11
420010251101
M aior P 45/60/80/120 PR SW
EN
MAXIMUM LENGTH OF SUCTION LINES FOR TWO-PIPE SYSTEM
To correct length of pipes is calculated by summing up the length of all vertical and horizontal right sections
and bends. The static suction head will be the distance between the non-return valve and the
burner’s pump axle. The depression must not be greater than 0.45 bar; should it be higher, some damages
could occur to the pump, with consequent increase in mechanical noises and ,eventually, a failure.
H
(m)
ø 10 mm ø 12 mm
0
0,5
1
2
3
3,5
32
36
40
48
56
60
90
90
90
90
90
90
ø 14 mm ø 16 mm
22
25
30
35
38
40
38
45
50
60
70
80
AS 67 / AN 77
(m)
AJ 6
(m)
H
H
H
(m)
ø 10 mm ø 12 mm
0
0,5
1
2
3
3,5
25
21
18
10
5
---
70
62
54
38
20
10
ø 14 mm ø 16 mm
25
20
18
10
5
2
45
38
33
20
10
4
AS 67 / AN 77
(m)
AJ 6
(m)
Two-pipe lift system
Two-pipe siphon feed system
Pipe length
Pipe length
NOZZLE OUTPUT
TYPE : MONARCH F80-BPS
NOZZLE
PUMP PRESSURE
RETURN PRESSURE BAR
20 bar
GPH
0
4,218
8,436
12,654
16,872
CAPACITY kg/h
4.00
7,52
8,91
13
19
-
22,24
4.50
7,52
8,91
13
21,16
-
24,96
5.00
7,52
9,33
13,38
21,39
-
27,68
5.50
7,52
9,36
13,93
25,6
30
30,56
6.00
9,2
11,42
13,93
17,8
33,45
33,28
6.50
9,2
9,49
11,42
20
36,19
36,00
7.00
9,74
13,38
17,27
24,5
39
38,88
7.50
9,74
13,38
18,66
31,2
41,82
41,6
8.00
9,74
10,87
15,6
25,64
44,55
44,16
9.00
11,16
15
18,4
25,64
36,77
49,92
9.50
12
13,38
18,94
29,53
52,9
52,64
10.50
12,8
13,93
22,29
33,7
58,55
58,24
12.00
13,93
15
22,29
34
66,9
66,56
13.80
16,72
20
31,2
57,9
76,89
76,48
15.30
16,72
20
29,27
43,46
72,54
84,8
17.50
20,9
23,42
36,5
66,27
-
96,96
19.50
22,29
29,53
43,49
64,6
108,74
108,16
21.50
22,8
27,3
40,15
61,28
120
119,04
OUTPUT kg/h