Ecolink NanoFIL Скачать руководство пользователя страница 9

 

Chapter 10: Customer Service and Warranty Clauses 

 NanoFil provide products within the scope of the provisions of the Three Guarantees service

 

1.

 

Consumers who have quality problems within 7 days from the date of purchase of the 
NanoFil Air Monitor have the option to return / exchange their products. 

2.

 

Consumers who have quality problems within 30 days from the date of purchase of the 
NanoFil Air Monitor have the option to replace new instrument. 

3.

 

Consumers enjoy a full year of warranty from the date of purchase of NanoFil Air Monitor 

 

Situations of non-warranty: 
    a) Purchase receipt and warranty card are the certificate for the Three Guarantees. Warranty 
service cannot be provided if there is any record modification or product information does not 
match with the real. 
    b) Disassemble or modify the product to cause malfunction or damage to the product; 
    c) M

an-caused damage

 

    d) Does not comply with the relevant provisions of the Three Guarantees; 
    e) Malfunctions caused by bad environment, such as excessive input voltage, moisture, 
corrosion, rust, etc .; 
If exceeding the warranty period, our company will only charge costs for repairing. 

 

Service hotline: (852) 3955 0207 
Working hours: Monday to Friday 9:00 am to 6:00 pm (Closed on holidays) 

 

 

Chapter 11. Recommended places

 

Suitable for a variety of indoor and outdoor places.

 

 

 

 

Chapter 12. Connection to Network 

1.

 

Press and hold the Power Button       on the monitor.  After powering on, press the MODE 
Switch button        to display the QR code screen.  Scan the QR code with your mobile phone 
to download the APP and register an account or login by Wechat.  After clicking the APP, 
select scan QR code and scan the QR code at the bottom of the instrument; 

Содержание NanoFIL

Страница 1: ...or that can simultaneously detect PM2 5 PM10 CO2 TVOC formaldehyde temperature and humidity data Users can register an account on NanoFIL cloud platform and associate it with different NanoFIL Air Monitors where their data detected will be displayed on PC terminal mobile App TV or display device for real time monitoring In addition the monitor can be used to automatically control air purification ...

Страница 2: ...hen the detection value exceeds the pre set parameter the device buzzer will automatically alarm Press the button once to turn off Press again to activate 5 WiFi Button Press the WiFi button to connect the device to the Internet Press again to turn off 6 Display Screen PM2 5 concentration value TVOC concentration value CO2 concentration value formaldehyde concentration value temperature and humidi...

Страница 3: ...Chaper2 Parameters PM2 5 CO2 TVOC Temperature Humidity Formaldehyde Air Inlet Air Outlet Air Outlet ...

Страница 4: ...2000ppm 50ppm 1ppm TVOC 0 000 9 999mg m 0 01mg m 0 01mg m Formaldehyde 0 000 4 0mg m 0 01 0 2mg m 5 0 01mg m Temperature Humidity 40 80 0 99 9 RH 1 1 0 1 RH Note If the instrument is placed in an environment beyond the measuring range for an extended period of time such as placing a cigarette at the instrument air inlet for a long time it may result in measurement error Environmental conditions Wo...

Страница 5: ... concentration data CO2 sensor collects data by NDIR infrared measurement principle Formaldehyde is detected by the principle of electrochemical TVOC is detected by the principles including semiconductor measurement Chapter 4 Product Features 1 The latest technology the current PM2 5 laser scattering precision detection technology sensitive response accurate data measurement 2 Real time detection ...

Страница 6: ...measurement at different points of a room and calculate an average value of the measurement results then it will be the average pollution value of the room Chapter 6 Calibration Calibration instructions 1 First place the instrument in a good place such as outdoor balcony window turn on the instrument for more than 10 minutes TVOC will be automatically calibrated 2 Press MODE switch button to selec...

Страница 7: ...ntration Comparison Table TVOC Concentration Comparison Table CO2 Concentration ppm Air Quality TVOC Concentration mg m Air Quality 450 700 Fresh 0 0 0 6 Good 700 1000 Better 0 6 1 0 Mild pollution 1000 1500 Little turbid 1 0 1 6 Moderate pollution 1500 2000 Turbid Above 1 6 Severe pollution Formaldehyde Concentration Comparison Table Formaldehyde Concentration mg m Air Quality 0 00 0 03 Excellent...

Страница 8: ...sors will decrease Therefore please do not leave the monitor work in prolonged low temperature longer than 30 minutes 4 Ensure the air flow is stable Gas molecules in space have been following random Brownian motion gas distribution is susceptible to air flow interference As far as possible to make the air flow stable before measurement 5 Not used for a long time When monitor has not been used for...

Страница 9: ...ormation does not match with the real b Disassemble or modify the product to cause malfunction or damage to the product c Man caused damage d Does not comply with the relevant provisions of the Three Guarantees e Malfunctions caused by bad environment such as excessive input voltage moisture corrosion rust etc If exceeding the warranty period our company will only charge costs for repairing Servic...

Страница 10: ...bile phone is connected to the WiFi router or the WiFi password is correct If there is no problem press the WiFi button and turn it off for 3 seconds Then turn it on and repeat Step 2 5 According to users requirements it can be provided in digital TV and advertisement machines Users simply log in the APP on the interface the data of each detecting points can be monitored in real time Adding device...

Страница 11: ...nt to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occu...

Отзывы: