background image

Содержание ECO8LDN

Страница 1: ...pful hints on how to use and maintain your dehumidifier properly Just a little preventative care on your part can save you a great deal of time and money over the life of your dehumidifier You ll find many answers to common problems in the chart of troubleshooting tips Review the chart of Troubleshooting Tips before calling your service engineer L P ...

Страница 2: ...ance as unsorted waste or with your domestic household waste Please observe local regulations for disposal Most local authorities have specific collection systems for appliances where disposals are free of charge to the end user When replacing an existing appliance with a new appliance your retailer may take back the old appliance for disposal ...

Страница 3: ...minal which is marked with the letter N or coloured BLACK The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED The GREEN YELLOW is the EARTH and must be connected to the terminal which is marked with the letter E or or coloured GREEN OR GREEN YELLOW Always ensure that the cord grip is positioned and fastened correctly If a I 3A BS 1363 ...

Страница 4: ...ntrol panel and features 4 IDENTIFICATION OF PARTS Identificationof parts 5 OPERATING THE UNIT Positioning the unit using the unit 6 Removingthe collected water 7 CARE AND MAINTENANCE Care and cleaning the dehumidifier 8 Optional Filter Hepa Carbon Filter 9 TROUBLESHOOTING TIPS Troubleshootingtips 10 0 L P ...

Страница 5: ...fire generation u z IuFztiTT O Disconnect the po it unit You should never try to Before cleaning turn off strange sounds s take apart or repair the I the power and unplug the smoke comes fro by yourself unit lei O Do not use the machine near Do not drink or use the I Do not open the unit I flammable gas or combustibles such water drained from air during operation as_ gasoline _benzene _thinner etc...

Страница 6: ...ormation The manufacturer s nameplate is located on the rear panel of the unit and contains electrical and other technical data specific to this unit The dehumidifier must be properly earthed To minimize shock and fire hazards proper earthing is important The power cord is equipped with a three pin plug for protection against shock hazards Your dehumidifier must be used in a properly grounded wall...

Страница 7: ...d plug it back in If error repeats call for service E2 Temperature sensor error Unplug the unit and plug it back in If error repeats call for service P1 Unit is defrosting Adlow the unit time to automatically defrost The error will clear after the unit self defrosts P2 Bucket is full Empty the bucket and replace in the right position the error will reset after a few seconds NOTE When more than one...

Страница 8: ...P P IDENTIFICATION OF PARTS Front Rear Air outlet Carry Handle grille Control panel Air intake filter o Water bucket Continuous drain hose outlet see page 7 Power Cord Pow Fig 3 and plug 0 L P ...

Страница 9: ...e Closing doors windows and other outside openings will improve the efficiency of the dehumidification process 40cm or more 20cm or more 20cm or more 20cm or more 20cm or more Fig 4 Using the unit Select a suitable location making sure you have easy access to an electrical outlet Plug the unit into a 220 240V 50Hz electrical power socket The electrical socket outlet must be fitted with an earth co...

Страница 10: ...hen the bucket is correctly inserted NOTES Be sure to push the bucket gently all the way into the unit Forcing the bucket back into the machine may ___ cause damage to the tank or the unit Fig 6 3 Pour the water out and replace 2 Using continuous drainage If you are leaving the unit for long periods then it may be beneficial to drain the water away continuously This can be done by inserting a pipe...

Страница 11: ... should be checked and cleaned at least every 30 days or more often if necessary To remove the filter Grip the tab on the bottom the filter housing and pull it upward then pull it out and down as shown in Fig 9a Clean the filter with warm soapy water Rinse and let the filter dry before replacing it Do not clean the filter in a dishwasher To replace the filter Insert the air filter into the unit lo...

Страница 12: ...rectly from EcoAir Please contact 020 8459 2458 The HEPAor Carbon Filter is optional but the washable nylon filter must always be used To replace the HEPA or Carbon filter First remove the washable nylon air filter Fig 1 Oa Remove the HEPAfilter from the frame behind the air filter Insert the HEPAor Carbon filter within the lugs around the frame Fig lOc Refit the nylon air filter Remove nylon air ...

Страница 13: ...f air the unit has to dehumidify Room temperature is too low below 5 C 41 F There is a gas heater a fish tank or something giving off water vapour in the room The The air filter is clogged unit makes a loud 1111111 IThe unit is tilted instead of upright as it should be noise when operating IThe floor surface is not level or is unsupported causing Lresonance Frost appears on the 1 j 111111 This is ...

Страница 14: ...commended at voltages indicated on the unit Any attempts made to service or modify the unit will render this WARRANTY VOID The actual product may differ slightly from the illustration This warranty is in addition to and does not affect your statutory rights For further information please contact 020 8459 2458 This product has been manufactured to comply with the EEC Directives 73 23 EEC and 89 336...

Отзывы: