417102214_EDPL_V60.docx
96
Rev. 1.12.11
10.4.11.2 Display view in the operating level with an active pulse memory
Display view in operation
Pos.
Description
1
Pulse memory enabled (flashing icon = stored pulses are
currently being processed)
Fig. 10.33
10.4.12 Configuration / Oval gear meter (
V60
PLUS
& OGM or OGM
PLUS
only)
The oval gear meter function makes it possible to record a “real” value in the Operating
data/Litres menu option (see chapter
Operating data / Litres
”).
Furthermore, this menu option must be enabled to use the metering controller function
(see chapter
Configuration / Metering controller (
V60
PLUS
& OGM or OGM
PLUS
only)
”).
NOTE
The oval gear meter menu option can only be enabled if the pump is upgraded to the
V60
PLUS
by a dongle board and an oval gear meter (see Accessories) has been connected.
In order to activate the dongle board in connection with the oval wheel meter, the mains
voltage must be isolated and restored. (Unplug power plug or switch the pump off and
back on again!) The oval gear meter function is automatically activated when an OGM
PLUS
is connected.
10.4.12.1 Selection
Fig. 10.34
-
The oval gear meter is inactive.
(Default setting)
The oval gear meter is active
10.4.13 Configuration / Metering controller (
V60
PLUS
& OGM or OGM
PLUS
only)
Fig. 10.35
If an OGM Plus is connected, when the metering controller function is activated, the metering
quantity measured by the OGM is compared with a pre-defined target metering quantity. If
there is a discrepancy between the values, the metering frequency of the pump is
automatically increased or decreased.
Since metering frequency can only be adjusted within the performance limitations of the
pump, setting the metering rates higher than 80 or 90% of the maximum possible metering
frequency is not recommended. This will ensure that the metering controller retains sufficient
reserves to react to negative control deviations.
NOTE
The metering controller function can only be enabled if the pump is upgraded to the
V60
PLUS
by a dongle board and an oval gear meter OGM
PLUS
(see Accessories) has been
connected.
In order to activate the dongle board in connection with the oval wheel meter, the pump
must be switched off and then on again.
Содержание 417102214
Страница 60: ...417102214_EDPL_V60 docx 60 Rev 1 12 11 14 7 3 F rderleistung Typ 06700 0 4 MPa 4 bar Abb 14 5...
Страница 61: ...417102214_EDPL_V60 docx 61 Rev 1 12 11 15 Konformit tserkl rung...
Страница 120: ...417102214_EDPL_V60 docx 120 Rev 1 12 11 14 7 3 Pump capacity on type 06700 0 4 MPa 4 bar Fig 14 5...
Страница 121: ...417102214_EDPL_V60 docx 121 Rev 1 12 11 15 Declaration of conformity...
Страница 180: ...417102214_EDPL_V60 docx 180 Rev 1 12 11 14 7 3 D bit type 06700 0 4 MPa 4 bar Fig 14 5...
Страница 181: ...417102214_EDPL_V60 docx 181 Rev 1 12 11 15 D claration de conformit...