Eclipse ThermJet TJ0015 - 2000 Скачать руководство пользователя страница 2

2

Copyright

Copyright 2007 by Eclipse, inc. All rights reserved
worldwide. This publication is protected by federal
regulation and shall not be copied, distributed,
transmitted, transcribed or translated into any human or
computer language, in any form or by any means, to any
third parties, without the express written consent of
Eclipse, inc.

Disclaimer Notice

In accordance with the manufacturer’s policy of continual
product improvement, the product presented in this
brochure is subject to change without notice or obligation.

The material in this manual is believed adequate for the
intended use of the product. If the product is used for
purposes other than those specified herein, confirmation
of validity and suitability must be obtained. Eclipse
warrants that the product itself does not infringe upon any
United States patents. No further warranty is expressed or
implied.

Liability & Warranty

We have made every effort to make this manual as
accurate and complete as possible. Should you find errors
or omissions, please bring them to our attention so that we
may correct them. In this way we hope to improve our
product documentation for the benefit of our customers.
Please send your corrections and comments to our
Technical Documentation Specialist.

It must be understood that Eclipse’s liability for its product,
whether due to breach of warranty, negligence, strict
liability, or otherwise is limited to the furnishing of
replacement parts and Eclipse will not be liable for any
other injury, loss, damage or expenses, whether direct or
consequential, including but not limited to loss of use,

income, or damage to material arising in connection with
the sale, installation, use of, inability to use, or the repair
or replacement of Eclipse’s products. 

Any operation expressly prohibited in this manual, any

adjustment, or assembly procedures not recommended or 
authorized in these instructions shall void the warranty. 

Document Conventions

There are several special symbols in this document. You
must know their meaning and importance.

The explanation of these symbols follows below. Please
read it thoroughly.

How To Get Help

If you need help, contact your local Eclipse
representative. You can also contact Eclipse at:

1665 Elmwood Rd.
Rockford, Illinois 61103 U.S.A.
Phone: 815-877-3031
Fax: 815-877-3336
http://www.eclipsenet.com

Please have the information on the product label available
when contacting the factory so we may better serve you.

Product Name
Item #
S/N
DD MMM YYYY

www.eclipsenet.com

This is the safety alert symbol. It is used to alert you to potential personal
injurt hazards. Obey all safety messages that follow this symbol to avoid
possible injury or death.

Indicates a hazardous situation which, if not avoided, will result in death
or serious injury.

Indicates a hazardous situation which, if not avoided, could result in
death or serious injury.

Indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.

Is used to address practices not related to personal injury.

Indicates an important part of text. Read thoroughly.

NOTE

NOTICE

CAUTION

WARNING

Содержание ThermJet TJ0015 - 2000

Страница 1: ...Eclipse ThermJet Burners Model TJ0015 2000 Version 2 Technical Information Edition 2 14...

Страница 2: ...and Eclipse will not be liable for any other injury loss damage or expenses whether direct or consequential including but not limited to loss of use income or damage to material arising in connection...

Страница 3: ...apabilities 5 Operator Training 5 Replacement Parts 5 3 System Design 6 Design 6 Step 1 Burner Model Selection 6 Step 2 Control Methodology 7 Step 3 Ignition System 12 Step 4 Flame Monitoring Control...

Страница 4: ...er Audience This manual has been written for people who are already familiar with all aspects of a nozzle mix burner and its add on components also referred to as the burner system These aspects are D...

Страница 5: ...by sanding sawing grinding cutting and other construction activities could release crystalline silica Crystalline silica is known to cause cancer and health risks from the exposure to these chemicals...

Страница 6: ...ased on requirements for temperature uniformity circulation chamber size air pressure and overall operating costs Flame velocity information is available in Datasheets 205 1 through 205 13 Fuel Type T...

Страница 7: ...on page 9 2 High low control a High low air gas control pulse firing on page 10 b High low gas with fixed air control Can also be used for pulse firing on page 11 NOTE Use of a ratio regulator in a f...

Страница 8: ...lator can be biased to give excess air at low fire NOTE Do not use an adjustable limiting orifice ALO as the high fire gas limiting valve ALO s require too much pressure drop for use in a proportional...

Страница 9: ...r eliminating the ratio regulator will adversely affect the ignition reliability at inputs greater than 40 of maximum Figure 3 2 Modulating Gas with Fixed Air Control Optional IF flame monitoring syst...

Страница 10: ...the solenoid valve Low fire gas passes through the butterfly valve b High fire A control input opens the solenoid valve Figure 3 3 High Low Air Gas Control Pulse Firing NC Automatic shut off by zone...

Страница 11: ...en solenoid valve NOTE Use of a ratio regulator in a fixed air system is optional on a single burner system only However eliminating the ratio regulator will adversely affect the ignition reliability...

Страница 12: ...ollow the control circuits described in the previous section Control Methodology to obtain reliable ignition Local safety and insurance require limits on the maximum trial for ignition time These time...

Страница 13: ...lve in the bypass line plus the automatic gas shut off valve either at each burner or each zone are opened If a flame is established the bypass solenoid valve closes at the end of the trial for igniti...

Страница 14: ...is detected may prevent establishment of flame particularly when using UV scanners The flame monitoring control must maintain the spark for a fixed time interval that is long enough for ignition DO N...

Страница 15: ...ber and motor horsepower hp With the output pressure and the specific flow you can find the blower catalog number and the motor hp in Bulletin 610 4 Eclipse recommends that you select a totally enclos...

Страница 16: ...can help you design and obtain a main gas shut off valve train that complies with the current safety standards The shut off valve train must comply with all the local safety standards set by the autho...

Страница 17: ...illimeter mm inch in 3 94 x 10 2 MJ Nm Btu ft standard 26 86 From To Multiply By kiloPascals kPa millibar mbar 10 meter m millimeter mm 1000 millibar mbar kiloPascals kPa 0 1 millimeter mm meter m 0 0...

Страница 18: ...ne This impulse line is connected between the top of the ratio regulator and the burner body Main Gas Shut Off Valve Train Eclipse strongly endorses NFPA as a minimum 790 791 Pilot Gas Valve Train Ecl...

Страница 19: ...anual reset version requires pushing a button to transfer the contacts when the pressure set point is satisfied 840 Pressure Gauge A device to indicate pressure 940 Check Valve A check valve permits f...

Страница 20: ...Eclipse Inc All Rights Reserved...