User manual ecoGEO
54
EN
Specification ecoGEO B/C 5-22
Units
ecoGEO
B/C1
ecoGEO
B/C2
ecoGEO
B/C3
ecoGEO
B/C4
Application
Place of installation
-
Indoors
Type of brine system
1
-
Geothermal / Aerothermic / Hybrid
Heating
-
✓
✓
✓
✓
HTR - High temperature recovery system
-
✓
✓
✓
✓
Integrated active cooling
-
--
✓
✓
Passive outdoor cooling control
-
--
✓
--
✓
Performance
Compressor range of modulation
%
25 to 100
Heating power
2
, B0W35
kW
5,8 to 25
COP
2
, B0W35
-
4,9
Active cooling power
2
, B35W7
kW
--
6 to 22
EER
2
, B35W7
-
--
5
Maximum unassisted DHW temperature
°C
58
Maximum assisted DHW temperature
5
°C
70
Noise emission level
6
db
35 to 46
Energy label /
η
s with average temperature control
--
A+++ / 187%
Operation
limits
Heating outlet temperatura range
°C
10 to 60 (Max setpoint 60°C)
Cooling outlet temperatura range
°C
4 to 35 (Min setpoint 7°C)
Brine inlet temperature in heating mode range
°C
-25 to +35
Brine outlet temperature in cooling mode range
°C
10 to 60
Cooling circuit pressure min / max
bar
2 / 45
Production / Pre-load circuit pressure
bar
0,5 to 3 / 1,5
Brine / Pre-load circuit pressure
bar
0,5 to 3 / 0,7
Maximum DHW storage tank pressure
bar
8 (Only for ecoGEO C)
Working fluids
Refrigerant R410A load
kg
1,70
2,00
Compressor oil type / load
kg
POE / 1,18
Control
electrical data
1/N/PE 230 V / 50-60 Hz
8
-
✓
Maximum recommended external protection
9
A
C16A
Transformer primary circuit fuse
A
0,5
Transformer secondary circuit fuse
A
2,5
Electrical data:
Single phase
1/N/PE 230 V / 50-60 Hz
8
-
✓
Maximum recommended external protection
9
A
C50A
Maximum consumption
2
, B0W35
kW/A
5,6/28,2
Maximum consumption
2
, B0W55
kW/A
7,8/39,2
Starting current min/max
7
A
6,1/15,7
Correction of cosine φ
-
0,96-1
Electrical data:
Three phase
3/PE 400 V / 50-60 Hz
8
-
✓
Maximum recommended external protection
9
A
C20A
Maximum consumption
2
, B0W35
kW/A
5,6/8
Maximum consumption
2
, B0W55
kW/A
7,8/11,2
Starting current min/max
7
A
2/5,2
Correction of cosine φ
-
0,96-1
Dimensions
and weight
Height x width x depth
mm
ecoGEO B: 1060x600x710
ecoGEO C: 1804x600x710
Empty weight (without assembly)
Kg
B: 185
C: 247
B: 193
C: 255
B: 185
C: 247
B: 193
C: 255
1.
Replacing or combining the geothermal collector with one or more ecoGEO AU12 aerothermal units. Refer to the ecoGEO AU12 aerothermal
units manual for more detailed information.
2.
In compliance with EN 14511, this includes the consumption of the circulation pumps and the compressor driver.
3.
Considering brine and production flows of 2500 l/h.
4.
Considering a heat ramp of 20°C to 50°C in absence of consumption.
5.
Considering support provided by the emergency electrical resistor or the HTR system. Maximum DHW temperature with the HTR system can
be limited by the compressor discharge temperature.
6.
In compliance with EN 12102, this includes the acoustic insulation kit of the compressor.
7.
Starting current depends on working condition of the hydraulic circuits.
8.
The admissible voltage range for proper operation of the heat pump is ±10%.
9.
Maximum consumption can vary significantly according to working conditions, or if the compressor's range of operation is restricted. Refer
to the technical service manual for more detailed information.