Static Pressure Controlled Bypass    (MODULATING)

 Air Probe (Pitot Tube)

DO NOT allow 

supply air 

pressure to blow 

directly into the 

pitot tube

PITOT

TUBE

To test if bypass is sized and 

configured properly, make a call ONLY 

from the smallest zone for cooling with 

the fan at the HIGHEST speed and the 

BYPASS Damper should fully or almost 

fully open within 1 to 2 minutes

Just as soon as the motor starts to 

run open, turn the knob back 

clockwise just enough that the 

damper motor stays closed.

(ECOJAY damper RED light will be 

solid)

ecojay

P

O

P

C

C

O

M

ecojay

P

O

P

C

C

O

M

4

AIRFLOW

Locate the air probe (pitot 

tube) at least

2 FEET

downstream from the air 

source, preferably as close 

to the center of the 

airstream as possible

2 -2.5

10"

3 -3.5

12"

4 -4.5

14"

5

14 -16"

Unit Size 

Round Damper

(Tons)

Size (Inches)**

BYPASS DAMPER “RULE OF THUMB”

 

Below chart assumes 400 CFM per Ton 

**USE next size UP round bypass damper for any 

system with a single zone less than 200 CFM.

BYPASS DAMPER (Pressure Relief)

 

A bypass system 

consists of a short duct connecting the supply plenum to the return 

air plenum.  

A “bypass” damper is installed in this duct that opens

/

closes automatically to maintain constant pressure inside the duct 

when zones open and close.   When the correct size bypass damper 

is installed and adjusted correctly, it will be fully CLOSED when all 

zones are calling (no air bypassing) and will OPEN proportionately 

as more zone dampers close.

BYPASS DAMPER SIZING:

Select a round damper size with a Max CFM greater than the CFM-

Needed to bypass.  Use the formula below to calculate CFM needed 
to bypass and the ROUND DAMPER CFM CHART to check Max CFM.

T

YPICALLY

 400 

CFM

  

PER

  

TON

U

SE

 

“N

ORMAL

 

CFM” 

FROM

 

THE

 CFM CHART

(P

AGE

: 8)

U

SE

 

A

 BYPASS 

D

AMPER

 

THAT

 

HAS

 LARGER 

“M

AX

 

CFM”

800   = 2

1200 = 3

1600 = 4

2000 = 5

Bypass SIZE

E

QUIPMENT

 A

IRFLOW

C

APACITY

 

IN

 CFM (

HIGH

 

SPEED

)

CFM 

OF

S

MALLEST

 ZONE

CFM-N

EEDED

TO

 BYPASS

EXAMPLE: 4-T

ON

 

EQUIPMENT

 

WITH

  10" 

SMALLEST

 

ZONE

:

                  1600 CFM

(

EQUIPMENT

)

 

              

   400 CFM 

(

SMALLEST

 

ZONE

 

 N

ORMAL

 CFM 

ON

 P

AGE

: 8) 

      = 1200 CFM N

EEDED

               

     

SO, 

FROM

 

THE

 R

OUND

 D

AMPER

 MAX CFM 

ON

 P

AGE

: 8, 

A

 14" 

ROUND

 

DAMPER

 

SHOULD

 

BE

 

USED

 

FOR

 BYASS.

Initial Weight-Arm Positions

 

depend on 

AIRFLOW            

and 

ORIENTATION

 of the bypass damper.  Below are the four (4)  

initial weight arm positions.  Select AIRFLOW & ORIENTATION for specific application.

NOTE: Extra weight may be required for 

upflow applications. (Order ABDW)

Up-Flow

o’clock Position

Left to Right

o’clock Position

Right to Left

o’clock Position

Down-Flow

o’clock Position

11

Содержание SmartZone 2X

Страница 1: ...T SPARE FUSE INCLUDED FULL STATUS DIGITAL DISPLAY STATUS LEDs SHOW HEAT or COOL CALLS No Voltmeter Required EXCLUSIVE ECO FOR ENHANCED CONTROL QUICK SCREWLESS TERMINALS SmartZone 4X ZS4X 2 0 SCAN WITH...

Страница 2: ...RANSFORMER NOT INCLUDED MUST BE SIZED AND FUSED BASED ON THE SMARTZONE CONTROLLER TOTAL DAMPERS AND THERMOSTATS POWER 14 VA 12VA 3 VA 10 VA 2 VA ECOJAY Device SmartZone 4X SmartZone 2X Power Open Clos...

Страница 3: ...AC HOT RED C Common NONE Y Compressor YELLOW G Fan GREEN W Heat OR Emergency Heat RED O B Reversing Valve ORANGE EC Economy Input GREEN Zone ONE only SmartLINK COMM SPECIFICATIONS 3 DISPLAY OPERATION...

Страница 4: ...PMENT W1 EH AUX HEAT W1 Auxiliary Heat energizes while Y1 Y2 de energize at a supply temp cooler than 90 F after 6 minutes run time of Y1 Y2 only W1 Auxiliary Heat de energizes at a supply temp of 100...

Страница 5: ...1 Y2 will de energize at a supply temp cooler than 90 F after 6 minutes run time of Y1 Y2 W1 Auxiliary Heat remains energized until all heat calls are satisfied or the supply temp gets warmer than GAS...

Страница 6: ...ic Equipment Heat Pump Equipment Reversing valve energized in COOLING Reversing valve energized in HEATING Operates Aux Heat WITH compressor HP Only Operates Aux Heat WITHOUT compressor 2nd Stage Acti...

Страница 7: ...AS or ELECTRIC HEAT COIL RETURN AIR AIR FLOW INSTALL SAS AFTER the COIL but BEFORE the BLOWER HEAT PUMP Standard Electric Aux SUPPLY PLENUM ELECTRIC Auxiliary HEAT COIL RETURN AIR AIR FLOW ECOJAY Smar...

Страница 8: ...re foot SPRING DAMPERS use a motor to power the damper blade in ONE direction and a spring to move the blade in the opposite direction When power is applied to the damper the motor moves the blade Whe...

Страница 9: ...TEMP LO TEMP SUPPLY PURGE DELAY ECO FRESH AIR Setup Configuration BUILTINTOSMARTZONE 4XWILLAUTOMATICALLY ENERGIZEFANANDOPENFRESHAIRDAMPER ZONE4 DURING FRESHAIRRUNTIME FRESH AIR CONTROL FRESHAIRCANBEC...

Страница 10: ...ter clockwise until the bypass damper motor starts to run open ECOJAY damper GREEN light will flash ecojay PO PC COM 1 2 3 Connect the flexible tubing to the HIGH PRESSURE INLET as shown Pressure inle...

Страница 11: ...to maintain constant pressure inside the duct when zones open and close When the correct size bypass damper is installed and adjusted correctly it will be fully CLOSED when all zones are calling no ai...

Страница 12: ...SMARTZONE B DUAL FUEL ELECTRIC VLV O NORMAL FAN GAS LOCKOUT 2nd STAGE SMART LINK ZONES 5 8 ZONES 1 4 SMART LINK 1 GND 2 DIP SWITCH 6 should be set to ZONES 5 8 on secondary SmartZone 4X ONLY ZONE 5 to...

Отзывы: