background image

3

Specifications & Performance Claims

Model EP 7130

Model EP 7140

Model Code

E7130

E7140

Rated Softening Capacity (Grains @ Salt Dose)

14,700 @ 2.9 lbs.

25,400 @ 8.0 lbs.

30,100 @ 13.1 lbs.

11,900 @ 2.4 lbs.

31,800 @ 9.1 lbs.

40,400 @ 15.8 lbs.

Rated Efficiency (Grains/Pound of Salt @ Minimum Salt Dose)

5,060 @ 2.9 lbs.

4,960 @ 2.4 lbs.

Water Used During Regeneration @ Minimum Salt Dose

2.3 gal. / 1,000 grains

3.4 gal. / 1,000 grains

Total Water Used Per Regeneration @ Maximum Salt Dose

35.2 gallons

41.6 gallons

Rated Service Flow Rate

7.5 gpm

9 gpm

Amount of High Capacity Ion Exchange Resin

.82 cu. ft.

1.16 cu. ft.

Pressure Drop at Rated Service Flow

13.4 psig

9.1 psig

Water Supply Max. Hardness

110 gpg

110 gpg

Water Supply Max. Clear Water Iron

8 ppm*

10 ppm*

Water Supply Pressure Limits (minimum / maximum)

20 - 125 psi  (137.9 - 861.8 kPa)**

Water Temperature Limits (minimum / maximum)

40 - 120 °F

Minimum Water Supply Flow Rate

3 gpm

Maximum Drain Flow Rate

2.0 gpm

Salt Storage Capacity

220 lbs.

Questions? Call Toll Free 1-800-693-1138

Monday- Friday, 7 AM - 6 PM CST

or visit www.ecopurewaterproducts.com

When you call, please be prepared to provide the model and serial number,

found on the rating decal, typically located on the rim below the salt lid hinges.

*

Capacity to reduce clear water iron is substantiated by WQA test data.  State of Wisconsin requires additional

treatment if water supply contains clear water iron exceeding 5 ppm.

**Canada working pressure limits: 1.4 - 7.0 kg/cm

2

.

These systems conform to NSF/ANSI 44 for the specific performance claims as verified and substantiated by

test data.

Variable Salt Dose:

The salt dose is selected by the electronic controls at regeneration time based on the

amount needed.

These models are efficiency rated.  The efficiency rating is valid only at the minimum salt dose.  These softeners

have a demand initiated regeneration (D.I.R.) feature that complies with specific performance specifications intended

to minimize the amount of regenerant brine and water used in their operation.
These softeners have a rated softener efficiency of not less than 3,350 grains of total hardness exchange per pound

of salt (based on sodium chloride) and shall not deliver more salt than their listed rating or be operated at a sus-

tained maximum service flow rate greater than their listed rating.  These softeners have been proven to deliver soft

water for at least ten continuous minutes at the rated service flow rate.  The rated salt efficiency is measured by lab-

oratory tests described in NSF/ANSI Standard 44.  These tests represent the maximum possible efficiency that the

system can achieve.  Operational efficiency is the actual efficiency after the system has been installed.  It is typically

less than the rated efficiency, due to individual application factors including water hardness, water usage, and other

contaminants that reduce a softener's capacity.

Содержание EP 7130

Страница 1: ...installing operating or maintaining your water softener call our toll free number 1 800 693 1138 Monday Friday 7 AM 6 PM CST in Canada please call 1 866 725 9662 or visit www ecopurewaterproducts com...

Страница 2: ...one call away SIMPLY DIAL 1 800 693 1138 Monday Friday 7 AM 6 PM CST for assistance This water softener is manufactured by Ecodyne Water Systems LLC 1890 Woodlane Drive Woodbury MN 55125 General Provi...

Страница 3: ...treatment if water supply contains clear water iron exceeding 5 ppm Canada working pressure limits 1 4 7 0 kg cm2 These systems conform to NSF ANSI 44 for the specific performance claims as verified a...

Страница 4: ...W Output Voltage 24 VAC Output Current 400 mA Do not use this system to treat water that is microbiologically unsafe or of unknown quality without adequate dis infection upstream or downstream of the...

Страница 5: ...d of time the particles settle to the bottom of the container Generally these irons are removed from water by filtra tion Chlorination is also recommended for bacterial iron Colloidal and inorganicall...

Страница 6: ...ondition all water in the home install the water softener close to the water supply inlet and upstream of all other plumbing connections except outside water pipes Outside faucets should remain on har...

Страница 7: ...e bypass system not included can be purchased and assembled as shown in Figure 8 Bypass valves allow you to turn off water to the softener for mainte nance if needed but still have water in house pipe...

Страница 8: ...or Drain Overflow Drain Elbow Salt Storage Tank Overflow Hose Secure Valve Drain Hose in place over Floor Drain NOTE Water Softener shown with Top Cover removed Installation Instructions TYPICAL INSTA...

Страница 9: ...n as shown in Figures 11 12 IMPORTANT Be sure the clips snap firmly into place so the single bypass valve will not pull out TURN OFF WATER SUPPLY 1 Close the main water supply valve located near the w...

Страница 10: ...nt no higher than the drain fitting on the salt storage tank This is a gravity drain If the tank overfills with water the excess water flows to the drain point Cut the drain line to the desired length...

Страница 11: ...used to make the unit will not infect or contaminate your water supply and will not cause bacteria to form or grow However during shipping storage installation and operation bacteria could get into th...

Страница 12: ...ck Be sure AM or PM is correct NOTE Press buttons and quickly release to slowly advance the display Hold the buttons down for fast advance FIG 17 SET WATER HARDNESS NUMBER 1 Press the SELECT MENU butt...

Страница 13: ...l each time salt is added to the water softener To set this monitor system 1 Slide open the salt lid and level the salt in the stor age tank 2 The salt level decal on the brinewell inside the tank has...

Страница 14: ...this happens you may want to initiate an immediate regeneration as follows 1 Press and hold the RECHARGE button until the words RECHARGE NOW flash in the display The softener enters the fill cycle of...

Страница 15: ...ay FIG 25 Displayed when efficiency is set to ON Efficiency Icon Your EcoPure Water Softener has a High Efficiency feature with an ON or OFF setting This softener setting is shipped in the OFF posi ti...

Страница 16: ...ult If the storage tank is full of salt it is difficult to tell if you have a salt bridge A bridge may be underneath loose salt Take a broom handle or like tool and hold it next to the water softener...

Страница 17: ...n the salt lid and remove the softener s top cover Take off both drain hoses if they will inter fere with moving the softener into position over the drain 5 Carefully remove the large holding clips at...

Страница 18: ...Contact a licensed plumber 6 Brine float dirty or broken Clean or replace Brine Valve Float Assembly 7 Leak between valve and resin tank Replace o rings between resin tank and valve Water hard some t...

Страница 19: ...he sensor from the valve outlet port Pass a small magnet back and forth in front of the sensor If you get a read ing in the display with the magnet unhook the in and out plumbing and check the turbine...

Страница 20: ...ow plug brine tub ing or brine valve riser pipe 2 After observing fill press the RECHARGE button to move the softener into brining A slow flow of water to the drain will begin Verify brine draw from t...

Страница 21: ...21 Notes...

Страница 22: ...2 Softener Exploded View Models EP 7130 EP 7140 8 7 6 5 1 2 18 3 4 5 6 7 8 9 11 Valve Assembly See Pages 24 27 for parts 29 10 12 13 14 31 17 19 15 20 22 21 23 24 25 26 27 28 16 30 70 or 121 72 or 123...

Страница 23: ...uction Decal 20 7155115 Brinewell Cover 21 7137824 Brinewell 7331672 Brinewell Mounting Hardware Kit includes Key Nos 22 24 22 Wing Nut 1 4 20 23 Spacer Brinewell 24 Screw 1 4 20 x 1 25 7311169 Repl B...

Страница 24: ...24 Valve Exploded View 51 50 52 53 55 56 59 58 57 60 61 66 67 62 63 64 68 69 70 71 72 73 74 75 65 76 77 79 78 80 81 82 Wear Strip Seal Cross section View 83 84 85 86 87 88 89 90 54...

Страница 25: ...73 Turbine Support Shaft 74 Turbine 75 7082053 Valve Body 76 7081201 Retainer Nozzle Venturi 77 7170319 O Ring 1 4 x 3 8 2 req 78 1202600 Nut Ferrule 7187065 Nozzle Venturi Assembly incl Key Nos 79 8...

Страница 26: ...el EP 7140 wear strip seal cross section view 100 101 102 103 104 105 106 107 108 109 110 111 112 117 118 113 140 114 115 119 120 121 122 123 124 125 127 126 116 128 129 131 130 132 133 134 135 136 13...

Страница 27: ...97 O Ring 1 1 16 x 1 5 16 pack of 4 Key No Part No Description 7290931 Turbine Support Assembly including 2 O Rings See Key No 123 1 ea of Key Nos 124 125 124 Turbine Support Shaft 125 Turbine 126 730...

Отзывы: