When the temperature of the pool water drops (typically wh en it is too c old to s wim), the 

Winter 

Mode 

Switch should be placed in the ON position. The 

Winter Mode 

Indicator will then be ON. 

 

Winter Mode 

setting has two effects: 

1. It alters the setting of the 

Low Salinity Indicator 

and/or 

Cut-Out

2. It reduces the Cell Output by approximately 15%. 

 

The  Unit will now  respond  to a cold pool environm  ent. 

Winter Mode 

should not be used in the 

swimming season as it reduces t he 

Cell Output

, leading to less sanitizer, a nd it alters the setting of 

the  

Low  Salinity  Indicator  

and/or  

Cut-Out

,  which could lead  to prem 

ature ‘Cell’ failure. It is 

recommended to turn off and stop using the ECO-matic at temperatures below 10°C (50F). 

Gas Sensor 

 

The smallest of the three leads wh ich connect to the ‘Cell’ head is the 

Gas Sensor

. Whenever the 

head of the Gas Sensor bolt loses contact with the wa ter (due to gas or a ir pocket in ‘Ce ll’, or scale 
build-up on sensor bolt head), your ECO-matic will 

Cut-Out

 

Shocking the Pool 

 

Periodically, if the pool is heavil y used, to reduce combined c hlorine (chloramines) or for a biological 
“accident” follow your local authority regulations and use Sodium Hypochlorite (Liquid Chlorine) as an 
additional source of chlorine. 

 

Maintenance of your ECO-matic 

 

 

The Power Supply 

 

The power supply should requir e very littl e (if any ) maintenance – exce pt maybe for occasiona l 
replacement  of blown fuses. However, damage to 

certain components may result from improper 

maintenance  of the ‘ Cell’  (see below ). Always ensure that the power 

supply is loc ated in a wel l 

ventilated area free of corrosive fumes from any acid or chemical containers in the vicinity. 

 

Important Note: The two most important maintenance requirements for your ECO-matic are: 
1. Cleaning the ‘Cell’ and 
2. Maintaining sufficient salt level in the pool. 

 

 

The ‘Cell’ 

 

Maintenance  of the ‘Cell’  is quite simple, but very importan t. ECO-matic ‘Ce lls’ are comprised of 
expensive materials and even with proper care and 

maintenance the delicate coating on the ‘Cell’ 

anode will eventually wear away and the ‘Cell’ will ‘die’ and will no longer be able to produce sufficient 
sanitizer for the pool. Proper care (and cleaning) will ensure the maximum life for the ‘Cell’. Operating 
your ‘Cell’ on lower-than-recommended salt levels will shorten ‘Cell’ life and void ‘Cell’ warranties. 

 

Cell Life 

 

The life expectancy of ECO-mati c ‘Cells’ may vary c onsiderably from one installation to the next, due 
to   variations in daily operating time, wate 

r quality and composition, and system and ‘Cell’ 

maintenance. 
Please ensure that when it is time to replace your ‘Cell’, you use only ECO-matic replacement ‘Ce lls. 

Содержание MEMS36USA

Страница 1: ...ppm of free available chlorine must be maintained READ THE LABEL AND OPERATING MANUAL BEFORE USING KEEP OUT OF REACH OF CHILDREN REGISTRATION NO 30295 PEST CONTROL PRODUCTS ACT WARNING operating the...

Страница 2: ...ATION NUMBER 30299 PEST CONTROL PRODUCTS ACT This cell must only be used on this model of chlorine generating device Do not use this device with bromide products Read the Label the Installation Manual...

Страница 3: ...3 INSTALLATION OPERATION INSTRUCTIONS For Commercial Model ECO matic MEMS36USA Automatic Chlorine Generator For Davey Water Products Pty Ltd Australia P N401730...

Страница 4: ...ow Salinity Indicator and Cut Out 21 Installing the Salt Pro Annode 9 Winter Mode 21 Installing the POWER SUPPLY 10 Gas Sensor 21 Connecting the POWER SUPPLY to line voltage 10 Shocking the Pool 22 Ha...

Страница 5: ...when installing ECO matic MEMS36USA Automatic Chlorine Generator 10 NOTE For outdoor pools chlorine residuals can be protected from destruction by sun light by addition of stabilizer cyanuric acid 11...

