7. Connect the hoses on the Fusion Tap to the units as follows:
The three hoses taped together are all inlet hoses, one white, one blue and
one black, ensure these are connected first.
a. 1/4” Blue hose: connect to Outlet port of Water Filter. Using extra blue hose
provided, connect the Inlet Port of the Water Filter to the outlet port of the
PLV via the brass adaptor supplied.
b. 1/4” Black hose connect to the 1/4” brass connector on the top of the Boil
Unit marked “Inlet”.
c. 1/4” White hose: connect to the 1/4” quick fit connector on top of the Chiller
Unit marked “Inlet”.
Then connect the following hoses:
d. 5/16” Copper Pipe: connect to the 5/16” brass connector on top of the Boil
Unit marked “Outlet”.
e. 1/4” Orange silicon hose: push-fit over the end of the extended copper pipe
marked “Vent” on Boil Unit.
f. 1/4” White hose: connect to the 1/4” quick fit connector on top of the Chiller
Unit marked “Outlet”.
Cut or extend all chiller hoses as necessary. Never install with sharp bends,
use a John Guest elbow if necessary.
8. Connect the mains water supply to the inlet port of the PLV using the
15mm Hex nipple and Crox nut supplied.
9. Connect the drain clamp supplied and fix to the waste S bend above the
water level using the rubber seal between the clamp and the waste pipe.
Push on the Opaque silicon tube.
To mains
water supply