101
15. Electronic Function
15.1 Abbreviation
T1: Indoor room temperature
T2: Coil temperature of indoor heat exchanger
T3: Coil temperature of condenser
T4: Outdoor ambient temperature
T5: Compressor discharge temperature
Td: Target temperature
15.2 Display function
15.2.1 Icon explanation on indoor display board
(Duct)
15.2.2 Icon explanation on indoor display board
(Compact cassette).
15.2.3 Icon explanation on indoor display board
(slim Cassette).
15.2.4 Icon explanation on indoor display board
(Console).
15.2.5 Icon explanation on indoor display board
(Ceiling Floor)
15.3 Main Protection
15.3.1 Three minutes delay at restart for
compressor
1 minute delay for the 1
st
time stand-up and 3
minutes delay for others.
15.3.2
Temperature
protection
of
compressor top
The unit will stop working when the compressor
top temp. protector cut off, and will restart after
the compressor top temp. protector restart.
15.3.3
Temperature
protection
of
compressor discharge
When the compressor discharge temp. is
getting higher, the running frequency will be
limited as below rules:
---Compressor discharge temp. T5>115
℃
(239°F) for 5s, compressor stops and restarts
up till T5<90
℃
(194°F)
---110<T5<115
℃
(239°F), decrease the
frequency to the lower level every 2 minutes.
---105(221°F)<T5<110
℃
(230°F), keep running
at the current frequency.
----T5<105
℃
(221°F), no limit for frequency.
15.3.4 Fan speed malfunction
When indoor fan speed keeps too low (lower
than 300RPM) for 50s, the indoor fan will shut
OPERATION TIMER DEF./FAN
ALARM
Temporary button
Operation lamp
Timer indicator
Infrared signal receiver
Alarm indicator
PRE-DEF indicator(cooling and heating type)
or fan only indicator(cooling only type)
MANUAL
Display digital tube
Содержание CTBU-09HWFN1-M(C)
Страница 8: ...5 2 2 Part names of Indoor Outdoor units Cassette Units...
Страница 9: ...6 A5 Duct Units A6 Duct Units...
Страница 10: ...7 Console Units...
Страница 11: ...8 Ceiling floor Units...
Страница 12: ...9 HESP DUCT Units...
Страница 21: ...18 2 3 4 7 Outside Water Pump for Optional When Ceiling Installation...
Страница 29: ...26 Console Units 1 6 D ra in p ip e 1 9 5 H a n g in g a rm U n it m m 7 0 0 6 0 0 2 1 0...
Страница 36: ...33 Console Units Ceiling floor Units...
Страница 41: ...38 CFAU 09HRFN1 M C CFAU 12HRFN1 M C MCD 36HRFN1 M C MCD 48HRFN1 M D...
Страница 42: ...39 CTBU 36HWFN1 M C CTBU 48HWFN1 M C...
Страница 43: ...40 MUEU 18HRFN1 M C MUEU 24HRFN1 M C MUE 36HRFN1 M C...
Страница 44: ...41 MUE 48HRFN1 M C MUE 60HRFN1 MW...
Страница 45: ...42 MUE 36HRFN1 M C MUE 48HRFN1 M C...
Страница 46: ...43 MUE 60HRFN1 MW MTIU 09HWFN1 M MTIU 12HWFN1 M MTIU 18HWFN1 M MTIU 24HWFN1 M...
Страница 49: ...46 MOBA30 09HFN1 MT0W MOB30 12HFN1 MT0W...
Страница 50: ...47 MOD30 24HFN1 MT0W MOD01 23HFN1 MT0W...
Страница 51: ...48 MOD30U 36HFN1 M...
Страница 57: ...54 CTBU 09HWFN1 M C Code 0 Code 1 Code 2 Code 3 Code 4...
Страница 58: ...55 CTBU 12HWFN1 M C Code 0 Code 1 Code 2 Code 3 Code 4...
Страница 59: ...56 CTBU 18HWFN1 M C Code 0 Code 1 Code 2 Code 3 Code 4...
Страница 60: ...57 CTBU 24HWFN1 M C Code 0 Code 1 Code 2 Code 3 Code 4...
Страница 61: ...58 CTB 36HWFN1 M C Code 0 Code 1 Code 2 Code 3 Code 4...
Страница 62: ...59 CTB 48HWFN1 M C Code 0 Code 1 Code 2 Code 3 Code 4...
Страница 78: ...75 12 Field Wiring 9K 24K 36K 48K 60K...
Страница 79: ...76...
Страница 129: ...126 P U P V...
Страница 130: ...127 P W P N...
Страница 147: ...144...
Страница 157: ...154 4 Remove the evaporator support board 5 Screw off the fixing screws to remove the evaporator 4 screws 1 screw...
Страница 193: ...190 5 Remove the four fixing screws of the fan motor then remove the motor 5...
Страница 206: ...203 6 Remove the grounding screw 7 Remove the Wires 1 2 3 or L1 L2 S Then remove the electronic control box 7...