background image

YVG

YVGS

T

P

SPGmin

BLUE

YELL

OW

-GR

EEN

BLACK

BROWN

CO

NT

RO

LE

 D

'ET

AN

CH

EIT

I

CO

NT

RO

L D

E E

ST

AN

QU

ID

AD

PREDISPOSICION

PR

EV

U P

OU

R L

E

PREDISPOSED LE

KA

GE

 CO

NT

RO

L

PREDISPOSIZIONE CO

NT

RO

LL

O D

I T

EN

UT

A

230V

400V

FMV

KMV

R

S

T

NO

3

M

MV

UV

W

HLF

LINE

LO

AD

Z

SAL

FU

ER

HLB

TV

P

T

SP

A

Q

HLF

TELERRUPT

OR MO

TOR 

VENTILA

TOR

CONT

AC

TEUR MO

TEUR 

VENTILA

TEUR

RE

M

OT

E C

ON

TR

OL

 SW

ITC

H (

FA

N M

OT

OR

)

CONT

AT

TORE MO

TORE 

VENTILA

TORE

KMV

FMV

HLB

SPGmin

RELE' 

TERMIC

O MO

TORE 

VENTILA

TORE

MO

TOR 

THERM

AL RELA

Y (F

AN MO

TOR)

RELAIS 

THERMIQUE MO

TEUR 

VENTILA

TEUR

RELE' 

TERMIC

O MO

TOR 

VENTILADOR

LA

M

PA

DA

 D

I B

LO

CC

O

LO

CK

-O

UT

 LA

M

P

LA

M

PE

 D

E S

EC

UR

ITE

ESPIA DE BL

OQUEO

YVGS

YVG

FU

MV

TV

Q

Z

TR

ANSFORM

ATEUR D'

ALL

UM

AGE

MO

TORE 

VENTILA

TORE

TR

ASFORM

AT

ORE

IGNITION 

TR

ANSFORMER

TR

ANSFORM

ADOR

MO

TOR F

AN

MUTEUR 

VENTILA

TEUR

MO

TOR 

VENTILADOR

FUSIBLE FUSIBLE

ST

S

SP

A

ST

C

INTERRUT

TORE GENER

ALE C

ON FUSIBILE

INTERRUPTEUR GENER

AL A

VEC FUSIBLE

IN

TE

RR

UP

TO

R G

EN

ER

AL

 CO

N F

US

IBL

E

FIL

TR

O D

E P

RO

TE

CI

ON

  A

NT

ID

IST

UR

BIO

FIL

TR

O A

NT

ID

IST

UR

BO

AN

TJ

AM

M

IN

G F

ILT

ER

MAIN SWIT

CH 

WITH FUSE

FIL

TR

E A

NT

IPA

RA

SIT

ES

FUSE

FUSIBILE

SAL

PRESSOST

AT

O GAS DI MINIM

A

GAS PRESSURE SWIT

CH MIN

PRESSOST

AT GAZ PRESSION MIN

PRESOST

AT

O GAS DE MINIM

A PO

T.

EL

EC

TR

OV

AL

VU

LA

 G

AS

 D

E S

EG

UR

ID

AD

EX

TR

A SAFE

TY GAS SOLENOID 

VAL

VE

EL

ET

TR

OV

AL

VO

LA

 G

AS

 D

I S

IC

UR

EZ

ZA

EL

EC

TR

OV

AN

NE

 G

AZ

 D

E S

EC

UR

ITE

SAFE

TY 

THERMOST

AT

THERMOST

AT DE SECURITE

TERMOST

AT

O DE SEGURID

AD

TERMOST

AT

O DI SICUREZZA

TE

RM

OS

TA

TO

 CA

LD

ER

A

AIR PRESSURE SWIT

CH

PRESSOST

AT

O ARIA

INTERRUPT

OR DE LINEA

INTERRUPTEUR DE LIGNE

BOILER 

THERMOST

AT

TE

RM

OS

TA

TO

 CA

LD

AI

A

PRESOST

AT

O AIRE

PRESSOST

AT AIR

THERMOST

AT CHA

UDIERE

WORKING SWIT

CH

INTERRUT

TORE DI LINEA

ER

EL

ET

TR

OD

O D

I R

IVE

LA

ZIO

NE

IO

NI

SA

TIO

N P

RO

BE

EL

EC

TR

OD

E D

'IO

NI

SA

TIO

N

EL

EC

TR

OD

O D

E I

ON

IZA

CI

ON

EL

ET

TR

OV

AL

VO

LA

 G

AS

 

