Eclipse TFB, V2, Design Guide 310, 11/14/2014

Example Blower Calculation

"A batch furnace has been designed and requires a heat
input of 2,900,000 Btu/h. It has been decided to provide
the required heat input with four burners operating on
natural gas using 15% excess air."

Calculation example:

a.Decide which TFB burner model is appropriate:

-  Select 4 Model TFB075 TFB burners based on the 

required heat input of 725,000 Btu/hr for each 

burner.

b.Calculate required gas flow:

- Gas flow of 2,894 ft

3

/hr is required

c.Calculate required stoichometric air flow:

- Stoichiometric air flow of 27,235 scfh required

d.Calculate final blower air flow requirement based

on the desired amount of excess air:

-  For this example, final blower air flow requirement 

is 31,320 scfh at 15% excess air.

NOTE:

 It is common practice to add an additional 

10% to the final blower air flow requirement as a 

safety margin.

3. Find the blower model number and motor horsepower

(hp). With the output pressure and the specific flow,
you can find the blower catalog number and the motor
hp in Bulletin / Info Guide 610.

4. Eclipse Combustion recommends that you select a

Totally Enclosed Fan Cooled (TEFC) motor.

5. Select the other parameters:

• inlet filter or inlet grille
• inlet size (frame size)
• voltage, number of phases, frequency
• blower outlet location, and rotation direction 

Clockwise (CW) or Counter Clockwise (CCW)

NOTE:

 The use of an inlet air filter is strongly 

recommended. The system will perform longer and the 
settings will be more stable.

NOTE:

 When selecting a 60 Hz Blower for use on 50 Hz, 

a pressure and capacity calculation is required. See 
Eclipse Combustion Engineering Guide (EFE 825)

The total selection information you should now have:

• blower model number
• motor hp
• motor enclosure (TEFC)
• voltage, number of phases, frequency
• rotation direction (CW or CCW)

Air Pressure Switch

The air pressure switch gives a signal to the monitoring
system when there is not enough air pressure from the
blower. You can find more information on pressure
switches in:

• Blower Bulletin 610

 Eclipse Combustion supports NFPA regulations,

which require the use of an air pressure switch in
conjunction with other safety components, as a
minimum standard for main gas safety shut-off
systems.

Step 6: Main Gas Shut-Off Valve Train

Eclipse can help you design and obtain a main gas shut-
off valve train that complies with the current safety
standards. The shut-off valve train must comply with all
the local safety standards set by the authorities that have
jurisdiction. For details, please contact Eclipse.

NOTE:

 Eclipse supports NFPA regulations (two shut-off

valves) as a minimum standard for main gas safety shut-
off systems.

Step 7: Process Temperature Control 

System

The process temperature control system is used to control
and monitor the temperature of the system. There is a
wide variety of control and measuring equipment
available. For details, please contact Eclipse.

Table 3.5 Fuel Gas Heating Values

Fuel Gas

Stoichiometric* 

Air/Gas Ratio

 (ft

3

air

 / ft

3

gas

)

Gross Heating 

Value q (BTU/ft

3

)

Natural Gas
(Birmingham, AL)

9.41

1,002

Propane

23.82

2,572

Butane

30.47

3,225

*Stoichiometric: No excess air. The precise amount of air and 
gas are present for complete combustion.

Q (total heat input) of 

2,900,000 BTU/hr

= 725,000 BTU/hr/burner

4 burners

V

gas

=

Q

=

2,900,000 BTU/hr

= 2,894 ft

3

/hr

q

1,002 BTU/ft

3

V

air-Stoichiometric

=



air/gas ratio

x V

gas

= 9.41 x 2,894 ft

3

/hr

= 27,235 ft

3

/hr

V

air

=

(1 + excess air 

%)

x V

air-Stoichiometric

= (1 + 0.15) x 27,235 ft

3

/hr = 31,320 ft

3

/hr

WARNING

Содержание TFB030

Страница 1: ...Eclipse Tube Firing Burners Models TFB030 TFB075 TFB200 Version 2 TFB030 075 TFB200 11 14 2014 Design Guide 310...

Страница 2: ...and Eclipse will not be liable for any other injury loss damage or expenses whether direct or consequential including but not limited to loss of use income or damage to material arising in connection...

Страница 3: ...ment Parts 5 3 System Design 6 Design 6 Step 1 Burner Selection 6 Step 2 Control Methodology 10 Step 3 Ignition System 11 Step 4 Flame Monitoring Control System 11 Step 5 Combustion Air System Blower...

Страница 4: ...commended recuperators for the TFB are the Eclipse Bayonet Data 317 and the Bayonet Ultra Spec 318 Figure 1 1 TFB Burner Audience This manual has been written for people who are already familiar with...

Страница 5: ...by sanding sawing grinding cutting and other construction activities could release crystalline silica Crystalline silica is known to cause cancer and health risks from the exposure to these chemicals...

Страница 6: ...et TFB030 310 2 Datasheet TFB075 310 3 Datasheet TFB200 Fuel Type The usable fuel types are Natural Gas Propane Butane For other fuels contact Eclipse with an accurate breakdown of the fuel contents A...

Страница 7: ...rner Input Calculate the gross burner input BTU hr with this formula Gross Burner Input Required Heat Release Efficiency Compare the Gross Burner Input Compare the gross burner input with the maximum...

Страница 8: ...he net heat release to the tank is derived from heat balance calculations These calculations are based on the heat up and steady state requirements of the process and take into account surface losses...

Страница 9: ...7 x 12 444 8 625 x 3 142 x 44 12 032 3 sq in BTU hr sq in Net heat release to tank sq in surface area 1 000 000 12 032 3 83 1 BTU sq in hr NOTE If the medium to be heated in the above example was cook...

Страница 10: ...choose depends on the type of process that you want to control Control Methods There are two main methods to control the input of a TFB system 1 Modulating control A burner system with modulating cont...

Страница 11: ...n the time limit Under these circumstances you must consider the following options start at higher input levels resize and or relocate the gas controls Step 4 Flame Monitoring Control System A flame m...

Страница 12: ...ower data is based on the International Standard Atmosphere ISA at Mean Sea Level MSL which means that it is valid for sea level 29 92 Hg 70 F If you are above sea level or in a hot area the propertie...

Страница 13: ...25 The total selection information you should now have blower model number motor hp motor enclosure TEFC voltage number of phases frequency rotation direction CW or CCW Air Pressure Switch The air pre...

Страница 14: ...er mm inch in 3 94 x 10 2 MJ Nm Btu ft standard 26 86 From To Multiply By kiloPascals kPa millibar mbar 10 meter m millimeter mm 1000 millibar mbar kiloPascals kPa 0 1 millimeter mm meter m 0 001 From...

Страница 15: ...ine is connected between the top of the ratio regulator and the burner body 742 Main Gas Shut Off Valve Train Eclipse strongly endorses NFPA as a minimum 790 791 Pilot Gas Valve Train Eclipse strongly...

Страница 16: ...A manual reset version requires pushing a button to transfer the contacts when the pressure set point is satisfied 840 Pressure Gauge A device to indicate pressure 940 Check Valve A check valve permi...

Страница 17: ...Notes ii...

Страница 18: ...Design Guide 310 11 14 2014 Eclipse Inc All Rights Reserved...

Отзывы: