background image

ECL-IP3DPT

User

’s Manual 

Version 1.0.0

Содержание ECL-IP3DPT

Страница 1: ...ECL IP3DPT User s Manual Version 1 0 0 ...

Страница 2: ...ur Network camera This user s manual is designed to be a reference tool for your system Please read the following safeguard and warnings carefully before you use this series product Please keep this user s manual well for future reference ...

Страница 3: ...on Please install the proper power cut off device during the installation connection Always follow the instruction guide the manufacturer recommended 4 Qualified engineers needed All the examination and repair work should be done by the qualified service engineers We are not liable for any problems caused by unauthorized modifications or attempted repair 5 Environment This series network camera sh...

Страница 4: ...t do not touch the enclosure when you are installing the device or clean the enclosure when you are doing maintenance work Please use professional optical clean method to clean the enclosure Improper enclosure clean method such as use cloth may result in poor IR effect of camera with IR function 7 Accessories Be sure to use all the accessories recommended by manufacturer Before installation please...

Страница 5: ...4 2 2 Framework and Dimension 4 3 Device Installation 6 3 1 Installation Steps 6 3 2 Restore Factory Default Setup Introduction 8 4 Quick Configuration Tool 9 4 1 Overview 9 4 2 Operation 9 5 Web Operation 11 5 1 Network Connection 11 5 2 Login and Main Interface 11 6 FAQ 13 Appendix Toxic or Hazardous Materials or Elements 14 ...

Страница 6: ... Support central server backup function in accordance with your configuration and setup in alarm or schedule setting Support record via Web and the recorded file are storage in the client end PC Support network storage function such as FTP Network Monitor Network camera supports one channel video data transmit to network terminal and then decode Delaying time is within 270ms network bandwidth supp...

Страница 7: ...al Low noise anti blur Manual Adjustable range from 1 3 to 1 10000 Video Compression Standard H 264 H 264H MJPEG Video Frame Rate PAL Main stream 1280 960 25fps extra stream 704 576 25fps PAL Main stream 1920 1080 25fps extra stream 704 576 25fps PAL Main stream 2048 1536 20fps extra stream 704 576 20fps Main stream 1290 1080 25fps extra stream 704 576 25fps NTSC Main stream 1280 960 30fps extra s...

Страница 8: ...rk 1 ch 10 100 M Ethernet RJ45 port Network Protocol HTTP TCP IP ARP IGMP ICMP RTSP RTP UDP RTCP SMTP FTP D HCP DNS DDNS PPPOE UPNP NTP Bonjour SNMP Platform Interface Standard Default ONVIF GB28181 Remote Operation Monitor system setup log information maintenance upgrade and etc AUX Interfa ce Restore Default Setup Built in Reset button General Parameter Power DC12V power and PoE Power Consumptio...

Страница 9: ...1 Please refer to the following sheets for detailed information Sheet 2 1 No Port Name Connector Note 4 LAN Network port Ethernet To connect to standard Ethernet 5 DC12V DC 12V power To connect to DC12V power supply Sheet 2 2 2 2 Framework and Dimension Component Component Name Component 1 Device lens Component 2 Dome enclosure ...

Страница 10: ...5 Please refer to the following two figures for dimension information The unit is mm See Figure 2 2 and Figure 2 3 Figure 2 2 Dimension illustration 1 Figure 2 3 Dimension illustration 2 ...

Страница 11: ...he cable exit when you install the device Step 2 Adjust the device installation pedestal to the proper position and then line up the three screw holes in the device pedestal to the three plastic expansion bolt holes in the installation position Put the three self tapping screws in the three plastic expansion bolts and lock them firmly Step 3 Aim the three slots on the dome body to the three corres...

Страница 12: ...the cable exit port on the rear of the dome The GND screw uses the M2X5 pan screw See Figure 3 3 for more information Figure 3 3 Note This series product supports two cable exits One is from the bottom and the other is from the side Please refer to the following figure for cable exit from the side information ...

Страница 13: ...troduction Important Please use RESET button when device is running Step1 Take down the dome from the installation pedestal Step2 Unscrew two screws Step3 Long press the RESET button to complete the reset function See Figure 3 4 Figure 3 4 ...

Страница 14: ...wn as in Figure 4 1 In the device list interface you can view device IP address port number subnet mask default gateway MAC address and etc Figure 4 1 Search interface Select one IP address and then right click mouse you can see an interface is shown as in Figure 4 2 Select the Open Device Web item you can go to the corresponding web login interface Figure 4 2 Search interface 2 If you want to mod...

Страница 15: ...to login Please note the port information here shall be identical with the port value you set in TCP port in Web Network interface Otherwise you cannot login the device If you are using device background upgrade port 3800 to login other setups are all invalid Figure 4 3 Login prompt After you logged in the configuration tool main interface is shown as below See Figure 4 4 Figure 4 4 Main interface...

Страница 16: ... the PC and the network camera respectively Network camera default IP address is 192 168 1 108 Subnet mask is 255 255 255 0 Gateway is 192 168 1 1 Use order ping network camera address to check connection is OK or not 5 2 Login and Main Interface Open IE and input network camera address in the address bar See Figure 5 1 Figure 5 1 IP address The login interface is shown as below See Figure 5 2 Ple...

Страница 17: ...ogin After you successfully logged in please install WEB plug in unit Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction See Figure 5 3 Figure 5 3 Web monitoring window ...

Страница 18: ...er if you can not install the client end or can not view after the installation We recommend the win2000sp4 OS or install the client end of the low version The Active X control is blocked The display card version shall be dx8 1 or higher Network connection error occurred Invalid network setup Invalid user name or password I can not play the download file There is no player There is no DX8 1 or hig...

Страница 19: ... toxic or hazardous substance or elements contained in products will not leak or mutate so that the use of these substances or elements will not result in any severe environmental pollution any bodily injury or damage to any assets The consumer is not authorized to process such kind of substances or elements please return to the corresponding local authorities to process according to your local go...

Отзывы: