- 7 -
Securing Cable Connections
Please use an insulated Philips screwdriver to tighten the cable connections.
Please secure all cable connections to the proper specification in order to ensure
good contact between the cable lugs and the terminals.
Over-tightening cable connections can cause terminal breakage and loose cable
connections can cause terminal meltdown or fire.
To ensure good contact between the cable lugs and the terminals, please use the
appropriate number of washers to allow for as much thread engagement as possible
without bottoming out the terminal bolt. The correct number of washers can be deter-
mined by hand-tightening the terminal bolt with just the cable lug in place and
observing the gap that is present. Use the number of washers needed so that the
washer stack is slightly larger than the observed gap.
It is important to ensure that the cable lug and the top surface of the terminal are in
contact. The washer(s) must be placed on top of the lug. Do not place the washer(s)
between the battery terminal and the cable lug as this can cause high resistance and
excessive heating
The parallel mode means that the positive pole
of the first lithium battery is connected to the
positive pole of the second cell, and the nega-
tive pole is connected to the negative pole, and
so on. The string voltage be as a single battery,
and the total discharge current be as the sum of
all batteries current.
Parallel
Содержание LIFEPO4 12V 100Ah