- 7 -
Страница 1: ...ter your air conditioner Model information can be found on the CE label Please register your product online at www ecoair org For your future convenience record the model information below ____________________________________ MODEL NUMBER ____________________________________ SERIAL NUMBER ____________________________________ PURCHASE DATE ...
Страница 2: ...re present Any maintenance on the air conditioner must only be carried out after disconnecting from the electric mains supply Any repairs must be carried out by a suitably qualified engineer Ensure the air conditioner is connected to an earthed power supply of the correct rating Do not unplug the air conditioner whilst in operation Always use the control panel to start and stop the air conditioner...
Страница 3: ... and must be connected to the terminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the EARTH and must be connected to the terminal which is marked with the letter E or or coloured GREEN OR GREEN YELLOW 4 Always ensure that the cord grip is positioned an...
Страница 4: ...es for operation 1 Notices for use 3 Names and functions of each part 5 Operation of remote control 6 Emergency operation 10 Clean and care 11 Troubleshooting 13 Installation service Notices for installation 16 Installation dimension diagram 18 Install indoor unit 19 Install outdoor unit 21 Check after installation and test operation 22 Installation and maintenance of healthy filter 23 Do not disp...
Страница 5: ... the air intake or outlet Keep combustible spray away doors open for a long time vents of both the outdoor and indoor from the units more than 1m while operating the air conditioner units It can decrease the air conditioning It can de crease the air conditioning It can cause afire or explosion capacity capacity or cause a malfunction Please note whether the installed Don t step on the top of the D...
Страница 6: ...er of left right direction Louver of upward downward direction Don t insert your hands or stick into the air Don t blow the wind to animals and plants intake or outlet vents directly It can cause a bad influence to them Otherwise it will cause accident Don t apply the cold wind to the body for a Don t use the air conditioner for other purposes long time such as drying clothes preserving foods etc ...
Страница 7: ...y You may need to use alternative heating equipment Defrosting When outdoor temperature is low but high humidity frost will form on outdoor unit that will affect the heating resulting in the auto defrost function where the heating will stop for 8 10mins During the auto defrosting the fans of indoor and outdoor unit will stop During the defrosting the indoor indicator flashes the outdoor unit may e...
Страница 8: ...de DB WB o C Outdoor side DB WB o C Maximum cooling 32 23 43 26 21 15 Minimum cooling 21 Maximum heating 27 24 18 Minimum heating 20 5 6 The operating temperature range outdoor temperature for cooling unit is 10 48 for cooling and heating unit is 5 48 4 ...
Страница 9: ...or unit Air in Air out Outdoor unit Wireless remote control Air in Air out Power cable 7 Cool Dry Heat Set temp Run The pattern in displayer Remote control Front panel Filter Guide louver Wall pipe Bind tape Connection wire Drainage pipe 5 ...
Страница 10: ...and Sleep Off can be selected After powered on Sleep SLEEP button SLEEP Off is defaulted After the unit is turned off the Sleep function is canceled After Sleep function set up the signal of Sleep will display In this mode the time of timer can be adjusted Under Fan and Auto modes this function is not available By pressing this key you may select AUTO FAN 1 FAN 2 FAN 3 or FAN 4 and may FAN button ...
Страница 11: ... 7 ...
Страница 12: ...speed AUTO FAN LOW MID HIGH SUPER HIGH 5 Press and button to set swing mode ON OFF MODE FAN X FAN TEMP TIMER TURBO SLEEP LIGHT Guide for operation optional operation 1 Press SLEEP button set the sleep mode 2 Press TIMER button to set the scheduled timer on or timer off Introduction for special function About AUTO RUN When AUTO RUN mode is selected the setting temperature will not be displayed on t...
Страница 13: ...to lock or unlock the keyboard If the remote controller is locked the LOCK icon will be displayed on it in which case press any button the mark will flicker for three times If the keyboard is unlocked the mark will disappear About switch between Fahrenheit and Centigrade Under status of unit off press MODE and buttons simultaneously to switch C and F Changing batteries and notices 9 ...
Страница 14: ...se use the manual switch button At this time the unit will run at Auto mode but the temperature and fan speed cannot be changed The operation was shown as below To open the panel the manual switch is on the display box Turn on the unit At unit turned off press the button the unit will run at Auto mode immediately The microcomputer will accord to the indoor temperature to select Cooling Heating Fan...
Страница 15: ...t panel Clean the air filter Recommended once every three months NOTE In dusty environment more frequent cleaning will be required After taking off the filter do not touch the fin of indoor unit to avoid damage to the fins and cuts to fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out see Fig 4 a b a Pull open the front cover...
Страница 16: ...anged if remote is not working Check that the installation stand of the outdoor unit is not damaged If damaged please contact your installer Maintain after use Turn main power off Clean the filter clean the indoor and outdoor units panels Clear dust and obstructions from the outdoor unit Adopt a special shield to cover the outdoor unit to avoid rain water and dust from entering the unit where poss...
Страница 17: ...ng the filter If problem persists obtain a maintenance service from your installer Sound of water flow can be heard during The air conditioner is started when it is the operation running the compressor started or stopped running or the unit is stopped sometimes there is swoosh or gurgle this sound is due to refrigerant flowing and is not a malfuncti on In COOL mode sometimes the mist is emitted Wh...
Страница 18: ...einsert it Is it in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leakage in the room The air humidity is on the high side Condensing water over flowed The connection position of indoor unit drainage pipe is loosed If water leakage in outdoor unit When th...
Страница 19: ...ation will occur In dehumidifying mode indoor fan will stop in order to avoid condensed water to be vaporized again The air delivery is delayed during this action If unit is running in high humidity condition for a long time the moisture will be condensed on the air outlet grill and drip off Immediately stop all operations and plug out contact the dealer in following situations There is harsh soun...
Страница 20: ...uch as hot spring zones where a sulfured gas is generated Indoor Unit Installation Position Selection 1 The air inlet and outlet vent should be far from any obstruction make sure that air is well ventilated throughout the whole room 2 Select a position where the condensing water can be easily drained out and the place is easily connected for outdoor unit 3 Select a location where it is out of chil...
Страница 21: ... 2 Don t drag the power cable emphatically 3 It must be earthed and it should be connected to the special earth device operated by a qualified electrician The air switch must have the functions of magnetic tripping and heat tripping in order to protect the short circuit and overloading 4 The min distance from the unit and combustive surface is 1 5m 5 The appliance shall be installed in accordance ...
Страница 22: ... 18 ...
Страница 23: ... the hole to prevent the connection piping and wiring from being damaged when passing through the hole Install the water drainage pipe 1 The drain hose should be placed at a downward slant otherwise the water will fail to drain outward causing leakage from the indoor unit 2 Do not wrench or bend the drain hose or flood its end with water Connect indoor and outdoor electric wires 1 Open the surface...
Страница 24: ...1 and tailings 2 when routing both the wiring and piping 2 Gently route the piping from the body case wrap the piping electric wire water pipe with tape and pull them through the piping hole As show in Fig 8 3 Hang the mounting slots of the indoor unit on the upper tabs of the rear panel and check if it is firm enough As show in Fig 9 4 The height of the installed location should be 2 5metres or m...
Страница 25: ...ly shut 2 Connect joint of charging hose to vacuum pump 3 Fully open handle handle of Lo manifold valve 4 Open the vacuum pump to evacuate At the beginning slightly loosen joint nut of low pressure valve to check if there is air coming inside If noise of vacuum pump has been changed the reading of multimeter is 0 Then tighten the nut 5 Keep evacuating for more than 30mins and make sure the reading...
Страница 26: ...apacity It may cause condensation and dripping It may cause condensation and dripping It may cause electric malfunction or damage the part It may cause electric malfunction or damage the part It may cause electrical leakage It may cause electric malfunction or damage parts in the unit It may cause insufficient cooling heating capacity The refrigerant capacity is not accurate Test Operation 1 Befor...
Страница 27: ...ilter Fig c Fig d Cleaning and Maintenance Take out the healthy filter before cleaning and reinstall it after cleaning according to the installation instruction Pay special attention to that silver ion filter can t be cleaned with water while active carbon photocatalyst low temperature conversion LTC catalyst formaldehyde eliminator ca techin or mite killing filter can but can t with brush or hard...
Страница 28: ...ghtly from the illustration This warranty is in addition to and does not affect your statutory rights For after sales needs please visit www ecoair org service or email technical ecoair org or contact 44 0 845 474 3574 We recommend that you note the details of your purchase below and retain your original proof of purchase receipt with this manual Keep these documents safe in the event of a warrant...