15
tected, an audible alarm with 4 beeps, pause 5
seconds and 4 beeps will occure. The red LED will
flash continuously and rapidly. Meanwhile, the
CO detector will send an alarm report to the us
-
er’s controller and also the CO dectecor will send
an alarm report while the alarm off.
4.
Error Mode: If the CO detector beep once and
yellow LED flash three times every minute, it in-
dicates the CO detector is not working properly.
Please call the technical assistance.
5.
Low battery warning Mode: The yellow LED will
flash once every minute with a “beep” sound.
6.
Low sensitivity Mode: The yellow LED will flash
twice every minute with a “beep” sound. It in-
dicates the CO detector has internal problem,
please call the technical assistance.
7.
Tamper Mode: The yellow LED will go solid and
the detector will emit a short beep every minute
untill the CO detector is mounted back to the
bracket properly.
8.
End of life signal Mode: The yellow LED will flash
four times every minute with a short “beep”
sound. It indicates the CO detector is reaching to
the end of useful life, please replace with a new
unit.