Eclipse WX Series Скачать руководство пользователя страница 7

7

Eclipse Winnox WX Series v1 Design Guide No. 111, 9/25/2008

Safety

This section is provided as a guide for the safe operation of  

Winnox burner system. All involved personnel should read this 

section carefully before operating this system. 

Danger:
The Winnox burners, described herein, are designed 

to mix fuel with air and burn the resulting mixture. All 

fuel burning devices are capable of producing fires 

and explosions if improperly applied, installed,  

adjusted, controlled, or maintained. Do not bypass 

any safety feature; fire or explosion could result. 

Never try to light a burner if it shows signs of damage 

or malfunction.

Warning:

The burner might have HOT surfaces. Always wear 

protective clothing when approaching the burner.

Note:

This manual provides information in the use of these  

burners for their specific design purpose. Do not  

deviate from any instructions or application limits  

described herein without written advice from Eclipse. Read 

the entire manual before attempting to start this system. If 

you do not understand any part of the information  

contained in this manual, contact Eclipse before  

continuing.

Only qualified personnel, with good mechanical aptitude and 

experience with combustion equipment, should adjust, maintain, or 

troubleshoot any mechanical or electrical part of this system.

The best safety precaution is an alert and trained operator. Train 

new operators thoroughly and have them demonstrate an  

adequate understanding of the equipment and its operation. A 

regular retraining schedule should be administered to ensure  

operators maintain a high degree of proficiency.

Order replacement parts from Eclipse only. All Eclipse approved, 

customer supplied valves or switches should carry UL, FM, CSA, 

CGA, and/or CE approval, where applicable.

i

NtroDuCtioN

s

afety

C

apabilities

2

o

perator

 t

raiNiNg

r

eplaCemeNt

 p

arts

Содержание WX Series

Страница 1: ...Eclipse Winnox Burners WX Series Version 1 Design Guide 111 9 25 2008...

Страница 2: ...sed or implied We have made every effort to make this manual as accurate and complete as possible Should you find errors or omissions please bring them to our attention so that we may correct them In...

Страница 3: ...f equipment Design Guide No 111 This document Datasheet Series 111 Available for individual WX models Required to complete design and selection Installation Guide No 111 Used with Datasheet to complet...

Страница 4: ...ained personnel are allowed to carry out these instructions or procedures Act with great care and follow the instructions Warning Indicates hazards or unsafe practices which could result in severe per...

Страница 5: ...ies 7 Operator Training 7 Replacement Parts 7 System Design 8 Design 8 Step 1 Burner Option Selection 9 Step 2 Packaged Blower Option Selection 11 Step 3 Control Methodology 12 Step 4 Ignition System...

Страница 6: ...ner package includes a combustion air blower and an air gas ratio regulator to fire over a wide gas turndown range at a controlled ratio The burner is designed for low NO X and CO emmisions efficient...

Страница 7: ...esign purpose Do not deviate from any instructions or application limits described herein without written advice from Eclipse Read the entire manual before attempting to start this system If you do no...

Страница 8: ...on Flame Supervision Air Flow Switch Blower Option Selection Including 2 Power Supply Frequency Pressure and Flow Blower Motor Type Blower Inlet Motor Orientation Control Methodology Including 3 Burne...

Страница 9: ...3 each 1000 feet 300 meters above sea level Combustion Air Supply Combustion air should be fresh 20 9 O2 and clean without particles or corrosives Combustion Air Temperature Changes in air supply temp...

Страница 10: ...f rotation certain applications may require control motors with a limit switch or switches if the burner capacity is to be limited to fit an application the chamber is to be fired with positive or neg...

Страница 11: ...may vary Power Supply Frequency Select the 50Hz or 60Hz option The 50Hz blower motors have IEC frames and are CE marked The 60Hz motors have NEMA frames Pressure Flow Nominal and derated options are a...

Страница 12: ...ers Figure 3 5 Basic Control Loop The control motor modulates the integral air butterfly valve BV which controls the combustion air flow Air pressure in the burner body sends an impulse down the loadi...

Страница 13: ...me it takes for a burner to ignite These requirements vary from one location to another check your local codes and comply to the strictest codes applicable The time it takes for a burner to ignite dep...

Страница 14: ...monitoring control processes the signal from the flame rod or UV scanner and controls the start up sequence and the main gas shut off valve sequence Eclipse recommends the use of flame monitoring con...

Страница 15: ...ement device Eclipse recommendations can be found in the appropriate Winnox datasheet series 111 Valve Train Size Fuel pressure supplied to the ratio regulator inlet must be within the range specified...

Страница 16: ...Do not operate Winnox burners with gas inlet pressure less than the minimum listed on the Winnox datasheet Lower gas inlet pressures may cause the ratio regulator to remain fully open at lower inputs...

Страница 17: ...imeter mm inch in 3 94 x 10 2 MJ m normal BTU ft standard 2 491 x 10 2 Metric to English From To Multiply By kiloPascals kPa millibar mbar 10 meter m millimeter mm 1000 millibar mbar kiloPascals kPa 0...

Страница 18: ...Offered By Power Equipment Company 2011 Williamsburg Road Richmond Virginia 23231 Phone 804 236 3800 Fax 804 236 3882 www peconet com...

Отзывы: