STEP 1:
Mount the Control/Alarm Panel to the battery case
using the four mounting screws provided. Battery
case has four mounting holes predrilled for easy
installation of control panel.
For best results, use a Group 24, marine battery.
Battery dimensions should not exceed : 9” high
(including post) x 12” long x 6-1/2” wide.
YOUR BATTERY BACKUP SUMP PUMP SYSTEM IS READY.
STEP 2:
Insert marine battery into battery case. Attach
the RED and BLACK wires from the back of the
control/alarm panel to each of the battery clamps
provided. Then connect battery clamps to the
battery. RED WIRE to the POSITIVE (+) terminal
and the BLACK WIRE to the NEGATIVE (-)
terminal.
STEP 4:
Turn the alarm switch on the control/alarm panel to the OFF position and plug the 12 volt transformer in a GFCI
outlet. If a GFCI outlet is unavailable, have an electrician install one for you. Once proper power is supplied, turn
the alarm switch to the on position. Then plug the primary sump pump to its power source.
BATTERY & CONTROL/ALARM PANEL ASSEMBLY
STEP 3:
Plug in the designated components to the control/
alarm panel, A battery backup pump, B the float
switch, C and the 12 volt transformer.
Pre-drilled
Mounting Holes
6-1/2”
12”
9”
B Float Switch
Pump Cord A
Power C
STEP 6:
Feed the pump and float switch cords through
the sump pump vent or utility hole and cover the
sump with the sump cover.
Power
Cord
Float
Switch
Cord