GAS SOLENOID 

VAL

VE 

EL

EC

TR

OV

AN

NE

 G

AZ

 

EL

EC

TR

OV

AL

VU

LA

 D

E G

AS

 

HLF

LA

M

PA

DA

 D

I F

UN

ZIO

NA

M

EN

TO

W

OR

KIN

G L

AM

P

LA

M

PE

 D

E F

ON

CT

IO

NN

EM

EN

T

ES

PIA

 D

E F

UN

CI

ON

AM

IEN

TO

3

1

2

4
3

7

S
R

5

T

1

6

P

T

ST

S

P

T

ST

C

8

50 H

z 400V

R

PE

T

S

FMV

95

96

N

N

2

12

TO

T. SHEE

T

SHEE

T

DESIGNER

DESCRIPTION

DA

TE FIST CREA

TION

CODE

SIGNA

TURE

R&D DEP

AR

TMENT

CO

NT

RO

LL

ER

Ec

o

fl

am

 B

ru

ci

at

or

i

SER

VOMO

TOR

FL

AM

E S

EN

SO

R

S.p

.A

ECN FIRST CREA

TION

BY T

ERM

 LAW

S W

E RE

SER

VED

 TH

E PR

OPE

RTY O

F TH

IS W

IRIN

G D

IAG

RAM

 W

ITH

 PRO

HIBI

TIO

N O

F U

SE A

ND R

EPR

ODU

CTIO

LE

AK

AG

E C

ON

TR

OL

CO

NT

RO

L B

OX

DA

TE

 EC

N M

OD

IC

AT

IO

N

M

OD

IFI

CA

TIO

N D

ES

CR

IPT

IO

N

EC

N M

OD

IFI

CA

TIO

N

MA

X GAS 500 P 

A.POZZ

OBON

18-02-2010

1

420110020100

1

   A.RIGONI

 

ER

RBA10P

M010

LANDIS L

GB21-LME21

PREDISPOST

O

F

1

E

D

2

3

4

C

B

A

1

2

3

4

5

6

7

8

F

E

D

5

6

7

C

B

8

A

LANDIS  L

GB 21-LME 21

12

4

3

11

6

5

7

8

9

10

32

12

31

RU

ES

FR

EN

IT

420010318203  

Max Gas 350 - 500 P/P AB 

63

Содержание MAX GAS 350 P AB

Страница 1: ...X GAS 350 P AB MAX GAS 500 P MAX GAS 500 P AB Low Nox 420010318203 02 08 2011 BRUCIATORI DI GAS AD ARIA SOFFIATA BLOWN AIR GAS BURNERS BRULEURS GAZ A AIR SOUFFLE QUEMADORES DE GAS DE AIRE SOPLADO IT E...

Страница 2: ...er and regulations Working of the burner p 17 Control box up cycle p 18 Adjusting air gas p 19 PAB minimal gas adjustment p 20 Air servomotor adjustment p 20 Regulating the combustion p 21 22 Adjustin...

Страница 3: ...200 200 100 300 400 300 400 500 600 0 1 2 3 4 5 6 7 8 9 mbar kW kcal h x 1000 MAX GAS 350 P AB MAX GAS 500 P AB 500 WORKING FIELDS Output Backpressure in comb chamber OPERATING FEATURES Model Max Gas...

Страница 4: ...o control that this last is perfectly sealed Also verify that the chimney is not obstructed Open the gas cock and carefully bleed the piping through the pressure gauge connector then check the pressur...

Страница 5: ...d off disconnect the flame detection cable from relevant electrode so as to make the valve to automatically shut off at the ignition after the safety time Make a reading on the gas meter Start the bur...

Страница 6: ...lays KL Low fire LK Air damper LKP Air damper position LP Air pressure switch LR Load controller M Fan motor R Control thermostat pressurestat SA Actuator STB Safety limit thermostat Si External pre f...

Страница 7: ...stment of burner no fuel Faulty ignition equipment 3 blinks on LP faulty Loss of air pressure signal after t10 LP welded in normal position 4 blinks on Extraneous light when burner is started up 5 bli...

Страница 8: ...for air damper position on burner s shutdown total close 0 II Adjusting cam ORANGE for opening position in ignition and Low Flame by the screwdriver III Adjusting cam RED for opening position in High...

Страница 9: ...ng the combustion head figure to suit the power required as shown in figure 3 dose the gas by regulating the gas ramp see figure in the ramp manual Low flame setting 1 after regulating the maximum pow...

