10
2.7 Dehumidification
2.7.1 When indoor temperature is higher than a certain temperature value, and higher
than(set temperature
),
unit operates in cooling mode and outdoor fan speed is the same
with the speed in cooling operation
;
or unit operates in dehumidifying operation according to
indoor temperature and outdoor fan motor is at low speed level.
When indoor temperature is higher than the upper limit value, compressor operates by a
certain prescribed frequency.
When indoor temperature is between upper limit temperature and lower limit temperature
,
compressor operates by a prescribed frequency.
When indoor temperature is lower than lower limit temperature, compressor stops.
2.7.2 Fan motor runs at low speed level.
2.7.3 Freeze-prevention control: same as cooling mode.
2.7.4 Dry Mildew Proofing Operation: same as cooling mode.
2.8 Other functions
2.8.1 Timelag protection function for compressor
In order to protect compressor
(
expect for defrost mode
)
,there will be a 3-minute delay to
restart when compressor stops from working condition. And there is still 3 minute delay
when the compressor is firstly started.
2.8.2 Automatic restart
This function refers to
:
When the electricity comes again after power failure, the unit is
required to get back to the condition before power failure automatically. The mode, set
temperature, air refresh, sleep, lock for the safety of children, humidification and air
ventilation all keep in the same condition before power failure.
This function can be set or cancelled through EEPROM device on electric board or the
installation of peripheral circuit.
2.8.3 Independent air refresh function
Press “air refresh”button on remote controller when the unit is in off status, the unit is in Fan
Sweep mode. Press this button again, this function can be cancelled.
2.8.4.Timing on/off
1. Turn on the air conditioner on timer: The air conditioner will starts operation at the set
time.
“
time on
”
function is only effective for once in 24 hours. If user turns on the air condition
by pressing on/off button on the remote controller before the set time, then” timing on”
function will be cancelled. If user select “timing on” when the air conditioner is in on status,
the air conditioner will stop immediately and restart automatically at set time.
2. Timing off: The air conditioner will exit running at set time. ” timing off” function is only
effective for once in 24 hours. If user turns off the air condition by pressing on/off button on