installation and user instructions

All instructions must be handed to user for safekeeping

Revision A - 06/09

Country(s) of destination - GB/IE

eko 

2

0

4

0

fuel effect gas fire

Содержание eko 2040

Страница 1: ...installation and user instructions All instructions must be handed to user for safekeeping Revision A 06 09 Country s of destination GB IE eko 2040 fuel effect gas fire...

Страница 2: ...ll these instructions before commencing installation This appliance must be installed in accordance with the rules in force and only used in a sufficiently ventilated space The appliance is designed f...

Страница 3: ...sult all instructions before installation and use of this appli ance This appliance is intended for decorative purposes This appliance is free from any asbestos material Refractories and fuel bed are...

Страница 4: ...before installation by using a smoke pellet or similar to ensure proper draw and that leakage is not evident at any joints Repair and re test as necessary before the appliance is installed 2 0 3 0 A...

Страница 5: ...to 470mm high Opening DEPTH should be 355mm or greater Opening DEPTHS include any plaster or infill panels which form part of the installation This appliance requires a natural draught flue system wh...

Страница 6: ...ack of ventilation is the problem if not it will be the flue at fault Installation of an air brick is the best solution Any ventilation fitted must comply with BS 5871 part 2 and BS 5440 part 2 Ventil...

Страница 7: ...the fibre rawlplugs into the fixing holes and then using the fixing screws provided secure the burner unit to the hearth base of builders opening Remove any protective film from the lower decorative t...

Страница 8: ...ny circumstances the electric spark fails the pilot may be lit man ually by proceeding with the ignition sequence as previously described and after turning the control knob through the spark position...

Страница 9: ...ay up the flue Any smoke returning into the room indicates that spillage is occurring If the initial spillage test fails run the fire for a further 10 minutes and repeat the test When the test has bee...

Страница 10: ...rt stubborn marks may be removed by gently rubbing with a fine abrasive paper i e wet and dry paper It is not recommended to use water unless the entire body can be removed from the fire and rinsed un...

Страница 11: ...ty piezo unit replace Debris shorting out electrode clean Fire runs for a time and then cuts off Excessive room draught or flue pull rectify Loose or faulty thermocouple rectify ODS system in operatio...

Страница 12: ...embossed paper may discolour if fitted too close to the fire See relevant section for further details on clearances to combustibles No combustible material or flooring should protrude onto the hearth...

Страница 13: ...r Republic of Ireland ventilation may be required see IS 813 ICP3 IS 327 and any other rules in force FUEL BED LAYOUT The appliance is supplied with 13 individually wrapped hand finished ceramic pebbl...

Страница 14: ...face downwards 3 Next place the pebbles marked L and M as shown The letters are on the bot tom of the pebbles and should face down wards The fuel bed layout is now complete The fire is designed to op...

Страница 15: ...ith the previous section If pilot disturbance is not the cause then the ODS safety system may be in operation Switch the appliance OFF call in your installer to check the flue and ventilation and carr...