hydraulics
Plumbing
Magen eco-Spark
®
Installation manual. © 2012, all rights reserved
P a g e
|
18
PLUMBING
WATER INLET /OUTLET
Inlets are always connected to a lower end of the bank; Outlets to the opposite upper
corner (diagonally).
It is best to connect the inlet to the corner farthest from the pool, so that the outlet can
be as near the pool as possible, to reduce heat loss.
Using the “Reverse return” (Tichelmann) method would ensure balanced flow in all
collector banks.
BANKS IN SERIE
FEED
ROOF TILT
END
CAP
END
CAP
RETURN
SINGLE BANK SPLIT FEED
FEED
ROOF TILT
END
CAP
END
CAP
RETURN
END
CAP
END
CAP
BANKS IN SERIES
FEED
ROOF TILT
RETURN
BANKS IN SERIES