13
110007941
Software Manual
C14 Warning
leakage start
1. Booster start condition changed to flow, due to
leakage in pipe
1. Check for leakage in pipe system.
2. Press “off” button
3. If error reoccurs, contact your local
service technician.
C20 Low Sensor
Signal P-Pump-
top
1. Pressure signal from pumptop sensor, out of range 1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C21 Low Sensor
Signal T-Pump-
top
1. Temparature signal from pumptop, sensor, out of
range
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C22 Low Sensor
Signal P-Inlet
1. Pressure signal form inlet sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C23 Low Sensor
Signal T-Inlet
1. Temperature signal from inlet sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C24 Low Sensor
Signal block
1. Signal from block sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C25 Low Sensor
Signal flow
1. Signal from flow sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C30 High Sensor
Signal P-Puump-
top
1. Pressure signal from pumptop sensor, out of range 1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C31 High Sensor
Signal T-Pump-
top
1. Temperature signal from pumptop sensor, out of
range
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C32 High Sensor
Signal P-Inlet
1. Pressure signal from inlet sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C33 High Sensor
Signal T-Inlet
1. Temperature signal from inlet sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C34 High Sensor
Signal block
1. Signal from block sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C35 High Sensor
Signal flow
1. Signal from flow sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C40 Sensor Load
Pumptop Sensor
1. Supply voltage for pumptop sensor too low.
2. Pumptop sensor using too much current
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C41 Sensor Load
Inlet sensor
1. Supply voltage for inlet sensor too low
2. Inlet sensor using too much current
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C42 Sensor Load
Block sensor
1. Supply voltage for block sensor too low
2. Block sensor using too much current
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C43 Sensor Load
Flow sensor
1. Supply voltage for flow sensor too low
2. Flow sensor using too much current
1. Press “off” button
2. If error reoccurs, contact your local
service technician.
C45 Inverter
Module temp.
1. Water consumption too high
2. Ambient temperature too high"
1. Lower the load for inverter
2. Lower the ambient temperature"
C46 Inverter
Board temp."
1. Water consumption too high
2. Ambient temperature too high
3. Load at Board high"
1. Lower the load for inverter
2. Lower the ambient temperature
3. lower the load at board"