Страница 6: ...rovide the sanitizer necessary to maintain your pool spa water by using and recyc ling a natural product sa lt Your ECO matic will do exactly the same thing as pool chlorine would do HOCl the same eff...

Страница 7: ...tPro should be ins talled in line and will serve as a sacrific ial component Provided with a bonding lu g and an air release valve Housed in a 5cm 2 slip tee with clear PVC for visual inspection Flow...

Страница 8: ...derations regarding Cell location When correctly installed the Cell will produce sanitiz er only when water is flowing through it and obviously the sanitizer is carried in the water to wherever the wa...

Страница 9: ...from the Cell head The Inlet and outlet pipes must be pointing vertically DOWN to form an inverted U c onfiguration with the Cell Housing The vertical inlet and outlet PVC piping must be a minimum of...

Страница 10: ...ttings for easy connection of PVC to copper pipes Back up Sanitation In the event of a system failure or during periods of extreme bather loads and or very hot weather or due to local authority r egul...

Страница 11: ...the electrolyt ic cell Insta ll one SaltPro per each body of water The anode itself shall have a permanently a ttached bonding lug which shall be connected to the main bonding loop with a 8 bonding wi...

Страница 12: ...12 offs on back of power supply provide ventilation for wall mounted units...

Страница 13: ...en to Ground Simply put the power supply cord wires should be connected to the same terminals as the filter pump to insure that the power supply receives the same voltage as the filter pump and is swi...

Страница 14: ...sure that all internal wiring is clear of the side and bottom panels to allow proper seating of the front panel Insert sides of front panel into the slots at each side slide the front panel UP so its...

Страница 15: ...15...

Страница 16: ...16 Electrical Connection...

Страница 17: ...ly from each bag into the pool water DO NOT load all the salt into one area but rather move along the pool while pouring to distribute the salt evenly During the time the salt is dissolving do not bac...

Страница 18: ...nd controlled as two separate factors Sanitizer The amount of sanitizer required for your pool varies from time to time and depends upon a number of variables including the number of swimmers in the p...

Страница 19: ...r decreases and in time as the Cell nears the end of its life Note Your Test Kit is your ONLY INDICATOR of whether your ECO matic is producing sufficient too little or too much sanitizer for your pool...

Страница 20: ...r pump ON ECO matic also gets power ECO matic power switch can then be left ON and filter power control will also control the ECO matic 2 The unit will enter a START UP PHASE which will repeat itself...

Страница 21: ...air at Stand By on Cell check pump pipes for damage leaks 2 Gas Sensor lead not connected to Cell 3 System is wired incorrectly Approx Green Green System operating normally 90 100 Approx Green Red 1 C...

Страница 22: ...wn Flow Indicator If there is a problem with water fl ow or gas is detected in the Cell Housing the Flow indicator will be ON When this occurs the pump or pipes should be inspected for damage and the...

Страница 23: ...ll turn back ON after the rain has been mi xed into the water unless the salt lev el has been reduced by dilution overflow 2 Scaled Cell a scaled Ce ll will not dra w as much electrical current as a c...

Страница 24: ...tional source of chlorine Maintenance of your ECO matic The Power Supply The power supply should requir e very littl e if any maintenance exce pt maybe for occasiona l replacement of blown fuses Howev...

Страница 25: ...eaning There should be no need to disconnec t the Cell from it s leads for normal Cell cleaning However it may be necessary at some time to disc onnect the cell Cell replacem ent warranty or servic e...

Страница 26: ...re us ed for some time before becoming ineffective saves having to make the solution eac h time Avoid getting the weak acid solution on skin or in your eyes If you accidentally do so wa sh off immedi...

Страница 27: ...where allowed by local authority regulations i Measure the stabilizer level using an appropriate test kit It should be between 15 and25ppm ii If the pool has neve r had stab ilizer added then approx 2...

Страница 28: ...s acceptable ii The use of quaternary ammonium compounds Quats as an algaecide can promote turbidity cloudiness This is caused by the very high chlorine levels in the cell reacting with the Quats comp...

Страница 29: ...se the manufactu rer will provide f ull replacement of the part including labor charges if required Warrant y does not include onsite labor or shipping During the Warranty Period any defective product...

Страница 30: ...29 ACTUAL SIZE TEMPLATE SCREW POSITION TEMPLATE 2 5 8 Use this template for mounting power supply See page 10 for details Screw Position Template...

Страница 31: ...30...

Отзывы: