Wake-Up Notification 

The sensor will wake up every so often and when the case is closed to send a Wake-Up Notification to allow the life line master node controller that the sensor is 
now available for any queued messages that the controller may have for the sensor. The time between Wake-Up Notifications can be configured with the Wake-
Up Notification command class to be between 1 hour and 1 week with interval steps of 200 seconds.  

Configuration 

The sensor has two configuration parameters. Parameter 1 configures the sensor to send or not send Basic Set commands of 0x00 to nodes in Association group 
2 turning the devices off when the sensor is in a restored state i.e. the door is closed. By default the sensor does NOT send Basic Set commands of 0x00. 
Parameter 2 configures the sensor to either to send or not to send Sensor Binary Report commands to Association Group 1 when the sensor is faulted and 
restored. If the controller is fully compatible with the Notification Command Class thereby making the Sensor Binary Reports redundant, the controller can 
disable the Sensor Binary Report Commands completely. The following table shows the values to enable and disable the two configuration parameters. 

 

Configuration Set Values 

Effect 

Parameter Number: 1 
Size: 1 
Configuration Value: 0x00 

(Default) Sensor does NOT send Basic Sets to Node 
IDs in Association Group 2 when the sensor is 
restored ( i.e. Door/Window Closed ). 

Parameter Number: 1 
Size: 1 
Configuration Value: 0xFF 

Sensor sends Basic Sets of 0x00 to nodes in 
Association Group2 when sensor is restored. 

Parameter Number: 2 
Size: 1 
Configuration Value: 0x00 

(Default) Sensor sends Sensor Binary Reports when 
sensor is faulted and restored for backwards 
compatibility in addition to Notification Reports. 

Parameter Number: 2 
Size: 1 
Configuration Value: 0xFF 

Sensor will send only Notification Reports and NOT 
Sensor Binary Reports when the sensor is faulted 
and restored. 

  

 

 

 

ENGLISH  

Содержание H114101

Страница 1: ...fic controller for details on initiating the controller s inclusion mode STEP ONE Start by placing the controller into inclusion mode STEP TWO Activate inclusion mode for the sensor by removing the plastic pull tab from the back of the sensor When the inclusion process is complete the LED on the sensor will be solid blue then go out STEP THREE Test the sensor Place the magnet next to the sensor to...

Страница 2: ...ontains the following 1 Door Window Sensor 1 Sensor Mounting Bracket 2 Screws for Sensor Mounting Bracket 1 Adhesive tape for Sensor Mounting Bracket 1 Sensor Magnet 2 Screws for Sensor Magnet 1 Adhesive tape for Sensor Magnet STEP ONE Identify Location for Sensor and Magnet Determine where on the door or window you are able to mount the sensor and magnet Note that the sensor has a line and arrow ...

Страница 3: ...Right hand door mounting arrow pointing down magnet on right side STEP TWO Mount the sensor and magnet to a clean dry surface with the adheasive tape and or the screws provided Fixed jamb Door Adhesive Tape Mounting Bracket Screws optional Magnet Fixed jamb Door Adhesive Tape Mounting Bracket Screws optional Sensor ...

Страница 4: ...to engage the sensor The required orientation of the sensor determines the bracket orientation The sensor slides onto the bracket until the tab engages Please be advised that adhesive tape may damage the surfaces to which it is attached BROWN PLASTIC HOUSINGS OPTIONAL Included with every Ecolink Door Window Sensor is a second set of plastics in BROWN If your door or window is darker in color you m...

Страница 5: ...TIFICATION_SENSOR and the supported command classes are COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_VERSION COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_WAKE_UP COMMAND_CLASS_SENSOR_BINARY COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_BASIC Manufacturer Specific...

Страница 6: ...nd sensor binary reports Group 2 is intended for devices that are to be controlled i e turned on or off on only by default with a Basic Set On inclusion the controller should put its node ID in group 1 but not group 2 Network Wide Inclusion This sensor also supports Network Wide Inclusion such that the Sensor can be included into the Z Wave network over the mesh network and not directly near the m...

Страница 7: ...ensor Binary Report of 0x00 Sensor Type 0xFF 1 Yes via Configuration Command Class Parameter Number 2 Size 1 A Configuration Value 0xFF On 0x00 Off Basic Set of 0x00 Off By factory default this feature is disabled and must be enabled via Configuration Command Class 2 Yes via Configuration Command Class Parameter Number 1 Size 1 A Configuration Value 0xFF On 0x00 Off Parameter Number 2 Sensor Case ...

Страница 8: ...ary Report commands to Association Group 1 when the sensor is faulted and restored If the controller is fully compatible with the Notification Command Class thereby making the Sensor Binary Reports redundant the controller can disable the Sensor Binary Report Commands completely The following table shows the values to enable and disable the two configuration parameters Configuration Set Values Eff...

Страница 9: ...a fault is the result from accident misuse abuse neglect mishandling misapplication faulty installation improper maintenance alteration modifications fire water lightning natural disasters wrong use or carelessness To obtain warranty service during the warranty period please notice that we need your original purchase receipt so that we may establish your eligibility for service If you have bought ...

Страница 10: ... address xxxxxxxxxxxxxxxx RECYCLING WEEE DIRECTIVE This product bears the selective sorting symbol for waste electrical and electronic equipment WEEE This means that this product must be handled pursuant to European directive 2012 19 EU in order to be recycled or dismantled to minimize its impact on the environment User has the choice to give this product to a competent recycling organization or t...

Отзывы: