Eclipse ETC32 – Installation Guide No. 925-1, 2/20/0 – Page 4 of 6
Group
Prompt
Function Prompt
Value or
Selection
Factory
Setting
Group
Prompt
Function
Prompt
Value or
Selection
Factory
Setting
DISPLY
DECIMAL
TEMPUNIT
FREQ
RATIO 2
LANGUAGE
_______
_______
_______
_______
_______
NONE
NONE
60 HZ
DISABLE
ENGLISH
ALARMS
A1S1TYPE
A1S1 VAL
A1S1 H L
A1S1 EV
A1S2TYPE
A1S2 VAL
A1S2 H L
A1S2 EV
A2S1TYPE
A2S1VAL
A2S1 H L
A2S1 EV
A2S2TYPE
A2S2 VAL
A2S2 H L
A2S2 EV
AL HYST
ALMOUT1
BLOCK
DIAGNOST
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
NONE
90
HIGH
--
NONE
10
LOW
--
NONE
95
HIGH
--
NONE
5
LOW
--
0.1
NoLATCH
DISABLE
DISABLE
Ethernet
Accessible
via the PIE
tool
MAC Addr
IP Addr
Subnet Mask
Default Gate
To Email
SMPT Addr
Alarm
Email Subj
_______
_______
_______
_______
_______
_______
_______
_______
--
10.0.0.2
225.225.225.0
0.0.0.0
--
0.0.0.0
NONE
--
Table 4-2. General Configuration Procedure
Step
Operation
Press
Result
1
Enter Set Up
Mode
Setup
Setup
Upper Display
= SET
Lower Display
= TUNING (This is the first Set Up Group title)
2
Select any Set
Up Group
Setup
Setup
Sequentially displays each Set Up Group Prompt, as listed below in the Configuration Record Sheet.
You can also use the
or
keys to scan the Set Up groups in both directions. Stop at the group
title that describes the group of parameters you want to configure. Then proceed to the next step.
3
Select a
Function
Parameter
Function
Function
Function
Upper Display
= the current value or selection for the first function prompt of the selected Set Up
group.
Lower Display
= the first Function prompt within that Set Up group.
Sequentially displays the other function prompts of the Set Up group you have selected. Stop at the
function prompt that you want to change and then proceed to the next step.
4
Change the
Value or
Selection
or
Increments or decrements the value or selection that appears for the selected function prompt. If you
change the value or selection of a parameter while in Set Up mode then decide not to enter it, press
the [Man/Auto] key once to recall the original value or selection. The recall does not work for a Field
Calibration procedure.
5
Enter the Value
or Selection
Function
Function
Function
Enters value or selection made into memory after another key is pressed.
6
Exit
Configuration
Lower
Display
Lower
Display
Lower
Display
Exits configuration mode and returns controller to the same state it was in immediately preceding entry
into the Set Up mode. It stores any changes you have made.
If you do not press any keys for 30 seconds, the controller times out and reverts to the mode and display
used prior to entry into Set Up mode.