Eco Air ECO10P Скачать руководство пользователя страница 5

 

BEFORE USE

BEFORE USE

BEFORE USE

BEFORE USE

 

 

GENERAL SAFETY

GENERAL SAFETY

GENERAL SAFETY

GENERAL SAFETY    
 

 

ONLY USE IN THE UPRIGHT POSITION ON 

A  FLAT  LEVEL  SURFACE  AND  AT  LEAST 
50cm FROM ANY OBJECTS (Fig 1&4). 

 

DO  NOT  PLACE  OBJECTS  ON  THE  UNIT 

OR RESTRICT AIR INLET/OUTLET (FIG. 2). 

 

CLOSELY  SUPERVISE  ANY  CHILDREN 

AND PETS WHEN UNIT IS IN USE.  

 

THIS  APPLIANCE  IS  NOT  INTENDED  FOR 

USE 

BY 

PERSONS 

(INCLUDING 

CHILDREN)  WITH  REDUCED  PHYSICAL, 
SENSORY  OR  MENTAL  CAPABILITIES,  OR 
LACK 

OF 

EXPERIENCE 

AND 

KNOWLEDGE,  UNLESS  THEY  HAVE  BEEN 
GIVEN  SUPERVISION  OR  INSTRUCTION 
CONCERNING  USE  OF  THE  APPLIANCE 
BY  A  PERSON  RESPONSIBLE  FOR  THEIR 
SAFETY. 

CHILDREN 

SHOULD 

BE 

SUPERVISED  TO  ENSURE  THAT  THEY  DO 
NOT PLAY WITH APPLIANCE. 

 

 
ELECTRICAL SAFETY

ELECTRICAL SAFETY

ELECTRICAL SAFETY

ELECTRICAL SAFETY    
 

 

FOR INDOOR USE ONLY. 

 

 

SWITCH OFF AND UNPLUG WHEN NOT 

IN USE. 

 

 

DO NOT USE IN HUMID OR WET 

ENVIRONMENTS (FIG 3) 

 

 

DO NOT PULL THE UNIT ALONG BY THE 

CORD. 

 

 

IF THE SUPPLY CORD IS DAMAGED, IT 

MUST BE REPLACED BY AN 
ELECTRICIAN OR SIMILARLY QUALIFIED 
PERSON, TO AVOID HAZARD. 

 

 

 

FIG. 1 

 

 
 
 
 
 
 
 
 
 

 

FIG. 2 

 
 
 
 
 
 
 
 
 
 
 
 

 

FIG. 3 

 
 
 
 

 

 

 

-  3  - 

Содержание ECO10P

Страница 1: ...Model information can be found on the CE label Please register your product online at www ecoair org For your future convenience record the model information below ___________________________________...

Страница 2: ...trols and the most economical operation CONTENTS BS Plug Wiring 1 Specification 2 Before Use 3 Product Description 5 Installation 6 Mounting of the Exhaust Pipe 7 Installation of Carbon Filter 8 Opera...

Страница 3: ...nnected to the terminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The G...

Страница 4: ...240V 50Hz Compressor rotary Noise Level 53 dB Refrigerant R410A 370g Fan speed 2 Timer 1 12 hours Working temperature Cooling 18 32 o C Heating 7 25 o C Exhaust pipe 120x1500mm Net Weight 25 5 kgs Gr...

Страница 5: ...SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY CHIL...

Страница 6: ...heat and will reduce the cooling effectiveness Avoid opening doors frequently Keep curtains or blinds closed during the warmest part of the day Keep filters clean Once room has reached the desired co...

Страница 7: ...Air filter 11 Air inlet 12 Water bung 13 Air outlet Accessories 14 Outward adaptor for insertion over hose and into foam strip or into hole in the wall window 15 Round cap for filling the hole in wall...

Страница 8: ...ip into window gaps as shown and slide window across so that foam is held securely This technique may also be used for sash windows Note Take care to maintain protection against intruders 2 Using the...

Страница 9: ...lip exhaust hose to the back of the air conditioner Avoid kinks and bends in the exhaust hose as this will cause expelled moist air to build up causing the unit to overheat and shut down Fig 11 12 sho...

Страница 10: ...the active carbon filter from its plastic bag 4 Attach the active carbon filter to the filter frame 5 Attach the filter fixer to the filter frame the active carbon filter should be hold between the fi...

Страница 11: ...3 Receiver for remote control 14 Low ventilation indicator 15 High ventilation indicator 16 Compressor operation indicator 17 Water Full indicator Turning ON OFF 1 Press ON OFF button the unit will st...

Страница 12: ...s in AUTO mode it will choose the ventilation speed automatically according to the ambient temperature the related indicators will light on at this time the speed switch is invalid Setting timer 1 Pre...

Страница 13: ...emperature The ventilation however keeps working on the set level If the ambient temperature rises above the selected level the cooling will return to work 3 The heating will switch off if the ambient...

Страница 14: ...it when full 2 Position a container a water tray for example underneath the drain hole 3 Remove the drain knob rubber plug from the drain hole and allow the water to drain out 4 When the container is...

Страница 15: ...drain tube Special caution for heating function While using the heating function please note 1 Install the exhaust pipe well in order to exhaust the cool air to outdoor Please refer to the instructio...

Страница 16: ...eaning the filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water no hotter than 40o C Dry thoroughly before...

Страница 17: ...y people in the room Is there something in the room producing lots of heat The machine seems to do nothing Is the filter dusty contaminated Is the air intake or output blocked up Is the room temperatu...

Страница 18: ...10P 204 19 99 Exhaust Accessories Exhaust Hose 1 5m 10P 138 24 99 Tube for continuous drainage 10P 135 6 99 Extension drainage tube 1m 10P 815 4 99 Water Bung 10P 134 6 99 Other Accessories Caster Whe...

Страница 19: ...iffer slightly from the illustration This warranty is in addition to and does not affect your statutory rights For after sales needs please visit www ecoair org service or email technical ecoair org o...

Отзывы: