Eclipse ETC32 – Installation Guide No. 925-1, 2/20/0  – Page 4 of 6 

Group 

Prompt 

Function Prompt 

Value or 

Selection  

Factory 

Setting 

 

Group 

Prompt 

Function 

Prompt 

Value or 

Selection  

Factory 

Setting 

 

DISPLY 

 

DECIMAL 
TEMPUNIT 
FREQ 
RATIO 2 
LANGUAGE 

 

_______ 
_______ 
_______ 
_______ 
_______ 

 

NONE 
NONE 
60 HZ 
DISABLE 
ENGLISH 

ALARMS 

A1S1TYPE 
A1S1 VAL 
A1S1 H L 
A1S1 EV 
A1S2TYPE 
A1S2 VAL 
A1S2 H L 
A1S2 EV 
A2S1TYPE 
A2S1VAL 
A2S1 H L 
A2S1 EV 
A2S2TYPE 
A2S2 VAL 
A2S2 H L 
A2S2 EV 
AL HYST 
ALMOUT1 
BLOCK 
DIAGNOST 

_______ 
_______ 
_______ 
_______ 
_______ 
_______ 
_______ 
_______ 
_______ 
_______ 
_______ 
_______ 
_______ 
_______ 
_______ 
_______ 
_______ 
_______ 
_______ 
_______ 

NONE 
90 
HIGH 
-- 
NONE 
10 
LOW 
-- 
NONE 
95 
HIGH 
-- 
NONE 

LOW 
-- 
0.1 
NoLATCH 
DISABLE 
DISABLE 

 

 

 

Ethernet 

Accessible 
via the PIE 
tool 

 

 

MAC Addr 
IP Addr  
Subnet Mask  
Default Gate  
To Email 
SMPT Addr  
Alarm 
Email Subj  

 

 

_______ 
_______ 
_______ 
_______ 
_______ 
_______ 
_______ 
_______ 

 

 

-- 
10.0.0.2 
225.225.225.0 
0.0.0.0 
-- 
0.0.0.0 
NONE 
-- 

 

 

Table 4-2. General Configuration Procedure  

Step

 

Operation 

Press 

Result 

Enter Set Up 
Mode 

Setup

Setup

 

Upper Display

 = SET  

Lower Display 

= TUNING (This is the first Set Up Group title) 

Select any Set 
Up Group 

Setup

Setup

 

Sequentially displays each Set Up Group Prompt, as listed below in the Configuration Record Sheet.   
You can also use the 

 or

 keys to scan the Set Up groups in both directions. Stop at the group 

title that describes the group of parameters you want to configure. Then proceed to the next step. 

Select a 
Function 
Parameter 

Function

Function

Function

 

Upper Display

 = the current value or selection for the first function prompt of the selected Set Up 

group. 
Lower Display 

= the first Function prompt within that Set Up group.  

Sequentially displays the other function prompts of the Set Up group you have selected. Stop at the 
function prompt that you want to change and then proceed to the next step. 

Change the 
Value or 
Selection 

 or

 

Increments or decrements the value or selection that appears for the selected function prompt. If you 
change the value or selection of a parameter while in Set Up mode then decide not to enter it, press 
the [Man/Auto] key once to recall the original value or selection.  The recall does not work for a Field 
Calibration procedure.  

Enter the Value 
or Selection 

Function

Function

Function

 

Enters value or selection made into memory after another key is pressed.  

Exit 
Configuration 

Lower

Display

Lower

Display

Lower

Display

 

Exits configuration mode and returns controller to the same state it was in immediately preceding entry 
into the Set Up mode. It stores any changes you have made.  
If you do not press any keys for 30 seconds, the controller times out and reverts to the mode and display 
used prior to entry into Set Up mode. 

 

Содержание ETC32

Страница 1: ...i n e a r m A T h e r m o c o u p l e L i n e a r V m V 2nd Current Output 12 13 10 11 12 13 S i n g l e R e l a y S S R Output 2 Alarm 2 O p e n C o l l e c t o r D u a l R e l a y 250 ohm 22 23 24 S...

Страница 2: ...on A1S1TYPE DE A1S1HL HIGH When the temperature exceeds the setpoint by the value entered for A1S1VAL then the contact closes across the current output causing the actuator to move to the low fire pos...

Страница 3: ...M UP PCT M DN OUTHiLIM OUTLoLIM I Hi LIM I Lo LIM DROPOFF DEADBAND OUT HYST FAILMODE FAILSAFE MAN OUT AUTO OUT PBorGN MINRPM _______ _______ _______ _______ _______ _______ _______ _______ _______ __...

Страница 4: ...Sheet You can also use the or keys to scan the Set Up groups in both directions Stop at the group title that describes the group of parameters you want to configure Then proceed to the next step 3 Se...

Страница 5: ...and I MIN or I RPM have been entered Use Accutune to tune the controller see product manual for detailed procedure or refer to Tuning Set Up group to manually adjust PB or GAIN RATE T and I MIN or I...

Страница 6: ...er in Hours Minutes OTR HR MN TIME REMAINING Time remaining on the Timer in Hours Minutes The O is a rotating clock face RAMPXXXM SETPOINT RAMP TIME Time remaining in the Setpoint Ramp in minutes SPN...

Страница 7: ...Offered By Power Equipment Company 2011 Williamsburg Road Richmond Virginia 23231 Phone 804 236 3800 Fax 804 236 3882 www peconet com...

Отзывы: