417102214_EDPL_V60.docx
105
Rev. 1.12.11
11
Maintenance
CAUTION
Always rinse the metering head to remove dangerous media and depressurise the
pressure circuit before repair and servicing work. Wear protective clothing (safety goggles,
safety gloves and apron).
Repairs on electrical equipment may only be carried out by trained electricians
(Employers' Liability Association safety rules VB G 4 and ZH 1/11).
CAUTION
Live parts may be exposed when opening covers or removing parts, apart from covers that
can be opened or parts that can be removed without using tools). Connection points may
also be live.
Before any adjustment, maintenance work, repair work or exchange of parts, the device
must be disconnected from all sources of power if opening of the device is necessary.
NOTE
The normal maintenance interval is every six months, but shorter intervals may be
required if parts are subjected to heavy stresses (e.g. continuous operation)
.
The following inspections are recommended:
suction pipes and pressure pipes for leak-free connections;
suction valve and pressure valve for dirt and tightness;
Setup
”, Fig. 5.1) on pump head (for diaphragm bursts);
correct metering;
metering head screws (stable seat, 12 Nm);
, “
Exchanging the pump head and the diaphragms
” Fig. 11.5, pos.
1
),
oil level on the oil-level gauge glass (minimum fill quantity, see Fig. 11.6).
NOTE
The service life of the diaphragm depends on the following:
•
Back-pressure, operating temperature and metering medium.
We recommend that you check the diaphragm more frequently in extreme operating
conditions and if metering abrasive substances.
11.1
Replacement of suction/pressure valves
Loosen value in an anticlockwise direction using a spanner
(1¼" valve SW 41; 2" valve SW 56) and unscrew it.
Exchange o-rings.
Screw the valve into the metering head; heed the direction arrow! (Points up!)
NOTE
Fig. 11.1
The direction of flow is marked by an impressed arrow on
the suction/pressure valves.
When installing the valves, ensure that the flow direction
is correct.
11.1.1 Installation drawing
Fig. 11.2
Description
SUCTION/PRESSURE VALVE - 2200 type
1
O-ring, Ø 28 x 3.5
2
Suction/pressure valve
SUCTION/PRESSURE VALVE - 04800 type and 06700 type
1
O-ring, Ø 40.87 x 3.53
2
Suction/pressure valve
Содержание 417102214
Страница 60: ...417102214_EDPL_V60 docx 60 Rev 1 12 11 14 7 3 F rderleistung Typ 06700 0 4 MPa 4 bar Abb 14 5...
Страница 61: ...417102214_EDPL_V60 docx 61 Rev 1 12 11 15 Konformit tserkl rung...
Страница 120: ...417102214_EDPL_V60 docx 120 Rev 1 12 11 14 7 3 Pump capacity on type 06700 0 4 MPa 4 bar Fig 14 5...
Страница 121: ...417102214_EDPL_V60 docx 121 Rev 1 12 11 15 Declaration of conformity...
Страница 180: ...417102214_EDPL_V60 docx 180 Rev 1 12 11 14 7 3 D bit type 06700 0 4 MPa 4 bar Fig 14 5...
Страница 181: ...417102214_EDPL_V60 docx 181 Rev 1 12 11 15 D claration de conformit...