Up to 85 lb)

 

ELECTRICAL

 

Internal Batteries:     

 Two 3V Lithium  batteries,  type CR-123A.  For UL installations,  use Panasonic only

 

Nominal Battery Capacity: 

  1400  mAh per battery

 

Battery  Life  (with  LED on):      

  Typically over 5 years

 

Note: Inability to connect with wireless network, or wireless link quality resulting in intermittent  connection may 
significantly  reduce the expected battery life.

 

Battery Power  Test:  

 Performed immediately upon battery insertion and during each transmission to the panel

 

FUNCTIONAL

 

Alarm Period:     

 3 seconds

 

Visual Indications: 

  Red LED lights  for  about  3  seconds  upon transmission of alarm  & tamper  messages  and upon  motion

 

Detection in the  walk  test  mode  only (walk  test  mode  available  for  approx.  15  minutes).  Red LED flashes during 
the power-up  stabilization period, or after restoring (pressing) the tamper  switch  (power-up  stabilization period is 
approx.  1  minutes).  LED does not light  upon  transmissions of supervision messages  or alarm  detection  after 
termination of walk test mode.

 

Rearm  Timer:  

  Rearms the detector 2 minutes after the last alarm. Timer disabled in the walk test mode.

 

WIRELESS

 

Supported Network: 

  ZigBee H.A 1.2

 

Frequency:      

  2.405 

– 2.480 Ghz  as per IEEE 802.15.4

 

Tamper Alert:      

  Reported when a tamper  event occurs and in any subsequent message, until the tamper switch is restored

 

MOUNTING

 

Height:      

 1.8-2.4  m (6 - 8 ft). For pet rejection, the optimal height is 2.1  m (7 ft)

 

Installation Options:  

 Surface or corner

 

ENVIRONMENTAL

 

Operating  Temperatures      

  -

10˚ C to 55˚ C (14˚ F to 131˚ F) 

Storage  Temperatures      

  -

20˚ C to 65˚ C (-4˚ F to 149˚ F) 

COMPLIANCE WITH STANDARDS

 

USA  

CFR 47  part  15, 
ANSI/UL 639

 

PHYSICAL

 

Size (H x W x D)      

 83 x 61 x 42 mm (3.27 x 2.4  x 

1.66”)

 

Weight (with  battery) 

 90 g (3.17 oz)

 

Color      

  White

 

This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions:

(1) This device may not cause harmful interferene and (2) this device must accept any interference received, including interference that may 

cause undesired operation.