Страница 10: ...in head 13 mbar Gas pressure in head Head position ADJUSTING THE AIR PRESSURE SWITCH The air pressure switch must be adjusted so that an insufficient air flow does not allow the CO value to exceed 1...

Страница 11: ...C microammeter with a 0 50 or 0 100 A dial When the burner is run ning and is properly adjusted the value read must be steady and never be smaller than 1 5 A LME 11 21 22 LANDIS LME11 LME21 22 min 1 5...

Страница 12: ...13 14 15 16 7 7 7 8 9 10 11 12 EN 420010318203 Max Gas 350 500 P P AB 24...

Страница 13: ...urner connected That the gas pressure is correct and the gas cock open That the control systems are correctly connected If all these conditions are present start the burner by pressing the release but...

Страница 14: ...ING SWITCH INTERRUTTORE DI LINEA ER ELETTRODO DI RIVELAZIONE IONISATION PROBE ELECTRODE D IONISATION ELECTRODO DE IONIZACION ELETTROVALVOLA GAS GAS SOLENOID VALVE ELECTROVANNE GAZ ELECTROVALVULA DE GA...

Страница 15: ...XTRA SAFETY GAS SOLENOID VALVE ELETTROVALVOLA GAS DI SICUREZZA ELECTROVANNE GAZ DE SECURITE SAFETY THERMOSTAT THERMOSTAT DE SECURITE TERMOSTATO DE SEGURIDAD TERMOSTATO DI SICUREZZA TERMOSTATO CALDERA...

Страница 16: ...ri SERVOMOTOR FLAME SENSOR S p A ECN FIRST CREATION BY TERM LAWS WE RESERVED THE PROPERTY OF THIS WIRING DIAGRAM WITH PROHIBITION OF USE AND REPRODUCTION LEAKAGE CONTROL CONTROL BOX DATE ECN MODICATIO...

Страница 17: ...PRESSION MIN GAS PRESSURE SWITCH MIN PRESSOSTATO GAS DI MINIMA SAL FUSIBILE FUSE FILTRE ANTIPARASITES MAIN SWITCH WITH FUSE ANTJAMMING FILTER FILTRO ANTIDISTURBO FILTRO DE PROTECION ANTIDISTURBIO INTE...

Страница 18: ...flam Bruciatori SERVOMOTOR FLAME SENSOR S p A ECN FIRST CREATION BY TERM LAWS WE RESERVED THE PROPERTY OF THIS WIRING DIAGRAM WITH PROHIBITION OF USE AND REPRODUCTION LEAKAGE CONTROL CONTROL BOX DATE...

Страница 19: ...MMING FILTER FILTRO ANTIDISTURBO FILTRO DE PROTECION ANTIDISTURBIO INTERRUPTOR GENERAL CON FUSIBLE INTERRUPTEUR GENERAL AVEC FUSIBLE INTERRUTTORE GENERALE CON FUSIBILE STC SPA STS FUSIBLE FUSIBLE MOTO...

Страница 20: ...0 1 1 2 3 4 5 6 7 8 9 10 17 16 11 12 13 15 14 18 19 20 22 21 MAX GAS 350 P MAX GAS 500 P 23 24 25 27 28 26 29 30 31 32 33 34 35 36 350 P RU ES FR EN IT 420010318203 Max Gas 350 500 P P AB 68...

Страница 21: ...1 I II 1 2 3 4 5 6 7 8 9 10 17 16 11 12 13 15 14 18 19 20 22 MAX GAS 350 P AB MAX GAS 500 P AB 25 350 P 21 23 24 27 28 26 29 30 31 32 33 34 35 36 37 RU ES FR EN IT 420010318203 Max Gas 350 500 P P AB...

Страница 22: ...DE PRESSION SOPORTE ACCESO DE PRESI N 65324691 65324691 21 CABLE D IONISATION CABLE DE IONIZACION TC 65320946 65320946 TL 65320947 65320947 22 CABLE D ALLUMAGE CABLE DE ENCENDIDO TC 65320944 65320944...

Страница 23: ...20 95 4 65324691 65324691 21 9 4 U 5 TC 65320946 65320946 TL 65320947 65320947 22 9 04 1 TC 65320944 65320944 TL 65324194 65324194 23 5 4 U 5 65320950 65320950 24 5 04 1 65324331 65324331 25 1 5 9 2 1...

Отзывы: