Eco Pacific AussiVent Скачать руководство пользователя страница 2

P a g e

 | 

 

Version10- March 2017 

Eco Pacific Pty Ltd 

Fresh Filtered Air Heat Recovery Ventilator (HRV) 

1.  INTRODUCTION 

The purpose of this guide is to give the installer and service / maintenance personnel a 
quick reference to general information they must know when installing the ECO PACIFIC 
HRV. 

This publication is designed to help the installer.  The guide consists of: 

 

Overview of HRV; 

 

The dealer / 

contractor’s responsibilities; 

 

Installation procedures, and 

 

Warranty details. 

1.1  OVERVIEW OF OUR HRV 

This Eco Pacific Heat Recovery Ventilator innovation substantially improves the quality of 
indoor air, which is increasingly becoming an issue in densely populated and polluted cities 
of India, China, Brazil, Thailand, South Korea, Hong Kong, Malaysia, Vietnam, and many 
other fast developing countries.

 

The HRV extracts the contaminated air inside rooms and introduces outside fresh air to the 
rooms at around the same temperature as the air inside the rooms.  This enhances the 
rooms air quality and reduces the build up of gases such as CO

2

 and unpleasant smells, to 

a level that promotes Personal Well Being.   

The HRV system employs 

energy transfer

 between outgoing and incoming air, 

utilising a 

counter flow Heat Exchanger made of anti-rusting marine grade aluminium alloy, 

and does 

not make use of or replace a traditional air conditioning system.   

The heat exchanger transfers the heat (in winter) or the coolness (in summer) of the 
expelled indoor air to the incoming fresh air, due to temperature difference.  With an energy 
recovery effectiveness of up to 85%, the HRV delivers fresh filtered air at near room 
temperatures in all seasons irrespective of outdoor temperatures.  The HRV operation 
assumes that the indoor space is air-conditioned by an existing heating or cooling device, 
which usually only recycles the same indoor air within closed doors and windows.  There is 
no active heating or cooling device fitted in this HRV, but rather a passive Heat Exchanger 
that exchanges sensible heat energy between the incoming and outgoing air streams.  The 
standard HRV operates through a normal 240 V, 10 Amp switch, like a normal ceiling fan.

 

The incoming outdoor air passes through an externally mounted filter box.  The filter box is 
connected through a duct to the HRV mounted either on a wall, in a roof cavity, or on the 
roof.  

Optional:

 The HRV can also be operated by an Optional Wall Controller fitted with sensors 

for either CO

2

 levels of the indoor air, any motions surrounding the wall controller, or 

blockage of the outdoor air filter.  If the CO

2

 of the room reaches harmful levels and the 

ventilator is in auto-off mode, the sensor will automatically activate the ventilator to provide 
fresh filtered air at near room temperature.  If the filter is blocked, the LED on the On-Off 
switch or on the Wall Controller will turn Red to indicate that the filter needs to be cleaned. 
A house fitted with this HRV will not require open doors or windows, and will introduce fresh 
filtered atmospheric air in the living space at near room temperatures, and assist in keeping 
the house clean and hygienic, so as to enhance a 

Healthy

 

Well Being effect

 in the house.

 

 

 

Содержание AussiVent

Страница 1: ...ions Fresh Filtered Air Ventilators with Efficient Heat Cool Recovery from Indoor Air Models AussiVent EcoVent FreshVent Please read these instructions prior to installation Manufactured by Eco Pacifi...

Страница 2: ...e to temperature difference With an energy recovery effectiveness of up to 85 the HRV delivers fresh filtered air at near room temperatures in all seasons irrespective of outdoor temperatures The HRV...

Страница 3: ...mance and pressure drop Report ref 30S 15 0158 TRP 392476 1 2016 1 3 MODELS AND THEIR DISTINCTIONS There are three models which all utilise a common thermal transfer process The fresh air ventilator i...

Страница 4: ...le namely FV80 and FV120 Illustration 1 Physical appearance of the three models with their dedicated controls 1 4 FILTER BOX The Filter Box is the same for all the models The filter cassette can be cu...

Страница 5: ...FLOWS AV80 EV80 and FV80 provide air flows of 80 l s at 100 Pa external static pressure ESP AV120 EV120 and FV120 provide air flows of 120 l s at 100 Pa ESP Note the Filter Sensor is fitted to the sta...

Страница 6: ...y docket with photo evidence attached and be sent to the local agent dealer The damage should be claimed within three days from inspection The manufacturer supplying the HRV relies on the dealer contr...

Страница 7: ...lated Flexi solid ducts are recommended for the Return Air from indoor to the unit Inlet outlet collar sizes for ducting AussiVent and EcoVent models AV80 AV120 EV80 and EV120 are fitted with 6 inch c...

Страница 8: ...Eco Pacific Pty Ltd Use the M5 bolts 2 each side on the wall brackets Put the HRV on the bracket slide it through and fasten it on to the brackets using two M5 bolts each side threading from the botto...

Страница 9: ...and insects The indoor air inlet should also be fitted with a wire mesh filter inside the grille to protect the heat exchanger from dirt scaling and insects and should be cleaned monthly 3 4 SERVICE...

Страница 10: ...aggravates the ripening process occasionally culminating with rotting of the Produce The FreshVent HRV can remove the ethylene and bring fresh filtered air into the cold room to slow down the ripenin...

Страница 11: ...ir The drain pipe should have gravity fall of at least one inch for every 3 meter length of the drain pipe to the nearest down pipe to the ground Comply with local authorities in regards to drain disc...

Страница 12: ...P a g e 12 Version10 March 2017 Eco Pacific Pty Ltd Illustration 8 Wiring diagram for AussiVent and FreshVent models with AV fans...

Страница 13: ...air tight 9 Check the wall controller is mounted firmly on the wall with clear passage to the power cord and tele connector without interfering with its surrounding Make sure the wall controller s vic...

Страница 14: ...P a g e 14 Version10 March 2017 Eco Pacific Pty Ltd Illustration 9 wiring diagram for EcoVent with AV fans...

Страница 15: ...is free to allow air flow Check outdoor air inlet in the filter Clean the filter Check fan motor operation 3 HRV is running noisy Check the fan wheel is not touching the cabinet if yes call the servic...

Страница 16: ...ower from the power outlet To access a motor remove the two base screws and the two lid screws of that motor end of casing Lift the side panels slightly above the base and pull out this end panel gent...

Страница 17: ...on10 March 2017 Eco Pacific Pty Ltd Illustration 12 Filter side power and wall controller connections for motor and the H X Illustration 13 Base screws 2 at each end to separate the side panels to ser...

Страница 18: ...ed by a faulty installation or maintenance not in accordance with the recommended ECO PACIFIC maintenance schedule Eco Pacific Pty Ltd reserves the right to void the Warranty where the agreed payment...

Отзывы: