5

USING THE DEHUMIDIFIER

 

When first using the dehumidifier, operate the unit continuously 24 hours.

How the Dehumidifier Operates

Moist, humid air is drawn over a cold refrigerated
dehumidifying coil. Moisture in the air condenses on
this coil and drains into a tank (or through a 
hose for continuous drain).
Dry, clean air is drawn through the condenser
where it is heated and discharged through the top grille
into the room.

 

It is normal for the surrounding air to 

become slightly warmer as the dehumidifier operates.

Automatic Defrost

When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.

In defrosting mode,the fan motor will run normally 
and the compressor stop running.

Choosing a Location

A dehumidifier operating in a basement will have little or 
no effect in drying an adjacent enclosed storage area, 

 

such as a closet, unless there is adequate circulation of 
air in and out of the area.

Do not use outdoors.

applications only. This dehumidifier should not be
used for commercial or industrial applications.

This dehumidifier is intended for indoor residential

Place the dehumidifier on a smooth, level floor
strong enough to support the unit with a full bucket
of water.

Allow at least 12–18 inches of air space on all sides
of the unit for good air circulation

 

(The

 

place

 

with

 

a

draught leaves the distance of the wall as 40 inches).

Place the dehumidifier in an area where the

temperature will not fall below 5°C. Or the coils
can become covered with frost, which may
reduce performance.

Use the dehumidifier to prevent moisture damage
for stored items.

Use the dehumidifier in a basement to help prevent
moisture damage.

The dehumidifier must be operated in an enclosed
area to be most effective.

Close all external doors, windows and other outside 
openings of the room.

When the dehumidifier operates please do not

 

cover the top grille

.

YES

NO

NOTE:

 

The dehumidifier has rollers to aid placement,

but it should only be rolled on smooth, flat surfaces.
Do not attempt to roll the dehumidifier on carpet or
over objects.

s

e

h

c

n

i

40

12-1

8 in

che

s

Содержание ECO DC10 MK2

Страница 1: ...preventative care on your part can save you a great deal of time and money over the life of your dehumidifier You ll find many answers to common problems in our troubleshooting section Review the chart of Troubleshooting Tips before calling your service engineers keeping your home safe and clean ECOAIR TECHNICAL SUPPORT UK TEL 44 845 388 0007 EMAIL technical ecoair org ...

Страница 2: ......

Страница 3: ...g 4 The appliance should not be installed in the bathroom 5 The appliance should be installed in accordance with national wiring regulations and must be positioned so that the plug is accessible invalidate the warranty 7 Before the first operation check if the float in the tank is at the correct position If the position is not correct correct this by hand 6 If the power cord is damaged it must be ...

Страница 4: ...erminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the EARTH and must be connected to the terminal which is marked with the letter E or or coloured GREEN OR GREEN YELLOW 4 Always ensure that the cord grip is positioned and fastened correctly If a 13A B...

Страница 5: ...rate in close proximity to walls or curtains etc The use of attachments or accessories not recommended or sold by the product distributor may cause personal or property hazards or injuries Keep the area around the warm air outlet sufficiently clean and make sure that it is not congested Do not place the power cord under a carpet Never install the unit in direct sunshine Prevent children from climb...

Страница 6: ...ill cycle off and the fan will Auto restart In the case of a power failure or interruption the unit will automatically restart in the settings 4 Tank full the tank is removed or not replaced securely continue to run until the frost disappears last used when the power is restored securely in position Control Panel Operation indicator Tank full light indicates tank needs to be emptied or is not secu...

Страница 7: ...of the area Do not use outdoors applications only This dehumidifier should not be used for commercial or industrial applications This dehumidifier is intended for indoor residential Place the dehumidifier on a smooth level floor strong enough to support the unit with a full bucket of water Allow at least 12 18 inches of air space on all sides of the unit for good air circulation The place with a d...

Страница 8: ...cally 1 Remove the tank Water Level The dehumidifier will turn off automatically when the tank is full or when the tank is removed or not replaced in the correct position The tank must be securely in position for the dehumidifier to work The FULL light will be on and the dehumidifier will not run if the tank is not in the correct position 2 Insert the drainage hose into drain spout 4 Replace the t...

Страница 9: ...he dehumidifier to operate NOTE Do not use a dishwasher to clean the water tank To remove Remove the tank and pour any water out To replace Slide and secure the tank into the dehumidifier Air filter The air filter should be checked and cleaned at least every 250 hours of operation or more often if necessary To remove Press the two buttons then pull out the filter To clean Clean the filter with war...

Страница 10: ...to the room Room temperature Moisture removal is best at higher room temperatures is too low Lower room temperatures will reduce the moisture removal rate Models are designed to be operated at temperatures above 5 C Area to be dehumidified The capacity of your dehumidifier may not be adequate is too large Doors and windows are open Close all doors and windows to the outside Dehumidifier has been r...

Страница 11: ...and wind up power cord When you do not use the unit for a long period we suggest you to take following steps to store the unit in good condition Model Rated Voltage Rated Frequency Rated Power Moisture Removal at 30 Operating Temperature Weight Tank Capacity 2 1L Automaticstop at about 2 0L ECO DC10 MK2 10L DAY SPECIFICATIONS LONG TERM STORAGE Please refer to nameplates for further details RH80 ...

Страница 12: ...ttempts to service or alter the unit will render this WARRANTY VOID The actual product may differ slightly from illustration For further information please contact 44 845 388 0007 This product has been manufactured to comply with the EC Directives 2006 95 EC and 2004 108 EC SERVICE AND WARRANTY TWO 2 YEAR LIMITED WARRANTY Save This Warranty Information ments Copyright Reserved WEE EC2601UR keeping...