USERS’ MANUAL

JAN 2017 Rev 1.1  |  © Copyright 2017 Eclipse Tools-All rights reserved.

Eclipse Enterprises, Inc.

13302 Chula Road, Amelia Court House, VA 23002

Tel. 804-561-2610     Fax. 804-561-2642

[email protected]

www.eclipsetools.com

Hand-held TDR  

/

  

Item# 902-558

V.O.P

LIGHT

START

OK / 

MENU

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 

Содержание ECL-1000

Страница 1: ...terprises Inc 13302 Chula Road Amelia Court House VA 23002 Tel 804 561 2610 Fax 804 561 2642 salessupport eclipsetools com www eclipsetools com Hand held TDR Item 902 558 V O P LIGHT START OK MENU Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Страница 2: ...al wear and tear of mechanical components Eclipse Tools will provide an estimate of repair costs and obtain authorization before commencing the work For service contact the distributor or reseller from whom this instrument was originally purchased Limited Warranty and Repair Product Overview Safety Information Physical Characteristics Operation Installing Batteries Turning the instrument On Off Dis...

Страница 3: ...jury See the manual for details Caution Risk of damage or destruction to instrument Risk of electric shock Risk of damage to instrument from static discharge Conforms to European Union directives Do not put products containing circuit boards into the garbage This instrument contains parts that can be damaged by static discharge This instrument should not be connected to any energized circuits Conn...

Страница 4: ...teries Turning the instrument on off Use only two AA batteries correctly installed to supply power to instrument Do not use instrument with the battery door open removed To prevent unreliable measurement replace the battery as soon as low indication shows on the display Press and hold the Power Button which turns this instrument on and off See Figure 4 0 20 40 100 Figure 1 Figure 2 Figure 3 Figure 4...

Страница 5: ... on page 10 LIGHT LIGHT LIGHT START OK Condition ESC Click Press Hold START OK Start the test OK and Select the List Return to the Main screen Return to Previous menu Caution The TDR operates only on cables that have two conductors When testing cables connect the instrument only to de energized circuit Do not connect this instrument directly to live wire If this instrument detect above 250mV 500kH...

Страница 6: ... V O P function to find the V O P for a known length of cable Set V O P value Save position Saved value Turn on instrument Click and you can see Manual V O P menu see Figure 8 You can adjust your V O P value with Navigation buttons After adjustment click to save Cursor will move to save position You can choose your V O P value position with Navigation buttons After set click to save position Figure...

Страница 7: ... OK Choose USER V O P LIST and click You can choose your saved V O P list with navigation button Select your list and press to set up This instrument support total 8 user settable V O P list START OK V O P LIGHT START OK See Velocity of Propagation section page 11 Figure 13 Figure 14 Choose your unit and click to save START OK START OK Choose your time and click to save ...

Страница 8: ...9 In 0 1 step 0 3 of reading 1cm 1 0 of reading 3km Min distance 5m This instrument requires 2 LR6 AA type batteries To prevent unreliable test results replace the battery as soon as the battery icon shows no bars See Installing Batteries Before you remove the battery door make sure disconnect the cable If moisture gets inside the instrument let the instrument dry at ordinary temperature for 24 ho...