2. WARNINGS

 

It is important to read this manual carefully before using the device 

ECLERIS will not be held responsible for damage that can occur to the equipment due to not following the instructions or not observing the following 
criteria: 

 

Keep the equipment out of children reach. 

 

Do not install the equipment next to heat sources, such as heaters  

 

Install the equipment on a firm horizontal surface, in a well-ventilated area. 

 

Protect the equipment and accessories from direct solar light, dust, humidity and vibrations or excessive banging. 

 

Equipment not appropriate to be used near or around flammable anestheticmixture with air, oxygen or nitrous oxide. 

 

The equipment does not need sterilization. 

 

Do not put any container with liquids on top of the device. 

 

Main power cord and PROCAM HD cable are resistant to deformations and mechanical tensions however do not damage or avoid violent 
shocks to the cables. 

 

Do not use the equipment during electrical storms. 

 

Unplug the equipment when it is not being used. 

 

This equipment has to be connected to ground through a ground conductor in the power cable. This ground connection is essential for the 
safe use of the equipment 

 

Do not connect the equipment to devices that do not comply with IEC60601-1ed 3.0 or later. 

 

The device is provided with a connectable power cable that assures proper electrical isolation.If it needs to be replaced, the replacement 
will not be longer that the original cable and it needs to be certified under IEC 60245-1 or IEC 60227-1. 

 

In case of interference with other electro medical or electric equipment, we recommend increasing the distance between PROCAM HD and 
the other equipment to minimize these effects. 

 

Do not open the equipment. Maintenance and repairs must be done by ECLERIS or an authorized company. ECLERIS will not be responsible 
for the consequences of repairs or maintenance carried out by non-authorized personal.  

 

In case of any problem, disconnect the power cable 

 

The device must be used only by personnel informed of all this warnings. 

 

This instruction manual must be kept together with the equipment for future reference. If the equipment should be sold or donated this 
manual must be enclosed. 

 

Any use outside of the manufacturer specific intent use, will exclude ECLERIS of all liability. 

 

If by any of the following: 

 

Inadequate use of the equipment. 

 

Failure to use the instruction manual. 

 

Bad maintenance and care of the equipment. 

 

Repair or manipulation by unauthorized personal. 

…personal or material damage is produced to a third party, ECLERIS, the manufacturer and sales agent of this equipment, will not assume 
reasonability for said damage. 

The device should never be discarded with the household waste. Please check local regulations for electronic components disposal or 
recycling. It is the user’s responsibility to deliver the system to the proper location for disposal or recycle of electrical and electronic 
device  

 

Содержание PROCAM HD

Страница 1: ...INMANUUIN121 M USO VI340 HC118G2 ING USA V 2016 10 06 DOCX PROCAMHD CCDCAMERA AND CONSOLE VI340 HC118...

Страница 2: ...tive MEDES Ltd UK 5 Beaumont Gate Shenley Hill Radlett Herts WD7 7AR England Tel 423 663 169205 Tel Fax 44 1923 859 810 e mail medes arazygroup com Ecleris PROCAM cameras are CE approved complying wit...

Страница 3: ...2 PROCAM HD Camera 5 4 INSTALLATION 5 4 1 COUPLING TO ECLERIS EVERLUX LIGHT SOURCE 6 5 REVISION AND OPERATION 9 5 1 REVISION 9 5 2 OPERATION 9 5 2 1 White balance 10 5 2 2 Window Function 10 5 2 3 Fu...

Страница 4: ...up Enviroment transport conditions Pressure Limits Humidity Limits Camera connection Window Function White Balance Anti Moir Function CE Mark Manufacturer Information Name Address Type BF Do not disc...

Страница 5: ...s proper electrical isolation If it needs to be replaced the replacement will not be longer that the original cable and it needs to be certified under IEC 60245 1 or IEC 60227 1 In case of interferenc...

Страница 6: ...ng flexible fiber endoscopes and Windows minimizes the light saturation when using small diameter endoscopes PROCAM HD power supply console was specifically designed to be used together with High Defi...

Страница 7: ...X 4 3 3 Components 3 3 1 PROCAM HD Console 3 3 1 1 Front Panel 1 ON OFF button 2 PROCAM HD Connector 3 3 1 2 Rear Panel 1 Power connector 2 Equal potential Ground connection 3 Video output in high def...

Страница 8: ...or later Use the endoscope in accordance with IEC60601 2 18 1 Unpack the device with care 2 Place the PROCAM HD console on a solid surface 3 If the building structure has equipotential grounding conne...

Страница 9: ...x light source you will need a 2 5 millimeters Allen key With this Allen key unscrew the two screws at the bottom of the PROCAM HD console as it is shown in the picture Doing so two heads of screws wi...

Страница 10: ...in place into the holes of the ECLERIS Everlux light source base you need to slightly push back the PROCAM HD console in order to attach it completely to the ECLERIS Everlux light source Finally to e...

Страница 11: ...Everlux light source after removing the Everlux handle on top of the unit In order to avoid both the use of two electrical power sockets to supply both devices and also the use of many cables ECLERIS...

Страница 12: ...to the electrical socket through the power cable supplied by ECLERIS The electrical supply has to be done at electrical socket without power adapters The equipment must be used only in places where t...

Страница 13: ...ctivated only the surface that contains image information is used to control the camera sensitivity this way the camera adjustment and the image contrast is optimized even for very thin optics and sho...

Страница 14: ...r Turn off Anti Moir Deactivated Blinking Anti Moir level 1 Turn on Anti Moir level 2 To active the first level of filtration press the Anti Moir button on the camera once When the first level is acti...

Страница 15: ...ially alcohol when the unit is hot Do not turn the equipment on until one 1 hour after cleaning process We recommend cleaning the external surface of the equipment every 15 days Do not sterilize any p...

Страница 16: ...NMANUUIN121 M USO VI340 HC118G2 ING USA V 2016 10 06 DOCX 13 Only use fuses as shown at the rear side of the PROCAM HD console and certified by IEC60127 4 Screw again the knobs 5 Connect the power cor...

Страница 17: ...ION 1920 H x 1080 V 60 fps SENSOR CMOS THERMAL PROTECTION Overheating automatic shutdown of power supply OPERATING CONDITIONS 10 40 C 35 75 relative humidity 700 1060 hPa STORAGE AND TRANSPORT 30 45 C...

Страница 18: ...nput change the connection to another input Monitor off Turn the monitor on Monitor disconnected Plug the monitor to the PROCAM HD console through the provided cord Monitor in wrong video mode Set the...

Страница 19: ...nsible for damage caused during the transportation due to improper packaging 10 WARRANTY ECLERIS declares that the PROCAM HD has passed our Quality Control and no defects have been found in its manufa...

Отзывы: