Ecolab BF4-P Скачать руководство пользователя страница 1

Software Manual

Control Panel for Hybrid Units

Models: 
MU421-P
MU422-P
BW4-P
BW7-P
BF4-P
BF8-P

 

 

        Software Manual

EN

Содержание BF4-P

Страница 1: ...Software Manual Control Panel for Hybrid Units Models MU421 P MU422 P BW4 P BW7 P BF4 P BF8 P Software Manual EN...

Страница 2: ......

Страница 3: ...the Info menu 10 5 2 Content of the Errors menu CAUSE REMEDY 11 5 2 1 Error List 11 5 3 Content of the Setup sub menu Settings 13 5 4 Content of Setup menu 14 5 4 1 Submenu Language Units 16 5 4 2 Su...

Страница 4: ...unit is operated via the control panel see below illustration 1 OFF Button 1 switches OFF the unit 2 ON STANDBY Button 2 switches ON the unit 3 ERROR Error light indicator 3 4 NAVIGATION BUTTONS The f...

Страница 5: ...ive navigation buttons on the control board The arrows illustrate that it is possible to scroll up and down between the menus Scrolling to the right makes it possible to enter a value Set the value sc...

Страница 6: ...s not set date and time will count from the pre set default date and time 2006 01 01 12 00 Date time EP Set date and time using navigation buttons Set date time 2006 01 01 12 00 Confirm by pressing OK...

Страница 7: ...de Scroll down to return to STANDARD pressure Screen display STANDARD pressure Scroll up to choose HP and scroll down to choose LP Screen display for Low Pressure unit in Run Mode Scroll up to return...

Страница 8: ...ROR WARNING In case of an error ERROR will appear on the display screen Press the OFF button to switch of unit If the error remains when the unit is switched ON again please Press right arrow to see c...

Страница 9: ...Main and Submenus The control panel contains the below main menu screen displays Scroll between the menus using the navigation buttons Each main menu contains submenus which will be described subseque...

Страница 10: ...Start level EC Auto off delay EZ Accelleration time EU Date Time EP Service text EJ Inverter power EO Backlight intensity EI Display contrast EV User password EL Standard settings EK 3 Languages unit...

Страница 11: ...rs AB TRIP Power 0kWh ABA Hours 0h Displays accumulated consumption of power and operation hours To reset the trip counter go to the setup menu Service center AD SERVICE ADA Enter TEXT HERE Displays n...

Страница 12: ...e that all air channels are open and not blocked by impurities 2 Lower ambient temperature C5 High Supply Temp 1 Water inlet temperature is above 70 1 Lower the water temp max 70 C 2 Contact your loca...

Страница 13: ...High Sensor Signal P Inlet 1 Pressure signal from inlet sensor out of range 1 Press off button 2 If error reoccurs contact your local service technician C33 High Sensor Signal T Inlet 1 Temperature s...

Страница 14: ...the Setup sub menu Settings The Setup Main menu contains the below submenus which will be described subsequently Setup C 0000 Password CA Settings S E Languages L F units Supply H tank Communication I...

Страница 15: ...ed menus Set Post run time level 0 5 bar Dry run EE level 0 5 bar Dry run EEA OK Set dry run level pressure 25 bar Standard ER pressure 25 bar Standard ERA OK Set standard pressure pressure 25 bar Hig...

Страница 16: ...A Enter TEXT HERE OK Enter name and tel no of Your local service technician power 11000W Inverter EO power 11000W Inverter EOA OK Set rated power of frequency inverter intensity 75 Backlight EI intens...

Страница 17: ...FF Tank HA Control OFF Tank HAA OK LLA Detect Delay 3 sec HB LLA Detect Delay 3 sec HBA OK 5 4 3 Submenu Communication Communication I PC For the use of authorized Your local service technician only F...

Страница 18: ...ive when it is stopped Standby off active if booster is running or in standby Output 2 options None No function Delay start Gives a signal at this port before starting the pump The length of the delay...

Страница 19: ...For the use of authorised Your local service technician only 5 4 6 Submenu Reset Reset R D Reset trip counters DA Reset DAA OK 5 5 Content of Readings Readings R Pump state 82Hz RA 24bar Outlet pres R...

Страница 20: ...Start PC App 5 Disconnect display from usb cable and connect it again Power cycle 6 Make sure the Green ON led and the red OFF led at the display is both on display is blank 7 Startup PC program FWU2...

Страница 21: ...pgrade is complete the FWU tool should be looking like this Button turns Green and text changes to DONE NEW 17 Now the display is upgraded 18 To verify software version in display in the menu go to In...

Страница 22: ...R and red OFF and the display is blank 6 Connect Irda module Item No 110001558 to PC USB port 7 Place Irda module on display module like this 8 Startup PC program FWU200 exe can be downloaded from Nil...

Страница 23: ...pgrade is complete the FWU tool should be looking like this Button turns Green and text changes to DONE NEW 18 Now the display is upgraded 19 To verify software version in display in the menu go to In...

Страница 24: ...ervice switch AWARE OF HIGH VOLTAGE IN INVERTER 7 Start up Firmware upgrade program Can be downloaded from Nilfisk FOOD web 8 Click browse to select upgrade file hex Can be downloaded from Nilfisk FOO...

Страница 25: ...ice switch wait for unit to discharge approximately 5 min 14 Disconnect the usb cable from inverter 15 Connect the display to modbus connector again 16 Mount the lit of the inverterbox 17 Turn unit ba...

Страница 26: ...No 110007941D 05 2022 Printed in Denmark...