Ecojay SmartZone 2X Скачать руководство пользователя страница 1

ecojay

eco

jay

ZONING GUIDE

Installation, 

Specification & 

Operation

P

O

W
E

R

D

A

M

P

E

R

 1

24V

24C

Z1-PO

Z1-PC

ADJUST SETTINGS

RC

RH

COM

W2

O/B

Y1

Y2

G

E

Q

U

IP

M

E

N

T

REMOVE TO SEPARATE 
RC & RH TERMINALS

COM

Z

O

N

E

 1

 S

T

A

T

R

EC

Y

G

O/B

W

Z

O

N

E

 2

 S

T

A

T

R

C

Y

G

O/B

W

D

A

M

P

E

R

 2

Z2-PO

Z2-PC

COM

C

STAT

 TYPE

S

M

A

R

T

 L

IN

K

1

GND

2

S

A

 S

E

N

S

O

R

SA1

SA2

W1

EH

I88

HI TEMP
LO TEMP

SUPPLY

PURGE

DELAY ECO

RESET

HEAT PUMP
B
DUAL FUEL

ELECTRIC

GAS/ELECT

RVS. VLV. O

NORMAL

FAN GAS

LOCKOUT

2

nd

 STAGE

SMART LINK

ZONES (1 – 4)

ZONES (5 – 8)

ecojay

S

MART

Z

ONE

Z

O

N

E

 3

 S

T

A

T

R

C

Y

G

O/B

W

Z

O

N

E

 4

 S

T

A

T

 o

F

A

R

C

Y

G

O/B

W

D

A

M

P

E

R

 3

Z3-PO

Z3-PC

COM

D

A

M

P

E

R

 4

Z4-PO

Z4-PC

COM

FRESH AIR

3

0

0

 m

A

SmartZone-4X 

(ZS4X-2.0) 4 ZONE

ecojay.com 

 

888-523-ECOJ

(3265)

HEAT PUMP

 OR 

GAS/ELECTRIC 

THERMOSTAT

SPARE FUSE 

INCLUDED

FULL STATUS

DIGITAL 

DISPLAY

STATUS LEDs 

SHOW HEAT or 

COOL  CALLS

(No Voltmeter 

Required) 

EXCLUSIVE “ECO” 

FOR ENHANCED 

CONTROL

QUICK

SCREWLESS

TERMINALS

SmartZone

4X

ZS4X 

2.0

SCAN WITH 

SMARTPHONE FOR 

MORE INFO

FRESH AIR 

CONTROL

 (4X ONLY)

STATUS LEDs SHOW

DAMPER POSITION 

RED = CLOSED

GREEN = OPEN

USE ANY DAMPER

2-WIRE or 3-WIRE

(Power Open/Close, 

Spring Open, 

or Spring Close)

SIMPLE SETUP 

AND

CONFIGURATION

DUAL FUEL

CAPABILITY

COMPATIBLE EQUIPMENT:

GAS/FOSSIL FUEL/ELECTRIC

or

HEAT PUMP (Inc. DUAL FUEL)

up to

2-STAGE Cooling

3-STAGE Heating

SUPPLY AIR 

TEMP SENSOR 

INCLUDED

EXPANDABLE

TO 8 ZONES

p. 3

p. 6

p.6

p. 9

p. 7

p. 7

p. 4,5,7

p. 5

p. 12

p. 7

p. 4,7

2.0

ROUND AND 

RECTANGULAR

DAMPERS

Available in over 60 

different sizes and 

configurations!

DAMPER SIZING

 & DUCT DESIGN

p. 8,9

PLEASE REVIEW ENTIRE DOCUMENT BEFORE BEGINNING INSTALLATION

SmartZone-2X 

(ZS2X-2.0) 2 ZONE

BYPASS 

(PRESSURE 

RELIEF)

p. 10,11

Supply 

Damper

Bypass 

Damper

Содержание SmartZone 2X

Страница 1: ...T SPARE FUSE INCLUDED FULL STATUS DIGITAL DISPLAY STATUS LEDs SHOW HEAT or COOL CALLS No Voltmeter Required EXCLUSIVE ECO FOR ENHANCED CONTROL QUICK SCREWLESS TERMINALS SmartZone 4X ZS4X 2 0 SCAN WITH...

Страница 2: ...RANSFORMER NOT INCLUDED MUST BE SIZED AND FUSED BASED ON THE SMARTZONE CONTROLLER TOTAL DAMPERS AND THERMOSTATS POWER 14 VA 12VA 3 VA 10 VA 2 VA ECOJAY Device SmartZone 4X SmartZone 2X Power Open Clos...

Страница 3: ...AC HOT RED C Common NONE Y Compressor YELLOW G Fan GREEN W Heat OR Emergency Heat RED O B Reversing Valve ORANGE EC Economy Input GREEN Zone ONE only SmartLINK COMM SPECIFICATIONS 3 DISPLAY OPERATION...

Страница 4: ...PMENT W1 EH AUX HEAT W1 Auxiliary Heat energizes while Y1 Y2 de energize at a supply temp cooler than 90 F after 6 minutes run time of Y1 Y2 only W1 Auxiliary Heat de energizes at a supply temp of 100...

Страница 5: ...1 Y2 will de energize at a supply temp cooler than 90 F after 6 minutes run time of Y1 Y2 W1 Auxiliary Heat remains energized until all heat calls are satisfied or the supply temp gets warmer than GAS...

Страница 6: ...ic Equipment Heat Pump Equipment Reversing valve energized in COOLING Reversing valve energized in HEATING Operates Aux Heat WITH compressor HP Only Operates Aux Heat WITHOUT compressor 2nd Stage Acti...

Страница 7: ...AS or ELECTRIC HEAT COIL RETURN AIR AIR FLOW INSTALL SAS AFTER the COIL but BEFORE the BLOWER HEAT PUMP Standard Electric Aux SUPPLY PLENUM ELECTRIC Auxiliary HEAT COIL RETURN AIR AIR FLOW ECOJAY Smar...

Страница 8: ...re foot SPRING DAMPERS use a motor to power the damper blade in ONE direction and a spring to move the blade in the opposite direction When power is applied to the damper the motor moves the blade Whe...

Страница 9: ...TEMP LO TEMP SUPPLY PURGE DELAY ECO FRESH AIR Setup Configuration BUILTINTOSMARTZONE 4XWILLAUTOMATICALLY ENERGIZEFANANDOPENFRESHAIRDAMPER ZONE4 DURING FRESHAIRRUNTIME FRESH AIR CONTROL FRESHAIRCANBEC...

Страница 10: ...ter clockwise until the bypass damper motor starts to run open ECOJAY damper GREEN light will flash ecojay PO PC COM 1 2 3 Connect the flexible tubing to the HIGH PRESSURE INLET as shown Pressure inle...

Страница 11: ...to maintain constant pressure inside the duct when zones open and close When the correct size bypass damper is installed and adjusted correctly it will be fully CLOSED when all zones are calling no ai...

Страница 12: ...SMARTZONE B DUAL FUEL ELECTRIC VLV O NORMAL FAN GAS LOCKOUT 2nd STAGE SMART LINK ZONES 5 8 ZONES 1 4 SMART LINK 1 GND 2 DIP SWITCH 6 should be set to ZONES 5 8 on secondary SmartZone 4X ONLY ZONE 5 to...