BEFORE FIRST USE

Carefully examine the pump and all parts to ensure no parts 

are damaged. If any part of the pump appears to be dam-

aged, do not use the pump and contact the

 Customer  

Service Team at 1-877-326-3561.
INTENDED USE

This pump is suitable to pump rain water and also can be 

used both for permanent and temporary installation. The 

pump can be placed in a sump pit to pump rain water con-

taining suspended solid particles 3/8 in. for EPC33 & EPC50 

and 3/16 in. for EPP33 & EPP50 or less in diameter.
INSTALLATION REQUIREMENTS

Call an electrician when in doubt. Pump should be connected 

to a separate 15 amp circuit breaker or 15 amp fuse block. 

Note that plugging into existing outlets may cause low volt-

age at the motor. This could cause blown fuses, tripping of 

the motor, overload or burned-out motor.
This pump is provided with an on/off float switch for  

automatic operation. Refer to the Installation instructions 

included with switches andcontrollers for installation.
Care should be taken to prevent the pump from running in a 

dry sump.
Plastic PVC pipe can be installed in the outlet piping. Drain 

hose, galvanized steel or copper pipe may be used if desired. 

All piping must be clean and free of all foreign matter to pre-

vent clogging.
Before installing the pump, clear the sump basin of any 

water, debris, or sediment. 

g the pum

p, clear the sump basin

PRE-INSTALLATION

Pump

Float Assembly

Spare Float 

Assembly 

Parts

PACKAGE CONTENTS

 

 

 

MATERIALS REQUIRED (NOT INCLUDED)

Before using this pump, ensure you have the following items:  

Inlet and discharge piping, Thread sealant tape, Check 

valve, PVC glue and Sump basin

1

 PREPARING THE PUMP

Remove the upper rubber grommet  

(1) from the float assembly (B).

2

  ATTACHING FLOAT ASSEMBLY

Insert the top of the float assembly (B) in 

the switch arm hole. Slide the upper  

rubber grommet (1) over the end of the 

float assembly (B) to hold the float  

assembly in place. Adjust the float 

assembly per the dimensions in step 3.

3

  ADJUSTING THE FLOAT ASSEMBLY

•   Install the bracket (1) to the hole on the column  

  (A). Ensurethe pin on the bracket (1) is inserted in  

  the hole on the column (A).
•   Adjust the lower rubber grommet’s position  

  (control switch ON). The grommet (2) should be  

  between 5.5 in. and 9 in. from the top of the rod.
•   Adjust the upper rubber grommet’s position  

   

(control switch 

   

OFF). The grom 

   

met (3) should be  

   

2.3 in. from the  

   

top of the rod.

ASSEMBLY

1

1

1

2

3

A

B

B

B

3

Содержание EPC33

Страница 1: ...is symbol on your pump or in this manual look for one of the following signal words and be alert to the potential for personal injury Indicates a hazard which if not avoided will result in death or se...

Страница 2: ...th Pumped EPP33 1 3 120 1 4 0 3600 18 Thermoplastic Thermoplastic 8 3 16 EPC33 1 3 120 1 4 0 3600 18 Cast Iron Thermoplastic 8 3 16 EPP50 1 2 120 1 5 2 5000 22 Thermoplastic Nylon 8 3 8 EPC50 1 2 120...

Страница 3: ...piping Drain hose galvanized steel or copper pipe may be used if desired All piping must be clean and free of all foreign matter to pre vent clogging Before installing the pump clear the sump basin o...

Страница 4: ...e surface is clear of debris Never place the pump on clay earth or gravel surfaces It is recommended that the pump be placed on two bricks not included approximately 2 in apart 3 CONNECTING THE PIPE A...

Страница 5: ...clogged with depris Unplug the pump to disconnect the electrical power Unscrew the screws 1 Remove the base Remove any debris from around the impeller 3 Reassemble the pump ADDITIONAL MAINTENANCE GUID...

Страница 6: ...the breaker or replace the fuse If the problem continues contact a plumbing professional 2 The pump will turn on when water level reaches the appropriate depth for your switch type 3 Replug the pump...