background image

4

Engine Switch

LCD Screen

IOT Reset Switch

AC Power Button
AC Output Sockets

Starter Grip

Carbon Monoxide Alert Light

Engine Oil Alert Light

Electric Start Switch

Extra Battery Port (XT150)

Ground Terminal

Carbon Monoxide Alert Light: 

When the carbon monoxide sensor detects that the concentration of 

carbon monoxide is about to exceed the standard, the generator will automatically stop and the carbon 
monoxide alert light will flash for 5 minutes. During this course, the generator cannot be started. 

Air Filter

Rechargeable Battery

Oil Drain Bolt

Spark Plug

Engine Oil Dipstick

Содержание Smart Generator

Страница 1: ...EcoFlow Smart Generator User Manual ...

Страница 2: ......

Страница 3: ...esponsible for any incorrect usage and all the consequences arising therefrom EcoFlow hereby disclaims any liability for any losses due to the user s failure to use the product according to the User Manual Subject to compliance with laws and regulations our company has the final right to interpret this document and all documents of and related to this product Any update revision or termination of ...

Страница 4: ...he DELTA Max Extra Battery Pack or the DELTA Pro Extra Battery Pack 2 4 5 Using the App 2 4 6 Application Range 2 4 7 Special Requirements 3 1 Checking the Spark Plug 3 2 Adjusting the Carburetor 3 3 Replacing the Engine Oil 3 4 Air Filter 3 5 Fuel Filter Strainer 3 6 Muffler 1 1 Safety Warning 1 2 Safety Instructions 1 3 Important Labels 19 20 20 21 5 Faults and Troubleshooting 6 Parameters and S...

Страница 5: ... refueling Do not smoke when refueling Switch off the engine before refueling Keep any combustibles at least 1m 3ft away Do not use indoors and keep away from doors windows and vents Danger Warning Caution Earthing the Generator Connect the Generator to the Electrical System The generator is equipped with system grounding which is used to connect the generator s frame components to the ground term...

Страница 6: ...2 1 3 Important Labels Please refer the following stickers carefully before starting to use the product ...

Страница 7: ...3 Maintenance Cover 2 1 Appearance Description 2 Quick Start Fuel Cap Fuel Cap Breather Valve Muffler ...

Страница 8: ...50 Ground Terminal Carbon Monoxide Alert Light When the carbon monoxide sensor detects that the concentration of carbon monoxide is about to exceed the standard the generator will automatically stop and the carbon monoxide alert light will flash for 5 minutes During this course the generator cannot be started Air Filter Rechargeable Battery Oil Drain Bolt Spark Plug Engine Oil Dipstick ...

Страница 9: ...keep flashing if it is successfully connected to the Internet the icon will stay on See Section 5 for more troubleshooting steps Error Code Please refer to the EcoFlow app for specific information on error codes ECO Mode In ECO mode the Smart Generator will adjust its rotational speed to match the output power demand in order to conserve fuel and reduce noise This is the default mode You can modif...

Страница 10: ...y close the fuel cap after refueling Danger Clean away the residual fuel with a clean and soft cloth after refueling to avoid damage to the rubber shell Please use unleaded fuel rather than leaded fuel which may severely damage the internal parts of generator Take off the fuel cap and fill up until the red indicator Recommended fuel unleaded fuel Fuel tank capacity 1 05 gal 4 L Caution Open fuel c...

Страница 11: ...pecified amount of recommended engine oil and screw the lid and oil dipstick closed tightly Reinstall the maintenance cover and turn the knob to Closed Recommended engine oil SAE SJ 10W 40 Grade of recommended engine oil SJ or higher Oil capacity 0 1 gal 0 38 L Caution Rechargeable Battery Connection The generator cannot be started by the Electric Start switch unless connected to the internal batt...

Страница 12: ... level is low the engine oil alarm system may shut off the engine 1 Unscrew the lid take out the oil dipstick and wipe it clean 2 Dip the oil dipstick into the oil filler without screwing it in and check the oil level 3 Add the recommended amount of engine oil if the oil level is low 4 Screw the oil dipstick and lid firmly shut Make sure there are no engine oil leaks a Check the fuel level Take of...

Страница 13: ...5 Tips When the ambient temperature is below 32 0 C the engine will need to warm up for three minutes after being started during which time no load should be loaded Read the Safety Guidelines before use Do not use the generator in a closed space as the exhaust fumes may result in a loss of consciousness or even death Use it in a well ventilated place Do not connect the AC Output Socket with any el...

Страница 14: ...ap breather valve knob to OFF 2 4 2 Turning off Caution Warning Make sure that all electrical equipment including wires and plugs are in good condition before being connected to the generator and confirm that all loads carried by the generator are within the rated load range and that the load current is within the rated current range Tips Make sure that the generator is grounded If any electrical ...

Страница 15: ...tery Connection Cable 4 Switch on the DELTA Max Extra Battery or DELTA Pro Extra Battery and it will send a request to the generator to recharge The generator will respond and start recharging 5 When the DELTA Max Extra Battery or DELTA Pro Extra Battery is fully recharged it will send a request to the generator to stop charging The generator will respond and stop DC recharging Tips The DELTA Pro ...

Страница 16: ...se electronic devices If this generator is used to supply power to medical devices it is recommended to consult with the corresponding equipment manufacturers and technicians first This is because some electronic equipment or general purpose machines in hospitals require a strong current upon startup and may not be able to use the generator Please contact the equipment manufacturer for confirmatio...

Страница 17: ... plug to prevent the generator from starting up Do not use the generator such in poorly ventilated places such as rooms rail tunnels or caves Be sure to keep the working area well ventilated Exhaust gas from the generator contains toxic carbon monoxide fumes Inhaling these fumes may lead to shock loss of consciousness or even death Generator Engine Oil Check Add Check Add Check Adjust Check Adjust...

Страница 18: ...sion standard Standard spark plug A5RTC Spark plug clearance 0 15 0 3 mm Tips The engine may be damaged if the spark plug is not at the correct clearance height 3 1 Checking the Spark Plug Removing the spark plug Spark plug clearance 1 Turn the maintenance cover knob to and take off the maintenance cover 2 Take off the spark plug cap 3 Use the spark plug socket and revolve it counterclockwise to r...

Страница 19: ... very high Please take care not to get scalded when draining the oil 3 3 Replacing the Engine Oil Caution Warning Warning Do not tilt the generator when adding engine oil to prevent damage to the generator due to adding excessive oil 1 Turn the maintenance cover knob to and take off the maintenance cover 2 Take off the screws and the air filter cover 3 Take off the foam filter element 4 Clean the ...

Страница 20: ...e sure to tighten the fuel cap 1 Unscrew the bolts 2 Take off the muffler cap muffler block and spark plug arrestor 3 Clean the carbon deposits on the muffler block and the spark plug arrestor gently with a steel wire brush to avoid any damage or scratches to the muffler block and spark plug collector 4 Check whether the muffler block or the spark plug arrestor is damaged and replace it if damaged...

Страница 21: ...tank and reinstall the fuel cap 3 Start the generator The remaining fuel will be used up in about 20 minutes The generator will turn off when there is no fuel left Do not connect any electrical equipment to the generator The time it takes for the generator to run depends on the remaining amount of fuel inside the fuel tank 4 Turn the maintenance cover knob to and take off the maintenance cover 5 L...

Страница 22: ...the table below before using again 4 4 Use after storage Storage Duration Recommended Servicing Procedure to Prevent Difficult Startups Evacuate the fuel and inject fresh fuel Drain the fuel from Sediment Bowl No preparation needed Evacuate the fuel and inject fresh fuel Drain the fuel from Carburetor Drain Cup Drain the fuel from Sediment Bowl Evacuate the fuel and inject fresh fuel Drain the ori...

Страница 23: ...lated problems Remove the problem load shut down and restart DC overload protection Load related problems Remove the problem load shut down and restart Over temperature protection The air inlet is blocked or the ambient temperature is too high or the load is too large Check the air inlet or remove it from the high temperature environment or reduce the load 5 Faults and Troubleshooting Communicatio...

Страница 24: ...ne model Engine type Engine displacement Type of fuel Volume of fuel tank Generator engine oil volume Continuous Working Time Noise Level at a distance of 7 meters Model of spark plug Start mode R80 i Single cylinder four stroke forced air cooling overhead valve 80 CC Unleaded fuel 1 06 gal 4 L 0 21gal 0 38 L 3 5 Hr full load 56 67 dB full load A5RTC TORCH Electric start 7 Package List Extra Batte...

Страница 25: ...21 8 Circuit Diagram ...

Страница 26: ...warrantable condition exists Rato will repair your small off road engine equipment at no cost to you including diagnosis parts and labor The exhaust and evaporative emissions control system on your small off road engine equipment is war ranted for two years If any emissions related part on your small off road engine equipment is defective the part will be repaired or replaced by Rato As the small ...

Страница 27: ...r to the first scheduled replacement the part must be repaired or replaced by Rato according to Subsection 4 below Any such part repaired or replaced under warranty must be warranted for the remainder of the period prior to the first scheduled replacement point for the part 4 Repair or replacement of any warranted part under the warranty provisions must be performed at no charge to the owner at a ...

Страница 28: ...eactor iii Exhaust manifold 7 Particulate Controls i Traps filters precipitators and any other device used to capture particulate emissions 8 Miscellaneous Items Used in Above Systems i Electronic controls ii Vacuum temperature and time sensitive valves and switches iii Hoses belts connectors and assemblies e Emission Warranty Parts List for Evap 1 Fuel Tank 2 Fuel Cap 3 Fuel Lines for liquid fuel...